
【国外标准】 Standard Guide for Evacuated Reflective Insulation In Cryogenic Service
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This practice covers the use of thermal insulations formed by a number of thermal radiation shields positioned perpendicular to the direction of heat flow. These radiation shields consist of alternate layers of a low-emittance metal and an insulating layer combined such that metal-to-metal contact in the heat flow direction is avoided and direct heat conduction is minimized. These are commonly referred to as multilayer insulations (MLI) or super insulations (SI) by the industry. The performance considerations, typical applications, manufacturing methods, material specification, and safety considerations in the use of these insulations in cryogenic service are also discussed. MLI can be manufactured by any of the following: spiral-wrap method, blanket method, single layer method, and filament-wound method.1.1 This guide covers the use of thermal insulations formed by a number of thermal radiation shields positioned perpendicular to the direction of heat flow. These radiation shields consist of alternate layers of a low-emittance metal and an insulating layer combined such that metal-to-metal contact in the heat flow direction is avoided and direct heat conduction is minimized. These are commonly referred to as multilayer insulations (MLI) or super insulations (SI) by the industry. The technology of evacuated reflective insulation in cryogenic service, or MLI, first came about in the 1950s and 1960s primarily driven by the need to liquefy, store, and transport large quantities of liquid hydrogen and liquid helium. (1-6)21.2 The practice guide covers the use of these MLI systems where the warm boundary temperatures are below approximately 400 K. Cold boundary temperatures typically range from 4 K to 100 K, but any temperature below ambient is applicable.1.3 Insulation systems of this construction are used when heat flux values well below 10 W/m2 are needed for an evacuated design. Heat flux values approaching 0.1 W/m2 are also achievable. For comparison among different systems, as well as for space and weight considerations, the effective thermal conductivity of the system can be calculated for a specific total thickness. Effective thermal conductivities of less than 1 mW/m-K [0.007 Btu·in/h·ft2·°F or R-value 143] are typical and values on the order of 0.01 mW/m-K have been achieved [0.00007 Btu·in/h·ft2·°F or R-value 14 300]. (7) Thermal performance can also be described in terms of the effective emittance of the system, or Εe.1.4 These systems are typically used in a high vacuum environment (evacuated), but soft vacuum or no vacuum environments are also applicable.(8) A welded metal vacuum-jacketed (VJ) enclosure is often used to provide the vacuum environment.1.5 The range of residual gas pressures is from <10-6 torr to 10+3 torr (from <1.33-4 Pa to 133 kPa) with or without different purge gases as required. Corresponding to the applications in cryogenic systems, three sub-ranges of vacuum are also defined: from <10-6 torr to 10-3 torr (from <1.333-4 Pa to 0.133 Pa) [high vacuum/free molecular regime], from 10-2 torr to 10 torr (from 1.33 Pa to 1333 Pa) [soft vacuum, transition regime], from 100 torr to 1000 torr (from 13.3 kPato 133 kPa) [no vacuum, continuum regime].(9)1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific safety hazards, see Section 9.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM C740/C740M-13(2019)
标准名称:
Standard Guide for Evacuated Reflective Insulation In Cryogenic Service
英文名称:
Standard Guide for Evacuated Reflective Insulation In Cryogenic Service标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM B1-13(2018) Standard Specification for Hard-Drawn Copper Wire
- ASTM B100-20 Standard Specification for Wrought Copper-Alloy Bearing and Expansion Plates and Sheets for Bridge and Other Structural Use
- ASTM B1002-16(2020) Standard Specification for Refined Indium
- ASTM B1003-16(2023) Standard Specification for Seamless Copper Tube for Linesets
- ASTM B1004-16(2022) Standard Practice for Contact Performance Classification of Electrical Connection Systems
- ASTM B1005-17(2023) Standard Specification for Copper-Clad Aluminum Bar for Electrical Purposes (Bus Bar)
- ASTM B1008-18 Standard Test Method for Stress-Strain Testing for Overhead Electrical Conductors
- ASTM B1010/B1010M-19 Standard Specification for Copper-Clad Steel Electrical Conductor for Tracer Wire Applications
- ASTM B1011/B1011M-22 Standard Specification for Cobalt Alloy Spring Wire
- ASTM B1013-22 Standard Specification for High Fluidity (HF) Zinc-Aluminum Alloy Thin Wall Die Castings
- ASTM B1014-20 Standard Specification for Welded Copper and Copper Alloy Condenser and Heat Exchanger Tubes with a Textured Surface(s)
- ASTM B1019-21 Standard Test Method for Determination of Surface Oxides on Copper Rod(for Electrical Purposes)
- ASTM B1020/B1020M-22 Standard Specification for Seamless Nickel Alloy Mechanical Tubing and Hollow Bar
- ASTM B1021-21 Standard Test Method for Peel Resistance of Metal Sheets Joined by High Strength Bonds
- ASTM B1022-22 Standard Specification for Zinc-Aluminum-Magnesium Alloys in Ingot Form for Coating Steel Sheet by the Hot-Dip Process