
【国外标准】 Standard Practice for Controlling and Characterizing Errors in Weighing Collected Aerosols
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 The weighing of collected aerosol is one of the most common and purportedly simple analytical procedures in both occupational and environmental atmospheric monitoring (for example, Test Method D4532 or D4096). Problems with measurement accuracy occur when the amount of material collected is small, owing both to balance inaccuracy and variation in the weight of that part of the sampling medium that is weighed along with the sample. The procedures presented here for controlling and documenting such analytical errors will help provide the accuracy required for making well-founded decisions in identifying, characterizing, and controlling hazardous conditions.4.2 Recommendations are given as to materials to be used. Means of controlling or correcting errors arising from instability are provided. Recommendations as to the weighing procedure are given. Finally, a method evaluation procedure for estimating weighing errors is described.4.3 Recommendations are also provided for the reporting of weights relative to LOD (see 3.2.6) and LOQ (see 3.2.7). The quantities, LOD and LOQ, are computed as a result of the method evaluation.1.1 Assessment of airborne aerosol hazards in the occupational setting entails sampling onto a collection medium followed by analysis of the collected material. The result is generally an estimated concentration of a possibly hazardous material in the air. The uncertainty in such estimates depends on several factors, one of which relates to the specific type of analysis employed. The most commonly applied method for analysis of aerosols is the weighing of the sampled material. Gravimetric analysis, though apparently simple, is subject to errors from instability in the mass of the sampling medium and other elements that must be weighed. An example is provided by aerosol samplers designed to collect particles so as to agree with the inhalable aerosol sampling convention (see ISO 7708, Guide D6062, and EN 481). For some sampler types, filter and cassette are weighed together to make estimates. Therefore, if the cassette, for example, absorbs or loses water between the weighings required for a concentration estimation, then errors may arise. This practice covers such potential errors and provides solutions for their minimization.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D6552-06(2021)
标准名称:
Standard Practice for Controlling and Characterizing Errors in Weighing Collected Aerosols
英文名称:
Standard Practice for Controlling and Characterizing Errors in Weighing Collected Aerosols标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E2356-18 Standard Practice for Comprehensive Building Asbestos Surveys
- ASTM E2358-17 Standard Specification for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades
- ASTM E236-66(2022) Standard Specification for Apparatus for Microdetermination of Alkoxyl Groups
- ASTM E2361-13(2021) Standard Guide for Testing Leave-On Products Using In-Situ Methods
- ASTM E2362-22 Standard Practice for Evaluation of Pre-saturated or Impregnated Towelettes for Hard Surface Disinfection
- ASTM E2363-23 Standard Terminology Relating to Manufacturing of Pharmaceutical and Biopharmaceutical Products in the Pharmaceutical and Biopharmaceutical Industry
- ASTM E2365-21 Standard Guide for Environmental Compliance Performance Assessment
- ASTM E237-02(2024) Standard Specification for Laboratory Glass Microvolumetric Vessels (Volumetric Flasks and Centrifuge Tubes)
- ASTM E2373/E2373M-19 Standard Practice for Use of the Ultrasonic Time of Flight Diffraction (TOFD) Technique
- ASTM E2374-16(2021) Standard Guide for Acoustic Emission System Performance Verification
- ASTM E2375-22 Standard Practice for Ultrasonic Testing of Wrought Products
- ASTM E2380/E2380M-15(2019) Standard Test Method for Measuring Pavement Texture Drainage Using an Outflow Meter
- ASTM E2385-11(2016) Standard Guide for Estimating Wildlife Exposure Using Measures of Habitat Quality
- ASTM E2386-04(2017) Standard Guide for Conduct of PDD Screening Examinations
- ASTM E2387-19 Standard Practice for Goniometric Optical Scatter Measurements