
【国外标准】 Standard Test Method for Evaluating Response Robot Sensing: Visual Acuity
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Various levels of visual acuity are essential when remotely operating robots in unstructured and often hazardous environments. Missions typically include establishing situational awareness, finding available paths, maneuvering through obstacles, identifying objects of interest, and performing detailed inspections. This test method measures robot system far-field and near-field visual acuity which are applicable to virtually every mission. These quantitative measures of performance provide a common language that allows robot users to better understand and express their own requirements and improve the way visual sensing capabilities are specified.5.2 Multiple cameras could be incorporated into remotely operated robotic systems since a single camera is unlikely to be effective for all aspects of a mission. For example, cameras with zoom lenses are often used for far-field tasks. Cameras with close focus capabilities are often used for near-field tasks. Wide-angle lenses are often used for driving and obstacle avoidance. This test method characterizes each onboard camera to understand overall system capabilities.5.3 This test method provides a way to unambiguously specify robot requirements in terms of the related measures of visual acuity and field of view. This helps quantify the trade-offs and general usefulness of optical versus digital zoom cameras and fixed versus variable focus lenses. The visual acuity charts can also help provide quantitative measures of performance within other test methods and training scenarios. See Figs. 2-4 for illustrations.FIG. 2 This Baseline Image is Used for Purposes of Comparisons BelowFIG. 3 Three Images of the Same Scene with the Same Image Resolution. Top Row Shows Field of View Increasing from Left to Right (the image “zooms out”) While Bottom Row Shows Acuity Decreasing (features of the same size become harder to clearly observe)FIG. 4 Three Images of the Same Scene with the Same Field of View. The Top Row Shows the Field of View is Unchanged While Bottom Row Shows Both Resolution and Acuity Increasing (features become clearer)5.4 This test method helps evaluate the effect of illumination on visual acuity. In dark environments, robots typically need to illuminate the scene to be effective. Far-field objects downrange require much greater light intensity than near-field objects close to the robot. Variable illumination helps ensure the scene is neither too dark nor overwhelmingly lighted so as to thwart the camera’s ability to discern visual details (so-called “washout” of the image). Variable illumination is especially important when quickly transitioning from far-field to near-field and back again.5.5 Key features of response robots are that they are remotely operated from safe standoff distances, deployable at operational tempos, capable of operating in complex environments, sufficiently hardened against harsh environments, reliable and field serviceable, durable or cost-effectively disposable, and equipped with operational safeguards. As such, a major advantage of using robots in response operations is to enhance the safety and effectiveness of responders or soldiers.5.6 This test method aligns user expectations with actual capabilities to understand the inherent trade-offs in deployable systems at any given cost. For example, an increase in image resolution typically results in improved field of view or acuity, but not necessarily both. An increase in both may not be possible for robots of a desired weight, endurance, or cost. Appropriate levels of understanding can help ensure that requirement specifications are articulated within the limit of current capabilities.5.7 This test method provides a tangible representation of essential robot capabilities with quantifiable measures of performance. When considered with other related test methods in the suite, it facilitates communication among communities of robot users and manufacturers. As such, this test method can be used to:5.7.1 Inspire technical innovation and guide manufacturers toward implementing combinations of capabilities necessary to perform essential mission tasks.5.7.2 Measure and compare essential robot capabilities. This test method can establish the reliability of the system to perform specified tasks, highlight break-through capabilities, and encourage hardening of developmental systems.5.7.3 Inform purchasing decisions, conduct acceptance testing, and align deployment objectives with statistically significant robot capabilities data captured through repeated testing and comparison of quantitative results.5.7.4 Focus operator training and measure proficiency as a repeatable practice task that exercises actuators, sensors, and operator interfaces. The test method can