【国外标准】 Standard Performance Specification for Cerebral Stereotactic Instruments (Withdrawn 2017)
本网站 发布时间:
2024-02-28
- ASTM F1266-89(2008)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
The purpose of a stereotactic apparatus is to guide the advance of an electrode or other probe accurately and in a controlled fashion to a given point in space, relative to the apparatus, to the stereotactic target. Thus, when the apparatus is attached to the skull, the electrode or probe can be advanced to a given geographical point within the cranial cavity, near the base of the skull or in the spinal canal. As generally employed, the ventricles or cavities within the brain or other neurosurgical landmarks are identified roentgenographically by other means and, by consulting an atlas or other table, the mean distance and direction between the visualized landmark and a given anatomical target are measured. The electrode or probe is then inserted to the stereotactic target, that is, the point in space which is calculated from the distance and direction between the visualized landmark and the desired target in relation to the coordinate system of the stereotactic apparatus. It is recognized that there is considerable anatomical variability in the size and shape of the central nervous system so that the target point that is identified from the atlas or table is only approximate. Usually, where possible, physiological verification may also be obtained. One must distinguish between the anatomical accuracy, which is inexact because of the variability of brains, and the mechanical accuracy, which is a function of the precision of the stereotactic instrument. The requirements set forth herein are concerned only with the mechanical accuracy of stereotactic instruments. It is also recognized that once minimum standards for mechanical accuracy have been obtained, increased mechanical precision will not necessarily lead to increased anatomical precision. 1.1 This specification covers stereotactic instruments used by neurosurgeons to assist in the placement of probes, such as cannulae, needles, forceps, or electrodes or to direct radiation into brain regions or anatomical targets that are not visible on the surface. The general location of these regions is determined by measurements from landmarks visualized by X ray or other means, such measurements being based on atlases derived from anatomical studies and autopsy. Because of the anatomical variability, more precise location in any single patient may be determined by physiological responses in that patient. The degree of success in stereotactic surgery depends upon the experience of the surgeon as well as the precision of the stereotactic instrument. Nevertheless, minimum standards of accuracy for stereotactic instruments that are within the range of variability of human anatomy must be maintained. 1.2 For the purpose of this specification, a stereotactic instrument is a guiding device used in human neurosurgery for the purpose of directing an instrument or treating modality to a specific point within the brain by radiographic or other visualization of landmarks. 1.3 Stereotactic instruments must be constructed to afford the surgeon reliably reproducible accuracy in placing instruments into target areas. Proper positioning of the probe is often verified by X rays to control errors in calculation and to correct deflection of the probe during insertion. Physiological parameters may be used to further define the optimal target. 1.4 At the present time, stereotactic instruments are used most frequently, but not exclusively in the following operations. The list is presented only to present examples and should not be construed to restrict advances or developments of new procedures. For some applications it is not required to hit a point in space, but to hit a volume or make a lesion within a mass. For that purpose, devices other than those covered by this specification may be employed, but should be restricted to such uses: 1.4.1 Thalamotomy for parkinsonism and other types of tremor, 1.4.2 Electrode implantation for epilepsy, 1.4.3 Needle or magnetic insertion, or both, for aneurysm thrombosis, 1.4.4 Thalamic or subthalamic operations for dystonia, 1.4.5 Thalamic or subthalamic operations for involuntary movements such as chorea or hemiballismus, 1.4.6 Ablation of deep cerebellar nuclei for spasticity, 1.4.7 Cingulotomy and thalamic or subthalamic surgery for pain, 1.4.8 Mesencephalotomy or tractotomy for pain, 1.4.9 Ablations of subcortical temporal lobe structures for treatment of epilepsy, 1.4.10 Psychosurgical procedures, 1.4.11 Implantation of depth stimulating electrodes for pain, 1.4.12 Insertion of forceps or needle for obtaining biopsy specimens, 1.4.13 Foreign body removal, 1.4.14 Implantation of radioactive material, and 1.4.15 Biopsy or treatment of tumors. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM F1266-89(2008)
标准名称:
Standard Performance Specification for Cerebral Stereotactic Instruments (Withdrawn 2017)
英文名称:
Standard Performance Specification for Cerebral Stereotactic Instruments (Withdrawn 2017)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 4123.1-2008 Mobile waste containers Containers with two wheels and a capacity up to 400 L for lifting devices - Dimensions and design
- AS 4123.7-2006 (R2017)/Amdt 1-2008 Mobile waste containers Colours, markings, and designation requirements
- AS 4145.1-2008/Amdt 1-2009 Locksets and hardware for doors and windows Glossary of terms and rating system
- AS 4156.3-2008/Amdt 1-2009 Coal preparation Magnetite for coal preparation plant use - Test methods (Reconfirmed 2020)
- AS 4326-2008 The storage and handling of oxidizing agents
- AS 4457.2-2008 Earth-moving machinery - Off-the-road wheels, rims and tyres - Maintenance and repair Tyres
- AS 4758.1-2008/Amdt 1-2009 Personal flotation devices General requirements
- AS 4758.2-2008 Personal flotation devices Materials and components - Requirements and test methods
- AS 4758.3-2008 Personal flotation devices Test methods
- AS 4772-2008 Earth-moving machinery - Quickhitches for excavators and backhoe loaders
- AS 4822-2008/Amdt 1-2010 External field joint coatings for steel pipelines
- AS 4992.1-2006/Amdt 1-2008 Ceramic tiles - Grouts and adhesives Terms, definitions and specifications for adhesives
- AS 5101.4-2008 Methods for preparation and testing of stabilized materials Unconfined compressive strength of compacted materials
- AS 5200.053-2008 Plumbing and drainage products Stainless steel pipes and tubes for pressure applications
- AS 62040.2-2008 Uninterruptible power systems (UPS) Electromagnetic compatibility (EMC) requirements