
【国外标准】 Standard Guide for Measuring Power Frequency Magnetic Properties of Flat-Rolled Electrical Steels Using Small Single Sheet Testers
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Materials Evaluation—Small single sheet testers were developed to supplement the testing of Epstein specimens for various applications. They are especially appropriate for determining the magnetic properties of samples when insufficient material is available for preparation of an Epstein specimen. Although the small specimen size is attractive, the precision of the small sheet testers is not expected to be as good as that of the test method Test Method A343/A343M. Small sheet testers are frequently used to measure the properties of both fully processed and semiprocessed nonoriented and magnetic lamination steels. Specimens of semiprocessed steels are normally subjected to an appropriate quality development anneal prior to testing. Small sheet testers may also be used to evaluate oriented electrical steels in either the as sheared or stress-relief annealed condition.1.1 This guide covers procedures for interpreting the specific core loss and peak permeability determined using small single-sheet test systems. It is limited to single-sheet test systems that require a test specimen or coupon be cut from the material being tested and are designed such that the entire width of that test specimen is magnetized during testing.1.2 This guide is primarily intended for measurements of the magnetic properties of flat-rolled electrical steels at frequencies of 50 Hz or 60 Hz under sinusoidal flux conditions.1.3 This guide includes procedures to provide correlation with the 25-cm Epstein test method (Test Method A343/A343M).1.4 The range of magnetic flux densities is governed by the properties of the test specimens and the instruments and test power source. Nonoriented electrical steels may be tested at magnetic flux densities up to about 16-kG [1.6T] for core loss. The maximum magnetic field strength for peak permeability testing is limited by the current carrying capacity of the magnetizing winding and the test power source. Single sheet testers are typically capable of testing at magnetic field strengths up to 50 Oe [4000 A/m] or more.1.5 Within this guide, a small single sheet tester (small SST) is defined as a magnetic tester designed to test flat, rectangular sheet-type specimens. Typical specimens for these testers are square (or nearly so). The design of the small SST test fixture may be small enough to accommodate specimens about 5 by 5 cm or may be large enough to accommodate specimens about 36 by 36 cm. Specimens for a particular SST must be appropriate for the particular test fixture.1.6 This guide covers two alternative test methods: Method 1 and Method 2.1.6.1 Method 1 is an extension of Method 1 of Test Method A804/A804M, which describes a test fixture having two windings that encircle the test specimen and two low-reluctance, low-core loss ferromagnetic yokes that serve as flux return paths. The dimensions of the test fixture for Method 1 are not fixed but rather may be designed and built for any nominal specimen dimension within the limits given in 1.5. The power loss in this case is determined by measuring the average value of the product of primary current and induced secondary voltage.1.6.2 Method 2 covers the use of a small single sheet tester, which employs a magnetizing winding, a magnetic flux sensing winding, and a magnetic field strength detector. The power loss in this case is determined by measuring the average value of the product of induced secondary voltage and magnetic field strength.1.6.3 The calibration method described in the annex of this guide applies to both test methods.1.7 The values and equations stated in customary (cgs-emu and inch-pound) or SI units are to be regarded separately as standard. Within this standard, SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with this standard.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM A1036-04(2020)
标准名称:
Standard Guide for Measuring Power Frequency Magnetic Properties of Flat-Rolled Electrical Steels Using Small Single Sheet Testers
英文名称:
Standard Guide for Measuring Power Frequency Magnetic Properties of Flat-Rolled Electrical Steels Using Small Single Sheet Testers标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI X9.100-160-2-2020 Magnetic Ink Printing (MICR) - Part 2 EPC Field Use
- ANSI X9.112-2-2020 Wireless Management and Published Security - Part 2: POS and ATM
- ANSI X9.117-2020 Financial Services - Mutual Authentication for Secure Remote Access
- ANSI X9.134-1-2020 Core Banking: Mobile Financial Services - General Framework
- ANSI X9.138-2020 Distributed Ledger Technologies (DLT) Terminology
- ANSI X9.99-2009 (R2020) Financial Services-Privacy Impact Assessment
- ASTM D3550/D3550M-17 Standard Practice for Thick Wall, Ring-Lined, Split Barrel, Drive Sampling of Soils
- ASTM D3551-17 Standard Practice for Laboratory Preparation of Soil-Lime Mixtures Using Mechanical Mixer
- ASTM D3552-17 Standard Test Method for Tensile Properties of Fiber Reinforced Metal Matrix Composites
- ASTM D3554-20e1 Standard Specification for Track-Resistant Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 °C Operation
- ASTM D3556-23 Standard Guide for Deposition on Glassware During Mechanical Dishwashing
- ASTM D3557-17 Standard Test Methods for Cadmium in Water
- ASTM D3561-16(2021)e1 Standard Test Method for Lithium, Potassium, and Sodium Ions in Brackish Water, Seawater, and Brines by Atomic Absorption Spectrophotometry
- ASTM D3562-22 Standard Performance Specification for Woven Drycleanable Coat Fabrics
- ASTM D3564-22 Standard Practice for Application of Floor Polishes to Maintain Vinyl Composition Tile or Flooring