
【国外标准】 Standard Practice for Application of CaF2(Mn) Thermoluminescence Dosimeters in Mixed Neutron-Photon Environments
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Electronic devices are typically tested for device response to gamma radiation in pure gamma-ray fields. Testing electronic device response against neutrons is more complex since there is invariably a gamma-ray component in addition to the neutron field. The gamma-ray response of the electronic device is typically subtracted from the overall response to find the device response to neutrons. This approach to the testing requires a determination of the gamma-ray exposure in the mixed field. To enhance the neutron effects, the radiation field is sometimes selected to have as large a neutron component as possible.4.2 CaF2(Mn) TLDs are often used to monitor the gamma-ray dose in mixed neutron/gamma radiation fields. Since the dosimeters are exposed along with the device under test to the mixed field, their response must be corrected for neutrons. In a field rich in neutrons, the uncertainty in the interpretation of the TLD response grows. In fields with relatively few neutrons, the total TLD response may be used to make a correction for gamma response of the device under test. Under this condition, the relative uncertainty in the TLD neutron response is not likely to drive the overall uncertainty in the correction to the electronic device response.4.3 This practice gives a means of estimating the response of CaF2(Mn) TLDs to neutrons. This neutron response is then subtracted from the measured response to determine the TLD response due to gamma rays. The procedure has relatively high uncertainty because the neutron response of CaF2(Mn) TLDs may vary depending on the source of the material, and this procedure is a generic calculation applicable to CaF2(Mn) TLDs independent of their manufacturer/source. The neutron response given in this practice is a summary of CaF2(Mn) TLD responses reported in the literature. The associated uncertainty envelops the range of results reported and includes the variety of CaF2(Mn) TLDs used as well as the uncertainties in the determination of the neutron response as reported by various authors.4.4 Should the user find the resulting uncertainties too large for his purposes, the neutron response of the CaF2(Mn) TLDs in use during the irradiations must be determined. This practice does not supply guidance on how to determine the neutron response of a specific batch of TLDs.4.5 Neutron effects on electronics under test are usually reported in terms of 1-MeV(Si) equivalent fluence (Practice E722). Neutron effects of TLDs, as discussed here, are reported in units of absorbed dose, since they are corrections to the gamma-ray dose.1.1 This practice describes a procedure for correcting a CaF2(Mn) thermoluminescence dosimeter (TLD) reading for its response to neutrons during the irradiation. The neutron response may be subtracted from the total TLD response to give the gamma-ray response. In fields with a large neutron contribution to the total response, this procedure may result in large uncertainties.1.2 More precise experimental techniques may be applied if the uncertainty derived from this practice is larger than the level that the user can accept. These more precise techniques are not discussed here. The references in Section 8 describe some of these techniques.1.3 This practice does not discuss effects on the TLD reading from neutron interactions with the material surrounding the TLD and used to ensure a charged particle equilibrium. These effects will depend on the isotopic composition of the surrounding material and its thickness, and on the incident neutron spectrum (1).21.4 The values stated in SI units are to be regarded as standard.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2450-23
标准名称:
Standard Practice for Application of CaF2(Mn) Thermoluminescence Dosimeters in Mixed Neutron-Photon Environments
英文名称:
Standard Practice for Application of CaF2(Mn) Thermoluminescence Dosimeters in Mixed Neutron-Photon Environments标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM E2449-05(2013) Standard Guide for Irradiation of Pre-packaged Processed Meat and Poultry Products to Control Pathogens and Other Microorganisms (Withdrawn 2016)
- 下一篇: ASTM E2451-21 Standard Practice for Preserving Ignitable Liquids and Ignitable Liquid Residue Extracts from Fire Debris Samples
- 推荐标准
- ASTM F1252-21 Standard Test Method for Measuring Optical Reflectivity of Transparent Materials
- ASTM F1256-22 Standard Guide for Selection and Practice of Emergency Medical Services Instructor for Emergency Medical Technician (EMT) Training Programs
- ASTM F1264-16e1 Standard Specification and Test Methods for Intramedullary Fixation Devices
- ASTM F1268-90(2020) Standard Guide for Establishing and Operating a Public Information, Education, and Relations Program for Emergency Medical Service Systems
- ASTM F1275-14(2020) Standard Test Method for Performance of Griddles
- ASTM F1276-23 Standard Test Method for Creep Relaxation of Laminated Composite Gasket Materials
- ASTM F1278-96(2021)e1 Standard Guide for Use and Handling of Flexible Retort Food Pouches in the Processing Environment
- ASTM F1279-19 Standard Guide for Ecological Considerations for the Restriction of the Use of Surface Washing Agents: Permeable Land Surfaces
- ASTM F1280-19 Standard Guide for Ecological Considerations for the Use of Surface Washing Agents: Impermeable Surfaces
- ASTM F1284-24 Standard Test Method for Evaluating Carpet Embedded Dirt Removal Effectiveness of Residential Central Vacuum Cleaning Systems
- ASTM F1292-22 Standard Specification for Impact Attenuation of Surfacing Materials Within the Use Zone of Playground Equipment
- ASTM F1301-18(2024)e1 Standard Practice for Labeling Chemical Protective Clothing
- ASTM F1303-04(2021) Standard Specification for Sheet Vinyl Floor Covering with Backing
- ASTM F1306-21 Standard Test Method for Slow Rate Penetration Resistance of Flexible Barrier Films and Laminates
- ASTM F1308-98(2023) Standard Test Method for Quantitating Volatile Extractables in Microwave Susceptors Used for Food Products