4.1 This guide provides a method to determine the thermal performance of low-density blanket-type insulation. It may be used for the purposes of quality assurance, certification, or research.4.2 The thermal resistance of low-density insulation depends significantly on the density, the thickness, and thermal conductivity. Typical low-density, mineral-fiber insulation for buildings may vary in density from one specimen to the next.4.3 Thermal tests are time-consuming in comparison with density and thickness measurements. Low-density insulation material is produced in large quantities. A typical lot would be a truckload or the amount necessary to insulate a house.4.4 The relatively low unit cost of this product and the relatively high cost of thermal resistance testing makes it cost-effective to test only a small percentage of the product area. It is recommended that there be a determination of the density that is representative of a lot by the measurement of the average density of a statistically representative sampling.4.5 A fewer number of thermal measurements are then made to determine the apparent thermal conductivity at the previously determined representative density. The essential significance of this guide is that a large lot of variable material is best characterized by: (a) determining the representative density, and by (b) determining the thermal property at this representative density with a small number of thermal measurements.4.6 Building insulation products are commonly manufactured in thicknesses ranging from 19 to 330 mm (0.75 to 13 in.) inclusive. Experimental work has verified that there is a dependence of λapp on thickness for some low density materials.4.7 The upper limit of test thickness for specimens evaluated using Test Methods C177, C518, and C1114 is established based upon the apparatus design, overall dimensions, expected thermal resistivity level and desired target accuracy. The testing organization is responsible for applying these restrictions when evaluating a product to ensure that the results meet applicable product labels and any existing regulatory requirements (2).4.8 Extrapolation of the apparent thermal conductivity or the thermal resistance beyond the ranges of thickness or density of products tested is not valid.1.1 This guide describes the calculation and interpolation of a thermal resistance value for low-density blanket-type insulation material at a particular density and thickness having been selected as representative of the product. It requires measured values of this average density and thickness, as well as apparent thermal conductivity values determined by either Test Method C177, C518, or C1114.1.2 This guide applies to a density range for mineral-fiber material of roughly 6.4 to 48 kg/m3 (0.4 to 3.0 lb/ft3). It is primarily intended to apply to low-density, mineral-fiber mass insulation batts and blankets, exclusive of any membrane facings. Apparent thermal conductivity data for these products are commonly reported at a mean temperature of 23.9°C (75°F) and a hot-to-cold plate temperature difference of 27.8°C (50°F) or 22.2°C (40°F).1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM C653-17
标准名称:
Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation
英文名称:
Standard Guide for Determination of the Thermal Resistance of Low-Density Blanket-Type Mineral Fiber Insulation标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM B1-13(2018) Standard Specification for Hard-Drawn Copper Wire
- ASTM B100-20 Standard Specification for Wrought Copper-Alloy Bearing and Expansion Plates and Sheets for Bridge and Other Structural Use
- ASTM B1002-16(2020) Standard Specification for Refined Indium
- ASTM B1003-16(2023) Standard Specification for Seamless Copper Tube for Linesets
- ASTM B1004-16(2022) Standard Practice for Contact Performance Classification of Electrical Connection Systems
- ASTM B1005-17(2023) Standard Specification for Copper-Clad Aluminum Bar for Electrical Purposes (Bus Bar)
- ASTM B1008-18 Standard Test Method for Stress-Strain Testing for Overhead Electrical Conductors
- ASTM B1010/B1010M-19 Standard Specification for Copper-Clad Steel Electrical Conductor for Tracer Wire Applications
- ASTM B1011/B1011M-22 Standard Specification for Cobalt Alloy Spring Wire
- ASTM B1013-22 Standard Specification for High Fluidity (HF) Zinc-Aluminum Alloy Thin Wall Die Castings
- ASTM B1014-20 Standard Specification for Welded Copper and Copper Alloy Condenser and Heat Exchanger Tubes with a Textured Surface(s)
- ASTM B1019-21 Standard Test Method for Determination of Surface Oxides on Copper Rod(for Electrical Purposes)
- ASTM B1020/B1020M-22 Standard Specification for Seamless Nickel Alloy Mechanical Tubing and Hollow Bar
- ASTM B1021-21 Standard Test Method for Peel Resistance of Metal Sheets Joined by High Strength Bonds
- ASTM B1022-22 Standard Specification for Zinc-Aluminum-Magnesium Alloys in Ingot Form for Coating Steel Sheet by the Hot-Dip Process