
【国外标准】 Standard Specification for Closed Rib Steel Pipe with Diameter of 36 in. [900 mm] or Less, Polymer Precoated for Sewers and Drains (Withdrawn 2012)
本网站 发布时间:
2024-02-28
- ASTM A1019/A1019M-01(2007)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This specification deals with polymer precoated, closed rib steel pipes intended for use for storm water drainage, underdrains, the construction of culverts, and similar uses. The pipes covered here are not normally used for conveyance of sanitary or industrial wastes, and are of Type ICR, which have a full circular cross section and single thickness of smooth sheet, fabricated with outwardly projecting closed helical ribs. The steel sheet used for fabricating the pipe has a polymer protective coating over a zinc metallic coating. This specification does not include requirements for bedding, backfill, or the relationship between earth cover load and sheet thickness of the pipe. Pipes shall conform to dimensional and physical requirements such as nominal inside diameter, closed rib profile size, rib width, depth and spacing, sheet thickness, and lock seam tensile strength per unit width. Damaged coatings shall be repaired by paints containing zinc dust, metallizing coatings, or polymer coatings of similar characteristics.1.1 This specification covers polymer precoated, closed rib steel pipe, intended for use for storm water drainage, under-drains, the construction of culverts, and similar uses. Pipe covered by this specification is not normally used for the conveyance of sanitary or industrial wastes. The steel sheet used in fabrication of the pipe has a polymer protective coating over a metallic coating of zinc.1.2 The polymer precoating provides extra protection of the base metal against corrosion or abrasion, or both, in addition to that provided by the metallic coating. Severe environments are likely to cause corrosion problems to accessory items such as coupling band hardware that does not have a polymer coating unless supplemental protection is provided. Additional protection for polymer precoated steel pipe is available by use of coatings applied after fabrication of the pipe as described in Specification A 849.1.3 This specification does not include requirements for bedding, backfill, or the relationship between earth cover load and sheet thickness of the pipe. Experience with drainage products has shown that successful performance depends upon the proper selection of rib depth, sheet thickness, type of bedding and backfill, controlled manufacture in the plant, and care in installation. The installation procedure is described in Practice A 798/A 798M.1.4 This specification is applicable to orders in either inch-pound units as A 1019, or in SI units as A 1019M. Inch-pound units and SI units are not necessarily equivalent. SI units are shown in brackets in the text for clarity, but they are the applicable values when the material is ordered to A 1019M.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM A1019/A1019M-01(2007)
标准名称:
Standard Specification for Closed Rib Steel Pipe with Diameter of 36 in. [900 mm] or Less, Polymer Precoated for Sewers and Drains (Withdrawn 2012)
英文名称:
Standard Specification for Closed Rib Steel Pipe with Diameter of 36 in. [900 mm] or Less, Polymer Precoated for Sewers and Drains (Withdrawn 2012)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM A1018/A1018M-23a Standard Specification for Steel, Sheet and Strip, Heavy-Thickness Coils, Hot-Rolled, Carbon, Commercial, Drawing, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved Formability, and Ultra-High Strength
- 下一篇: ASTM A102-04(2019) Standard Specification for Ferrovanadium
- 推荐标准
- ANSI INCITS 422-2007 Application Profile for Commercial Biometrical Physical Access Control
- ANSI INCITS 61-1986 (R2007) Geographic Point Locations for Information Interchange, Representation of (formerly ANSI X3.61-1986 (R1997))
- ANSI X9.44-2007 (R2017) Key Establishment Using Integer Factorization Cryptography
- ANSI X9.82: Part 3-2007 (R2017) Financial Services - Random Number Generation Part 3: Deterministic Random Bit Generators
- AS 1019-1985 Internal combustion engines - Spark emission control devices
- AS 1019-2000 Internal combustion engines - Spark emission control devices
- AS 1141.34-2007 Methods for sampling and testing aggregates Organic impurities other than sugar
- AS 1301.P201m-1986 Methods of test for pulp and paper (metric units) Kappa number of pulp
- AS 1301.P414m-1986 Methods of test for pulp and paper (metric units) Conditioning of paper for testing
- AS 1358-2004 (R2016)/Amdt 1-2007 Bursting discs and bursting disc devices - Application, selection and installation
- AS 1418.10(Int)-2004/Amdt 2-2007 Cranes, hoists and winches Elevating work platforms
- AS 1418.11-2007 Cranes, hoists and winches Vehicle-loading cranes
- AS 1418.19-2007 Cranes, hoists and winches Telescopic handlers
- AS 1444-2007 (R2017)/Amdt 1-2008 Wrought alloy steels - Standard, hardenability (H) series and hardened and tempered to designated mechanical properties
- AS 1742.15-2007 Manual of uniform traffic control devices Direction signs, information signs and route numbering