
【国外标准】 Standard Test Method for Determining In Situ Modulus of Deformation of Rock Using Diametrically Loaded 76-mm (3-in.) Borehole Jack
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Results of this test method are used to predict displacements in rock mass caused by loads from a structure or from underground construction for the load range that the device can apply. It is one of several tests that should be performed.5.2 Because the jack can apply directed loads, this test method can be performed to provide an estimate of anisotropy.5.3 In theory, the analysis of test data is straight forward; the modulus estimate requires a record of applied hydraulic pressure versus borehole diameter change, and a knowledge of the rock's Poisson's ratio. In practice, the above procedure, using the original theoretical formula, frequently has resulted in computing a material modulus that was demonstrably too low.5.4 For analyzing the test data it is assumed that the rock mass is linearly elastic, isotropic, and homogeneous. Within these assumptions, this test method can provide useful data for rock masses for which equivalent continuous properties cannot be found or estimated.NOTE 1: Notwithstanding the statements on precision and bias contained in this test method; the precision of this test method is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing. Users of this test method are cautioned that compliance with Practice D3740 does not in itself assure reliable testing. Reliable testing depends on many factors; Practice D3740 provides a means of evaluating some of those factors.1.1 This test method covers the estimation of in situ modulus of a rock mass at various depths and orientations. Information on time-dependent deformation may also be obtained.1.2 This test method covers testing in an N size drill hole and is more relevant to a borehole jack device designed for “hard rock” than for soft rock.1.3 All observed and calculated values shall conform to the guidelines for significant digits and rounding established in Practice D6026.1.3.1 The method used to specify how data are collected, calculated, or recorded in this standard is not directly related to the accuracy to which the data can be applied in design or other uses, or both. How one applies the results obtained using this standard is beyond its scope.1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are mathematical conversions to inch-pound units that are provided for information only and are not considered standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM D4971-16
标准名称:
Standard Test Method for Determining In Situ Modulus of Deformation of Rock Using Diametrically Loaded 76-mm (3-in.) Borehole Jack
英文名称:
Standard Test Method for Determining In Situ Modulus of Deformation of Rock Using Diametrically Loaded 76-mm (3-in.) Borehole Jack标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 4459.16-2005 Methods of sampling and testing ceramic tiles Determination of small colour differences (ISO 10545-16:1999 MOD)
- AS/NZS 2350.16:2006 (R2016)/Amdt 1:2008 Methods of testing portland, blended and masonry cements Determination of air content of masonry cement
- AS/NZS 3350.2.16:1996/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements - Food waste disposers (IEC 60335-2-15:1994, MOD)
- AS/NZS 3580.16:2014 Methods for sampling and analysis of ambient air Determination of polycyclic aromatic hydrocarbons (PAH)
- AS/NZS 3750.16:1998 (R2013) Paints for steel structures Waterborne primer and paint for galvanized, zinc/aluminium alloy-coated and zinc-primed steel
- AS/NZS 3905.16:1998 Quality system guidelines Guidelines to quality in project management
- AS/NZS 4387.16:1996 Domestic kitchen assemblies - Methods of test Determination of calibration of drawer slamming apparatus
- AS/NZS 4524.16:1998 Bonded abrasive products - Dimensions Grinding wheels for cutting-off on an angle grinder
- AS/NZS 61000.4.16:2002/Amdt 1:2012 Electromagnetic compatibility (EMC) Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
- AS/NZS 61558.2.16:2010 (IEC TEXT)/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS 61558.2.16:2010/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS CISPR 16.1.1:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.1:2006 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.2:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances
- AS/NZS CISPR 16.1.3:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Disturbance power