be embedded into training scenarios to capture and compare quantitative scores even within uncontrolled environmental variables. This can help develop, maintain, measure, and track very perishable skills over time and enable comparisons across squads, regions, or national averages.5.8 Although this test method was developed as part of a suite of sensing tests for response robots, it may be applicable to other domains. Different user communities can set their own thresholds of acceptable performance within the test method for various mission requirements.5.9 It is recommended that users of this test method consider their particular robot requirements when interpreting the test results. The capability evaluated in this test method alone shall be interpreted according to the scope of this test method and shall not be considered as an overall indication of the capability of the robot’s mobility subsystem nor of the entire robotic system. A single test method only captures the specified single aspect of a robot’s capabilities. A more complete characterization of a robot’s capabilities requires test results from a wider set of test methods.1.1 The purpose of this test method is to specify the apparatuses, procedures, and performance metrics necessary to quantitatively measure a robot’s visual acuity as displayed to a remote operator or vision algorithm. The primary performance metric for this test method shall be a robot’s possession of such a capability with a specified statistical significance level.1.2 Secondary performance metrics are the robot’s field of view and aspect ratio.1.3 This test method can also be used to measure the operator proficiency in performing the specified task. The corresponding performance metric may be the number of completed task repetitions per minute over an assigned time period ranging from 10 to 30 minutes.1.4 This test method is a part of the sensing suite of response robot test methods, but this test method is stand-alone and complete. This test method applies to systems operated remotely from a standoff distance appropriate for the intended mission. The system includes a remote operator in control of all functionality and any assistive features or autonomous behaviors that improve the effectiveness or efficiency of the overall system.1.5 The apparatus, specified in Section 6, can only test a limited range of a robot’s capabilities. When the robot has been tested through the limit or limits of the apparatus, a note shall be associated with the results indicating that the robot’s actual capability may be outside of the limit or limits imposed by the test apparatus. For example, the robot could exceed the capabilities of the printing process used to create the charts used in the apparatus.1.6 Performing Location—This test method may be performed anywhere the specified apparatuses and environmental conditions can be implemented.1.7 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard. Both units are referenced to facilitate acquisition of materials internationally and minimize fabrication costs.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2566-17a
标准名称:
Standard Test Method for Evaluating Response Robot Sensing: Visual Acuity
英文名称:
Standard Test Method for Evaluating Response Robot Sensing: Visual Acuity标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 2566-1982 Plastics pipelaying design
- ASTM F2783-20 Standard Practice for Design, Manufacture, Operation, Maintenance, and Inspection of Amusement Rides and Devices, in Canada
- ASTM F2787-13(2018) Standard Practice for Structural Design of Thermoplastic Corrugated Wall Stormwater Collection Chambers
- ASTM F2789-10(2020) Standard Guide for Mechanical and Functional Characterization of Nucleus Devices
- ASTM F2790-10(2019)e1 Standard Practice for Static and Dynamic Characterization of Motion Preserving Lumbar Total Facet Prostheses
- ASTM F2791-24 Standard Guide for Assessment of Surface Texture of Non-Porous Biomaterials in Two Dimensions
- ASTM F2793-14(2023) Standard Specification for Bicycle Grips
- ASTM F2795-18 Standard Test Method for Performance of Self-Contained Soft Serve and Shake Freezers
- ASTM F2797-19 Standard Test Method for Evaluating Edge Cleaning Effectiveness of Vacuum Cleaners
- ASTM F2798-09(2023) Standard Specification for Sealless Lube Oil Pump with Oil Through Motor for Marine Applications
- ASTM F2799-14(2019) Standard Practice for Maintenance of Aircraft Electrical Wiring Systems
- ASTM F2810-15(2020) Standard Specification for Elliptical Trainers
- ASTM F2817-13(2023) Standard Specification for Poly (Vinyl Chloride) (PVC) Gas Pressure Pipe and Fittings For Maintenance or Repair
- ASTM F2818-10(2023) Standard Specification for Specification for Crosslinked Polyethylene (PEX) Material Gas Pressure Pipe and Tubing
- ASTM F2821-15(2020) Standard Test Methods for Basket Type Rescue Litters