【国外标准】 Standard Test Method for Measuring the Field Performance of Commercial Kitchen Ventilation Systems
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Successful kitchen exhaust hood performance requires the complete capture and containment of the effluent plume along the hood’s entire perimeter. Any effluent leakage moving beyond 3 in. from the hood face will be deemed as having escaped from the hood, even if it may appear to be have been drawn back into the hood. If effluent spills from the hood, hot and greasy kitchens may be the result and the cause of the performance failure needs to be determined and corrected. Oftentimes, the exhaust flow rate needs to be increased to achieve proper hood performance for particular field conditions. As a result, the supply air to the kitchen will need to be increased to maintain the air balance. However, drafty room conditions due to incorrectly placed supply diffusers, cross drafts from windows and doors, return and supply at opposite ends of the kitchen, etc. could also severely degrade hood performance. Incorrectly designed supply systems may not be corrected by increasing the exhaust rate and could be corrected in a much more efficient and economical manner, such as by replacing a 4-way diffuser with a 3-way diffuser directed away from the hood. Likewise, if the plume is strongly captured, the hood may be over-exhausting and reducing the exhaust rate could be considered, along with a corresponding reduction of room supply air to maintain the building’s air balance.5.2 An appropriate airflow balance ensures adequate replacement air for the necessary exhaust conditions and allows the desired air pressure distribution to be maintained.5.3 Negative air pressure in the kitchen with respect to the adjacent indoor spaces ensures that the air flow is from these spaces into the kitchen so that odors and cooking effluent are contained within the kitchen. However, too great a pressure imbalance will severely degrade hood performance by creating a wind tunnel effect. Negative air pressure in the dining area with respect to the outside is usually an indication that the supply air rate is inadequate and as a result the exhaust air system is not performing as specified.1.1 This test method can be used to measure and validate successful design, installation and commissioning of commercial kitchen HVAC and makeup air systems for specific installations.1.2 This test method field evaluates commercial kitchen ventilation system airflows and pressures.1.3 This test method field evaluates visual hood capture and containment performance.1.4 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are for information only.1.5 The data generated is specific to the field conditions as installed.1.6 This test method may involve hazardous materials, gasses (for example, CO) operations, and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F2975-12(2022)
标准名称:
Standard Test Method for Measuring the Field Performance of Commercial Kitchen Ventilation Systems
英文名称:
Standard Test Method for Measuring the Field Performance of Commercial Kitchen Ventilation Systems标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F2947/F2947M-21a Standard Specification for 150 to 1500 mm [6 to 60 in.] Annular Corrugated Profile-Wall Polyethylene (PE) Pipe and Fittings for Sanitary Sewer Applications
- ASTM F2948-21 Standard Guide to Walkway Auditor Qualifications
- ASTM F2949-18 Standard Specification for Pole Vault Box Collars
- ASTM F2950-14(2021) Standard Safety and Performance Specification for Soccer Goals
- ASTM F2951-19 Standard Consumer Safety Specification for Baby Monitors
- ASTM F2952-22 Standard Guide for Determining the Mean Darcy Permeability Coefficient for a Porous Tissue Scaffold
- ASTM F2956-22 Standard Test Methods for Anchor Systems Used for Detention Hollow Metal Systems
- ASTM F2958-14(2019) Standard Guide for Helicopter Inland Search and Rescue (SAR) Technician
- ASTM F2970-22 Standard Practice for Design, Manufacture, Installation, Operation, Maintenance, Inspection and Major Modification of Trampoline Courts
- ASTM F2974-22 Standard Practice for Auditing Amusement Rides and Devices
- ASTM F2975-12(2022) Standard Test Method for Measuring the Field Performance of Commercial Kitchen Ventilation Systems
- ASTM F2977-20 Standard Test Method for Small Punch Testing of Polymeric Biomaterials Used in Surgical Implants
- ASTM F2981-15(2020) Standard Test Method for Verifying Nonporous Flexible Barrier Material Resistance to the Passage of Air
- ASTM F2983-13(2018) Standard Guide for Manufacturers for Labeling and Care Instructions for Wrestling Mats
- ASTM F2986-23 Standard Specification for Corrugated Polyethylene Pipe and Fittings for Mine Leachate, Heap Leach Aeration and Other Mining Applications