【国外标准】 Standard Specification for Cold-Formed Electric-Fusion (Arc) Welded High-Strength Low–Alloy Structural Tubing in Shapes, with 50 ksi [345 MPa] Minimum Yield Point
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
1.1 This specification covers three Types and two Grades of cold formed electric-fusion (arc) welded high-strength low-alloy steel tubing of 50 ksi [345 MPa] minimum yield point for use in welded or bolted construction of buildings and for general structural purposes. 1.2 This tubing is produced in square and rectangular sizes with a periphery of 200 in. [500 cm] or less and a specified wall thickness of 1.00 in. [25 mm] or less. Tubes are joined by two longitudinal electric-fusion (arc) welds. Circumferential welds are disallowed. Sizes outside of those listed in Tables 4 and 5 may be ordered provided all other requirements of the specification are met. Typical lengths are 15 to 50 ft [5 to 15 m]. Note 1: Products manufactured to this specification may not be suitable for those applications such as dynamically loaded elements in welded structures, etc. where low-temperature toughness properties may be important. (See Supplementary Requirement S1.) 1.3 This specification covers the following Types: 1.3.1 Type 1—Welded with backing, backing left in the product, 1.3.2 Type 2—Welded with backing, backing removed, 1.3.3 Type 3—Welded without backing. 1.4 Tubing is available in Grades 50 [345] and 50W [345W]. Grade 50 [345] is manufactured from high-strength low-alloy steel. Grade 50W [345W] is manufactured from high-strength low-alloy steel with enhanced atmospheric corrosion resistance. (See 10.1.2) The Grades may not be interchanged without approval of the purchaser. ASTM Specifications for plate that may be applied to Grade 50 [345] and 50W [345W] are listed in Reference Documents and in Table 1. 1.5 This specification is expressed in both inch-pound units and in SI units; however, unless the purchase order or contract specifies the applicable M specification designation (SI units), the inch-pound units shall apply. The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. 1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM A1065/A1065M-18
标准名称:
Standard Specification for Cold-Formed Electric-Fusion (Arc) Welded High-Strength Low–Alloy Structural Tubing in Shapes, with 50 ksi [345 MPa] Minimum Yield Point
英文名称:
Standard Specification for Cold-Formed Electric-Fusion (Arc) Welded High-Strength Low–Alloy Structural Tubing in Shapes, with 50 ksi [345 MPa] Minimum Yield Point标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 1085.18-2003 (R2013) Railway track material Screw spikes and threaded inserts
- AS 1301.P201m-1986 Methods of test for pulp and paper (metric units) Kappa number of pulp
- AS 1301.P414m-1986 Methods of test for pulp and paper (metric units) Conditioning of paper for testing
- AS 1418.18-2001/Amdt 1-2003 Cranes, hoists and winches Crane runways and monorails
- AS 1807.18-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of vibration in workstations and safety cabinets
- AS 1807.18-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of vibration in workstations, safety cabinets and pharmaceutical isolators
- AS 2341.18-1992 Methods of testing bituminous and related roadmaking products Determination of softening point (ring and ball method)
- AS 2362.18-1993 Automatic fire detection and alarm systems - Methods of test for actuating devices Air velocity stability test
- AS 3750.18-2002 (R2013) Paints for steel structures Moisture cure urethane (single-pack) systems
- ASTM D3550/D3550M-17 Standard Practice for Thick Wall, Ring-Lined, Split Barrel, Drive Sampling of Soils
- ASTM D3551-17 Standard Practice for Laboratory Preparation of Soil-Lime Mixtures Using Mechanical Mixer
- ASTM D3552-17 Standard Test Method for Tensile Properties of Fiber Reinforced Metal Matrix Composites
- ASTM D3554-20e1 Standard Specification for Track-Resistant Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 °C Operation
- ASTM D3556-23 Standard Guide for Deposition on Glassware During Mechanical Dishwashing
- ASTM D3557-17 Standard Test Methods for Cadmium in Water