【国外标准】 Standard Test Method for Automated Analyses of Cells—the Electrical Sensing Zone Method of Enumerating and Sizing Single Cell Suspensions
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
3.1 The electrical sensing zone method for cell counting is used in tissue culture, government research, and hospital, biomedical, and pharmaceutical laboratories for counting and sizing cells. The method may be applicable to a wide range of cells sizes and cell types, with appropriate validation (10).3.2 The electrical sensing zone methodology was introduced in the mid-1950s (9). Since this time, there have been substantial improvements which have enhanced the operator's ease of use. Among these are the elimination of the mercury manometer, reduced size, greater automation, and availability of comprehensive statistical computer programs.3.3 This instrumentation offers a rapid result as contrasted to the manual counting of cells using the hemocytometer standard counting chamber. The counting chamber is known to have an error of 10 to 30 %, as well as being time-consuming (11). In addition, when counting and sizing porcine hepatocytes, Stegemann et al concluded that the automated, electrical sensing zone method provided greater accuracy, precision, and speed, for both counts and size, compared to the conventional microscopic or the cell mass-based method (7).1.1 This test method, provided the limitations are understood, covers a procedure for both the enumeration and measurement of size distribution of most all cell types. The instrumentation allows for user-selectable cell size settings and is applicable to a wide range of cell types. The method works best for spherical cells, and may be less accurate if cells are not spherical, such as for discoid cells or budding yeast. The method is appropriate for suspension as well as adherent cell cultures (1).2 Results may be reported as number of cells per milliliter or total number of cells per volume of cell suspension analyzed. Size distribution may be expressed in cell diameter or volume.1.2 Cells commonly used in tissue-engineered medical products (2) are analyzed routinely. Examples are chondrocytes (3), fibroblasts (4), and keratinocytes (5). Szabo et al. used the method for both pancreatic islet number and volume measurements (6). In addition, instrumentation using the electrical sensing zone technology was used for both count and size distribution analyses of porcine hepatocytes placed into hollow fiber cartridge extracorporeal liver assist systems. In this study (7), and others (6, 8), the automated electrical sensing zone method was validated for precision when compared to the conventional visual cell counting under a microscope using a hemocytometer. Currently, it is not possible to validate cell counting devices for accuracy, since there not a way to produce a reference sample that has a known number of cells. The electrical sensing zone method shall be validated each time it is implemented in a new laboratory, it is used on a new cell type, or the cell counting procedure is modified.1.3 Electrical sensing zone instrumentation (commonly referred to as a Coulter counter) is manufactured by a variety of companies and is based upon electrical impedance. This test method, for cell counting and sizing, is based on the detection and measurement of changes in electrical resistance produced by a cell, suspended in a conductive liquid, traversing through a small aperture (see Fig. 1(9)). When cells are suspended in a conductive liquid, phosphate-buffered saline for instance, they function as discrete insulators. When the cell suspension is drawn through a small cylindrical aperture, the passage of each cell changes the impedance of the electrical path between two submerged electrodes located on each side of the aperture. An electrical pulse, suitable for both counting and sizing, results from the passage of each cell through the aperture. The path through the aperture, in which the cell is detected, is known as the “electronic sensing zone.” This test method permits the selective counting of cells within narrow size distribution ranges by electronic selection of the generated pulses. While the number of pulses indicates cell count, the amplitude of the electrical pulse produced depends on the cell's volume. The baseline resistance between the electrodes is due to the resistance of the conductive liquid within the boundaries of the aperture. The presence of cells within the “electronic sensing zone” raises the resistance of the conductive pathway that depends on the volume of the cell. Analyses of the behavior of cells within the aperture demonstrates that the height of the pulse produced by the cell is the parameter that most nearly shows proportionality to the cell volume.1.4 Limitations are discussed as follows:1.4.1 Coincidence—Occasionally, more than a single cell transverses the aperture simultaneously. Only a single larger pulse, as opposed to two individual pulses, is generated. The result is a lower cell count and higher cell volume measurement. The frequency of coincidence is a statistically predictable function of cell concentration that is corrected by the instrument. This is called coincidence correction (8). This phenomenon may be reduced by using lower cell concentrations.1.4.2 Viability—Electrical sensing zone cell counting enumerates both viable and nonviable cells and cannot determine percent viable cells. A separate test, such as Trypan blue, is required to determine percent viable cells.1.4.3 Cell Diameter—This is a function of the size range capability of the aperture size selected. Measurements may be made in the cell diameter range of 0.6 μm to 1200 μm. Setting the counting size range on the instrument can affect the test results, especially if the cell size has a large distribution, and should be carefully controlled to help achieve repeatability.1.4.4 Size Range of the Aperture—The size range for a single aperture is proportional to its diameter. The response has been found to depend linearly on diameter over a range from 2 % to 80 % of the diameter. However, the aperture tube may become prone to blockage at levels greater than 60 % of diameter. Therefore, the practical operating range of the aperture is considered to be 2 % to 60 % of the diameter.1.4.5 Humidity—10 % to 85 %.1.4.6 Temperature—10 °C to 35 °C.1.4.7 Electrolyte Solution—The diluent for cell suspension shall provide conductivity and have minimal effect on cell size. The electrolyte of choice is commonly phosphate-buffered saline.
标准号:
ASTM F2149-16
标准名称:
Standard Test Method for Automated Analyses of Cells—the Electrical Sensing Zone Method of Enumerating and Sizing Single Cell Suspensions
英文名称:
Standard Test Method for Automated Analyses of Cells—the Electrical Sensing Zone Method of Enumerating and Sizing Single Cell Suspensions标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 推荐标准
- AS 1038.16-1996 Coal and coke - Analysis and testing Assessment and reporting of results
- AS 1085.16-1995 Railway permanent way material Cast sleeper plates
- AS 1141.16-1995 Methods for sampling and testing aggregates Angularity number
- AS 1807.16-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of sound level in cleanrooms
- AS 2001.7.16-1983 Methods of test for textiles Quantitative analysis of fibre mixtures - Binary mixtures of jute and certain animal fibres (method of determining the nitrogen content)
- AS 2149-2003 Starter batteries - Lead-acid
- AS 2362.16-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices Impact test
- AS 2550.16-1997 Cranes- Safe use Mast climbing work platforms
- AS 3730.16-1991 Guide to the properties of paints for buildings Latex - Timber finish - Exterior
- ASTM D3550/D3550M-17 Standard Practice for Thick Wall, Ring-Lined, Split Barrel, Drive Sampling of Soils
- ASTM D3551-17 Standard Practice for Laboratory Preparation of Soil-Lime Mixtures Using Mechanical Mixer
- ASTM D3552-17 Standard Test Method for Tensile Properties of Fiber Reinforced Metal Matrix Composites
- ASTM D3554-20e1 Standard Specification for Track-Resistant Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 °C Operation
- ASTM D3556-23 Standard Guide for Deposition on Glassware During Mechanical Dishwashing
- ASTM D3557-17 Standard Test Methods for Cadmium in Water