
【国外标准】 Standard Practice for Electromagnetic (Eddy Current) Examination of Seamless and Welded Tubular Products, Titanium, Austenitic Stainless Steel and Similar Alloys
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Eddy current testing is a nondestructive method of locating discontinuities in a product. Changes in electromagnetic response caused by the presence of discontinuities are detected by the sensor, amplified and modified in order to actuate audio or visual indicating devices, or both, or a mechanical marker. Signals can be caused by outer surface, inner surface, or subsurface discontinuities. The eddy current examination is sensitive to many factors that occur as a result of processing (such as variations in conductivity, chemical composition, permeability, and geometry) as well as other factors not related to the tubing. Thus, all received indications are not necessarily indicative of defective tubing.1.1 This practice2 covers procedures for eddy current examination of seamless and welded tubular products made of relatively low conductivity materials such as titanium, stainless steel, and similar alloys, such as nickel alloys. Austenitic chromium-nickel stainless steels, which are generally considered to be nonmagnetic, are specifically covered as distinguished from the martensitic and ferritic straight chromium stainless steels which are magnetic.1.2 This practice is intended as a guide for eddy current examination of both seamless and welded tubular products using either an encircling coil or a probe-coil technique. Coils and probes are available that can be used inside the tubular product; however, their use is not specifically covered in this document. This type of examination is usually employed only to examine tubing which has been installed such as in a heat exchanger.1.3 This practice covers the examination of tubular products ranging in diameter from 0.125 to 5 in. (3.2 to 127.0 mm) and wall thicknesses from 0.005 to 0.250 in. (0.127 to 6.4 mm).1.4 For examination of aluminum alloy tubular products, see standard Practice E215.1.5 Units—The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E426-16(2021)
标准名称:
Standard Practice for Electromagnetic (Eddy Current) Examination of Seamless and Welded Tubular Products, Titanium, Austenitic Stainless Steel and Similar Alloys
英文名称:
Standard Practice for Electromagnetic (Eddy Current) Examination of Seamless and Welded Tubular Products, Titanium, Austenitic Stainless Steel and Similar Alloys标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 2350.16:2006 (R2016)/Amdt 1:2008 Methods of testing portland, blended and masonry cements Determination of air content of masonry cement
- AS/NZS 3350.2.16:1996/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements - Food waste disposers (IEC 60335-2-15:1994, MOD)
- AS/NZS 3580.16:2014 Methods for sampling and analysis of ambient air Determination of polycyclic aromatic hydrocarbons (PAH)
- AS/NZS 3750.16:1998 (R2013) Paints for steel structures Waterborne primer and paint for galvanized, zinc/aluminium alloy-coated and zinc-primed steel
- AS/NZS 3905.16:1998 Quality system guidelines Guidelines to quality in project management
- AS/NZS 4387.16:1996 Domestic kitchen assemblies - Methods of test Determination of calibration of drawer slamming apparatus
- AS/NZS 4524.16:1998 Bonded abrasive products - Dimensions Grinding wheels for cutting-off on an angle grinder
- AS/NZS 61000.4.16:2002/Amdt 1:2012 Electromagnetic compatibility (EMC) Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
- AS/NZS 61558.2.16:2010 (IEC TEXT)/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS 61558.2.16:2010/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS CISPR 16.1.1:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.1:2006 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.2:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances
- AS/NZS CISPR 16.1.3:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Disturbance power
- AS/NZS CISPR 16.1.4:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Radiated disturbances