
【国外标准】 Standard Practice for Conducting an Interlaboratory Study to Determine Precision Estimates for a Test Method with Fewer Than Six Participating Laboratories
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 ASTM regulations require precision statements in all test methods in terms of repeatability and reproducibility. This practice is used when the number of participating laboratories or materials being tested, or both, in a precision study is less than the number specified by Practice E691. When possible, it is strongly recommended that a full Practice E691 standard protocol be followed to determine test method precision. Precision results produced by the procedures presented in this standard will not have the same degree of accuracy as results generated by a full Practice E691 protocol. This procedure will allow for the development of useful precision results when a full complement of laboratories is not available for interlaboratory testing.5.2 This practice is based on recommendations for interlaboratory studies and data analysis presented in Practice E691. This practice does not concern itself with the development of test methods but with a standard means for gathering information and treating the data needed for developing a precision statement for a test method when a complete Practice E691 interlaboratory study and data analysis are not possible.1.1 This practice describes the techniques for planning, conducting, analyzing, and treating results of an interlaboratory study (ILS) for estimating the precision of a test method when fewer than six laboratories are available to meet the recommended minimum requirements of Practice E691. Data obtained from an interlaboratory study are useful in identifying variables that require modifications for improving test method performance and precision.1.2 Precision estimates developed using this practice will not be statistically equivalent to precision estimates produced by Practice E691 because a small number of laboratories are used. The smaller number of participating laboratories will seriously reduce the value of precision estimates reported by this practice. However, under circumstances where only a limited number of laboratories are available to participate in an ILS, precision estimates developed by this practice will provide the user with useful information concerning precision for a test method.1.3 A minimum of three qualified laboratories is required for conducting an ILS using this practice. If six or more laboratories are available to participate in an ILS for a given test method, Practice E691 shall be used for conducting the ILS.1.4 Since the primary purpose of this practice is the development of the information needed for a precision statement, the experimental design in this practice will not be optimum for evaluating all materials, test methods, or as a tool for individual laboratory analysis.1.5 Because of the reduced number of participating laboratories, a Laboratory Monitor shall be used in the ILS. See Guide E2335.1.6 Field of Application—This practice is concerned with test methods that yield numerical values or a series of numerical values for different properties associated with the test method. The numerical values mentioned above are typically the result of calculations from a set of measurements.1.7 This practice includes design information suitable for use with the development of interlaboratory studies for test methods that have categorization (go-no-go) allocation test results. However, it does not provide a recommended statistical practice for evaluating the go-no-go data.1.8 This practice cannot be used to provide quantitative measures.1.9 This practice is issued under Committee E05, but it is generic in its statistical approach such that it is applicable to any other method.1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.11 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2653-23
标准名称:
Standard Practice for Conducting an Interlaboratory Study to Determine Precision Estimates for a Test Method with Fewer Than Six Participating Laboratories
英文名称:
Standard Practice for Conducting an Interlaboratory Study to Determine Precision Estimates for a Test Method with Fewer Than Six Participating Laboratories标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 推荐标准
- ASTM F1591-95(2019) Standard Practice for Visual Signals Between Persons on the Ground and in Aircraft During Ground Emergencies
- ASTM F1592-12(2019) Standard Test Methods for Detention Hollow Metal Vision Systems
- ASTM F1599-95(2018) Standard Guide for Collecting Performance Data on Temporary Storage Devices
- ASTM F1601-01(2023) Standard Test Method for Motor Life Evaluation of an Electric Motorized Nozzle for Central Vacuum Cleaning Systems
- ASTM F1604-15(2020)e1 Standard Specification for Freezers, Ice Cream, Soft Serve, Shake
- ASTM F1606-19 Standard Practice for Rehabilitation of Existing Sewers and Conduits with Deformed Polyethylene (PE) Liner
- ASTM F1607-95(2018) Standard Guide for Reporting of Test Performance Data for Oil Spill Response Pumps
- ASTM F1608-21 Standard Test Method for Microbial Ranking of Porous Packaging Materials (Exposure Chamber Method)
- ASTM F1616-95(2016) Standard Guide for Scope of Performance of First Responders Who Practice in the Wilderness or Delayed or Prolonged Transport Settings
- ASTM F1637-21 Standard Practice for Safe Walking Surfaces
- ASTM F1645/F1645M-22 Standard Test Method for Water Migration in Honeycomb Core Materials
- ASTM F1646-16 Standard Terminology Relating to Walkway Safety and Footwear
- ASTM F1647-11(2018) Standard Test Methods for Organic Matter Content of Athletic Field Rootzone Mixes
- ASTM F1650-21 Standard Practice for Evaluating Tire Traction Performance Data Under Varying Test Conditions
- ASTM F1653-95(2020) Standard Guide for Scope of Performance of Triage in a Prehospital Environment