
【国外标准】 Standard Test Method for Evaluating the Resistance of the Surface of Wet Blue and Wet White to the Growth of Fungi in an Environmental Chamber
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
6.1 The environmental chamber method is an accelerated test for determining the resistance of Wet Blue and Wet White to the growth of fungi, the causal agent of mold. See Test Method D3273.3,46.2 The environmental chamber method is useful in estimating the performance of fungicides and should assist in the prediction of storage time before fungal growth begins.6.3 The environmental chamber method duplicates the natural environment in which Wet Blue or Wet White is inoculated with fungal spores and subsequently disfigured or discolored by fungi.6.4 The environmental chamber method measures the resistance of the treated Wet Blue or Wet White to the germination of spores and subsequent vegetative growth that spreads over the surface of a comparatively large Wet Blue or Wet White specimen over a period of four weeks.6.5 The environmental chamber can be kept inoculated with fungi representative of those found in tanneries by adding samples of Wet Blue and Wet White with fungal growth from currently operating tanneries.6.6 Control specimens of Wet Blue and Wet White without fungicide treatment can be added to the chamber periodically to increase levels of fungal growth in the chamber.6.7 Leaching of fungicide from the test specimen into the agar often causes a zone of inhibition of fungal growth in the Petri dish test, but in the environmental chamber any leaching of fungicide from the test specimen drips into the water contained in the chamber and thus does not cause the types of false readings observed in the Petri dish test.1.1 This environmental chamber method measures the resistance of the treated Wet Blue and Wet White to the germination of spores and subsequent vegetative growth over a period of four weeks. The test method is useful in estimating the performance of fungicides and should assist in the prediction of storage time of Wet Blue and Wet White before fungal growth begins. The apparatus is designed so it can be easily built or obtained by any interested party and duplicate the natural environment in which Wet Blue and Wet White is inoculated with fungal spores. Spores that germinate on untreated or treated Wet Blue and Wet White can produce fungal growth, resulting in disfigurement or discoloration, or both, of the Wet Blue and Wet White.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D7584-16(2021)
标准名称:
Standard Test Method for Evaluating the Resistance of the Surface of Wet Blue and Wet White to the Growth of Fungi in an Environmental Chamber
英文名称:
Standard Test Method for Evaluating the Resistance of the Surface of Wet Blue and Wet White to the Growth of Fungi in an Environmental Chamber标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- INCITS 103-1983 (S2021) Unrecorded Magnetic Tape Minicassette For Information Interchange, Coplanar 3.81 mm (0.150 Inch)
- INCITS 121-1984 (S2021) Two-Sided Unformatted 8-Inch (200 MM) Double Density Flexible Disk Cartridge (For 13262 FTPR Two-headed Application) (Combined with Project 287)
- INCITS 124.1-1985 (S2021) FORTRAN Binding of Graphical Kernel System (GKS)
- INCITS 125-1985 (S2021) Two-Sided, Double-Density, Unformatted 5.25 Inch (130 mm) 48-tpi (1.9 tpmm) Flexible Disk Cartridge for 7958 BPR Use
- INCITS 164-1990 (S2021) Unrecorded Magnetic Tape Cassette for Information Interchange 3.81 mm (0.150 In), 252 to 394 ftpmm (6400 to 10000 ftpi)
- INCITS 180-1990 (S2021) Magnetic Tape and Cartridge for Information Interchange, 18-Track, Parallel, 12.65mm (1/2 in.) 1491 cpmm (37 871 cpi) Group-Coded, Requirements for Recording
- INCITS 181-1990 (S2021) Recorded Magnetic Tape Cartridge for Information Interchange 0.500 in, 22 and 48 Tracks Serial Serpentine, 6 667 and 10 000 bpi
- INCITS 22-1983 (S2021) Recorded Magnetic Tape for Information Interchange (800 CPI, NRZI)
- INCITS 232-1996 (S2021) SCSI-2 Common Access Method Transport and SCSI Interface Module
- INCITS 243-1996 (S2021) Serial Magnetic Tape Cartridge for Information Interchange, 26 Tracks, 0.250 in (6.35 mm), 16 000 bpi (630 bpmm), Streaming Mode, Group Code Recording
- INCITS 248-1996 (S2021) Abstract Test Suite for FDDI Physical Layer Protocol Conformance Testing (FDDI PHY ATS)
- INCITS 250-1996 (S2021) Recorded Magnetic Tape Mini-Cartridge for Information Interchange, 0.250 in (630 mm)12 and 24 Track,10000 bpi (394 bpmm) GCR
- INCITS 269-1996 (S2021) SCSI-3 Fibre Channel Protocol (FCP)
- INCITS 282-1996 (S2021) Magnetic Tape Cartridge for Information Interchange, 0.50 in (12.65 mm) Serial Serpentine, 128-Track, 62 500 bpi (2460 bpmm), DLT3 Format
- INCITS 293-1996 (S2021) Serial Storage Architecture - Physical Layer 1 (SSA-PH1)