
【国外标准】 Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Flash point measures the response of the test specimen to heat and ignition source under controlled laboratory conditions. It is only one of a number of properties that must be considered in assessing the overall flammability hazard of a material.5.2 Flash point is used in shipping and safety regulations by governmental regulatory agencies to define flammable and combustible materials and to classify them. Consult the particular regulation involved for precise definitions of these classes.5.3 Flash point can indicate the possible presence of highly volatile and flammable impurities or contaminants in a given liquid, such as the presence of residual solvents in solvent-refined drying oils.5.4 These equilibrium flash point test methods use a smaller specimen (2 mL) and a shorter test time (1 min) than traditional non-equilibrium test methods such as Test Method D56 and Test Methods D93.5.5 Test Methods D3828, Test Method D8174, and ISO 3679 are similar test methods and use the same apparatus.1.1 These test methods cover procedures for determining whether a material does or does not flash at a specified temperature (flash/no flash Method A) or for determining the lowest finite temperature at which a material does flash (Method B), when using a small scale closed-cup apparatus. The test methods are applicable to paints, enamels, lacquers, varnishes, solvents, and related products having a flash point between 0 °C and 110 °C (32 °F and 230 °F) and viscosity lower than 15 000 mm2/s (cSt) at 25 °C (77 °F).NOTE 1: Tests at higher or lower temperatures are possible however the precision has not been determined.NOTE 2: More viscous materials can be tested in accordance with Annex A4.NOTE 3: Organic peroxides can be tested in accordance with Annex A5, which describes the applicable safety precautions.NOTE 4: The U.S. Department of Labor (OSHA, Hazard Communications), the U.S. Department of Transportation (RSPA), and the U.S. Environmental Protection Agency (EPA) have specified Test Methods D3278 as one of several acceptable methods for the determination of flash point of liquids in their regulations.1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.3 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D3278-21
标准名称:
Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus
英文名称:
Standard Test Methods for Flash Point of Liquids by Small Scale Closed-Cup Apparatus标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F1697-18 Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-Wound Liner Pipe Rehabilitation of Existing Sewers and Conduit
- ASTM F1698-21 Standard Practice for Installation of Poly(Vinyl Chloride)(PVC) Profile Strip Liner and Cementitious Grout for Rehabilitation of Existing Man-Entry Sewers and Conduits
- ASTM F17-20 Standard Terminology Relating to Primary Barrier Packaging
- ASTM F1701-12(2018) Standard Specification for Unused Rope with Special Electrical Properties
- ASTM F1702-10(2018) Standard Test Method for Measuring Impact-Attenuation Characteristics of Natural Playing Surface Systems Using a Lightweight Portable Apparatus
- ASTM F1704-12(2022) Standard Test Method for Capture and Containment Performance of Commercial Kitchen Exhaust Ventilation Systems
- ASTM F1705-96(2020) Standard Guide for Training Emergency Medical Services Ambulance Operations
- ASTM F1713-08(2021)e1 Standard Specification for Wrought Titanium-13Niobium-13Zirconium Alloy for Surgical Implant Applications (UNS R58130)
- ASTM F1714-96(2018) Standard Guide for Gravimetric Wear Assessment of Prosthetic Hip Designs in Simulator Devices
- ASTM F1716-96(2022) Standard Guide for Transition and Performance of Marine Software Systems Maintenance
- ASTM F1717-21 Standard Test Methods for Spinal Implant Constructs in a Vertebrectomy Model
- ASTM F1728-96(2020) Standard Practice for Multiple Persons Cold Water Survival/Rescue Technique: Huddle Position
- ASTM F1732-12(2018) Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer and Drain Pipe Containing Recycled PVC Material
- ASTM F1733-24 Standard Specification for Butt Heat Fusion Polyamide(PA) Plastic Fitting for Polyamide(PA) Plastic Pipe and Tubing
- ASTM F1734-19 Standard Practice for Qualification of a Combination of Squeeze Tool, Pipe, and Squeeze-Off Procedures to Avoid Long-Term Damage in Polyethylene (PE) Gas Pipe