
【国外标准】 Standard Test Method for Centrifuge Moisture Equivalent of Soils
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 All water contained in a saturated soil cannot be removed by gravity drainage alone. The amount of water retained after gravity drainage is usually expressed as the water holding capacity or specific retention of the soil. These values may be influenced by elapsed time, the particle-size distribution and the plasticity of the soil. In most cases, as the plasticity increases so does the moisture equivalent value.5.2 The centrifuge moisture equivalent is determined by applying a centrifugal force great enough to reduce the capillary fringe zone sufficiently so that it can be ignored without introducing error. The centrifical force is maintained sufficiently low as not to withdraw a large proportion of the water that is held securely above the capillary fringe (see Note 1).5.3 It has been determined that for at least medium-textured soils (sandy to silty particle-size distribution) the centrifuge moisture equivalent approximates the water holding capacity and when combined with the bulk density can be used to calculate an approximate specific retention and specific yield. These properties when combined with porosity can be used to estimate aquifer storage coefficient.NOTE 1: If a soil will hold water 100 mm by capillarity acting against gravity, the soil will theoretically be able to hold the water only 0.1 mm against a centrifugal force that is 1000 times greater than the force of gravity.NOTE 2: The statements on precision and bias contained in this test method; the precision of this test method is dependent on the competence of the personnel performing it, and the suitability of the equipment and facilities used. Agencies that meet the criteria of Practice D3740 are generally considered capable of competent and objective testing. Users of this test method are cautioned that compliance with Practice D3740 does not in itself assure reliable testing. Reliable testing depends on many factors; Practice D3740 provides a means of evaluating some of these factors.1.1 This test method covers the determination of the moisture equivalent of soil in the laboratory by means of a centrifuge technique.1.2 This test method is limited to specimens of coarse-grained sandy soils having a maximum particle size of less than 2.00 mm and with fines of low plasticity. Soils having a unified soil classification, based upon procedures outlined in Practice D2488 such as SP, SW, SC-SM, or SM are considered acceptable for the test method.1.2.1 For soils that are predominantly fine-grained, coarse-grained soils with medium to high plasticity, intact specimens or soils being tested at a specific density or unit weight refer to Test Methods D6836.1.3 This test method is intended to be performed in a constant temperature environment. Variations in temperature exceeding the range outlined in 8.7 may influence the test data.1.4 Units—The values stated in SI units are to be regarded as the standard except for sieve designations, which also include the “alternative” system in accordance with E11.1.5 All recorded and calculated values shall conform to the guide for significant digits and rounding established in Practice D6026.1.6 The procedures used to specify how data are collected/recorded and calculated in this standard are regarded as the industry standard. In addition, they are representative of the significant digits that generally should be retained. The procedures used do not consider material variation, purpose for obtaining data, special purpose studies, or any considerations for the user’s objectives; and it is common practice to increase or reduce significant digits of reported data to commensurate with these considerations. It is beyond the scope of these test methods to consider significant digits used in analysis methods for engineering design.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM D425-17
标准名称:
Standard Test Method for Centrifuge Moisture Equivalent of Soils
英文名称:
Standard Test Method for Centrifuge Moisture Equivalent of Soils标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 60598.2.17:2006 Luminaires Particular requirements - Luminaires for stage lighting, television, film and photographic studios (outdoor and indoor)(IEC 60598.2.17, Ed. 1.0 (1984) MOD)
- AS/NZS 60745.2.17:2003 Hand-held motor-operated electric tools - Safety - Particular requirements for routers and trimmers
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
- ASTM A1-00(2018) Standard Specification for Carbon Steel Tee Rails
- ASTM A1000/A1000M-17(2023) Standard Specification for Steel Wire, Carbon and Alloy Specialty Spring Quality
- ASTM A1001-18 Standard Specification for High-Strength Steel Castings in Heavy Sections
- ASTM A1002-16(2020) Standard Specification for Castings, Nickel-Aluminum Ordered Alloy
- ASTM A1004/A1004M-99(2018) Standard Practice for Establishing Conformance to the Minimum Expected Corrosion Characteristics of Metallic, Painted-Metallic, and Nonmetallic-Coated Steel Sheet Intended for Use as Cold Formed Framing Members
- ASTM A1009-18 Standard Specification for Soft Magnetic MnZn Ferrite Core Materials for Transformer and Inductor Applications
- ASTM A101-04(2019) Standard Specification for Ferrochromium
- ASTM A1010/A1010M-13(2018) Standard Specification for Higher-Strength Martensitic Stainless Steel Plate, Sheet, and Strip
- ASTM A1012-10(2021) Standard Specification for Seamless and Welded Ferritic, Austenitic and Duplex Alloy Steel Condenser and Heat Exchanger Tubes With Integral Fins
- ASTM A1015-01(2018) Standard Guide for Videoborescoping of Tubular Products for Sanitary Applications
- ASTM A1016/A1016M-23 Standard Specification for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stainless Steel Tubes