- 您的位置:
- 快3网下载安装到手机 >>
- 全部标准分类 >>
- 国外标准 >>
- ASTM >>
- ASTM D6443-14(2019)e1 Standard Test Method for Determination of Calcium, Chlorine, Copper, Magnesium, Phosphorus, Sulfur, and Zinc in Unused Lubricating Oils and Additives by Wavelength Dispersive X-ray Fluorescence Spectrometry (Mathematical Correction Procedure)

【国外标准】 Standard Test Method for Determination of Calcium, Chlorine, Copper, Magnesium, Phosphorus, Sulfur, and Zinc in Unused Lubricating Oils and Additives by Wavelength Dispersive X-ray Fluorescence Spectrometry (Mathematical Correction Procedure)
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Lubricating oils can be formulated with additives, which can act as detergents, anti-oxidants, anti-wear agents, and so forth. Some additives can contain one or more of calcium, copper, magnesium, phosphorus, sulfur, and zinc. This test method can be used to determine if the oils, additives, and additive packages meet specification with respect to content of these elements.4.2 Several additive elements and their compounds are added to the lubricating oils to give beneficial performance (Table 3).4.3 This test method can also be used to determine if lubricating oils, additives, and additive packages meet specification with respect to chlorine concentration. In this context, specification can refer to contamination.4.4 This test method is not intended for use on samples that contain some component that significantly interferes with the analysis of the elements specified in the scope.4.5 This test method can complement other test methods for lube oils and additives, including Test Methods D4628, D4927, D4951, and D5185.1.1 This test method covers the determination of calcium, chlorine, copper, magnesium, phosphorus, sulfur, and zinc in unused lubricating oils, additives, and additive packages by wavelength dispersive X-ray fluorescence spectrometry. Matrix effects are handled with mathematical corrections.1.2 For each element, the upper limit of the concentration range covered by this test method is defined by the highest concentration listed in Table 1. Samples containing higher concentrations can be analyzed following dilution.1.3 For each element, the lower limit of the concentration range covered by this test method can be estimated by the limit of detection (LOD)2 (see also 40 CFR 136 Appendix B) or limit of quantification (LOQ),2 both of which can be estimated from Sr, the repeatability standard deviation. LOD and LOQ values, determined from results obtained in the interlaboratory study on precision, are listed in Table 2.1.3.1 LOD and LOQ are not intrinsic constants of this test method. LOD and LOQ depend upon the precision attainable by a laboratory when using this test method.1.4 This test method uses regression software to determine calibration parameters, which can include influence coefficients (that is, interelement effect coefficients) (Guide E1361), herein referenced as alphas. Alphas can also be determined from theory using relevant software.1.5 Setup of this test method is intended for persons trained in the practice of X-ray spectrometry. Following setup, this test method can be used routinely.1.6 The values stated in either SI units or angstrom (Å) units are to be regarded separately as standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D6443-14(2019)e1
标准名称:
Standard Test Method for Determination of Calcium, Chlorine, Copper, Magnesium, Phosphorus, Sulfur, and Zinc in Unused Lubricating Oils and Additives by Wavelength Dispersive X-ray Fluorescence Spectrometry (Mathematical Correction Procedure)
英文名称:
Standard Test Method for Determination of Calcium, Chlorine, Copper, Magnesium, Phosphorus, Sulfur, and Zinc in Unused Lubricating Oils and Additives by Wavelength Dispersive X-ray Fluorescence Spectrometry (Mathematical Correction Procedure)标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM E2356-18 Standard Practice for Comprehensive Building Asbestos Surveys
- ASTM E2358-17 Standard Specification for Performance of Glazing in Permanent Railing Systems, Guards, and Balustrades
- ASTM E236-66(2022) Standard Specification for Apparatus for Microdetermination of Alkoxyl Groups
- ASTM E2361-13(2021) Standard Guide for Testing Leave-On Products Using In-Situ Methods
- ASTM E2362-22 Standard Practice for Evaluation of Pre-saturated or Impregnated Towelettes for Hard Surface Disinfection
- ASTM E2363-23 Standard Terminology Relating to Manufacturing of Pharmaceutical and Biopharmaceutical Products in the Pharmaceutical and Biopharmaceutical Industry
- ASTM E2365-21 Standard Guide for Environmental Compliance Performance Assessment
- ASTM E237-02(2024) Standard Specification for Laboratory Glass Microvolumetric Vessels (Volumetric Flasks and Centrifuge Tubes)
- ASTM E2373/E2373M-19 Standard Practice for Use of the Ultrasonic Time of Flight Diffraction (TOFD) Technique
- ASTM E2374-16(2021) Standard Guide for Acoustic Emission System Performance Verification
- ASTM E2375-22 Standard Practice for Ultrasonic Testing of Wrought Products
- ASTM E2380/E2380M-15(2019) Standard Test Method for Measuring Pavement Texture Drainage Using an Outflow Meter
- ASTM E2385-11(2016) Standard Guide for Estimating Wildlife Exposure Using Measures of Habitat Quality
- ASTM E2386-04(2017) Standard Guide for Conduct of PDD Screening Examinations
- ASTM E2387-19 Standard Practice for Goniometric Optical Scatter Measurements