
【国外标准】 Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
3.1 An accelerated test for determining the resistance of interior coatings to mold growth is useful in estimating the performance of coatings designed for use in interior environments that promote mold growth and in evaluating compounds that may inhibit such growth and the aggregate levels for their use (see also Note 1).3.2 This test method should preferably be used by persons who have had basic microbiological training.1.1 This test method describes the use of an environmental chamber and operating conditions to evaluate the relative resistance of interior coatings to surface fungal growth in a severe interior environment during a 4-week period.1.2 This test method can be used to evaluate the comparative resistance of interior coatings to accelerated mold growth. Performance at a certain rating does not imply any specific period of time for a fungal free coating. However, a better rated coating nearly always performs better in actual end use.NOTE 1: This test method is intended for the accelerated evaluation of an interior coatings’ resistance to fungal defacement. Use of this test method for evaluating exterior coatings’ performance has not been validated, nor have the limitations for such use been determined. If this test method is to be used for the testing of an exterior coating system, a precautionary statement regarding interpretation of results as being outside of the scope of this test method must be included in the test report. Any accelerated weathering (leaching, weathering machine exposure, etc.) should be reported and should also bear reference to the fact that it is beyond the current scope of this test method.1.3 Temperature and humidity must be effectively controlled within the relatively narrow limits specified in order for the chamber to function reproducibly during the short test period. Severity and rate of mold growth on a film is a function of the moisture content of both the film and the substrate. A relative humidity of >93 % at a temperature of 32.5 ± 1 °C (90 ± 2 °F ) is necessary to initiate and maintain mold growth and for test panels to develop rapidly and maintain an adequate moisture level to support mold growth.1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D3273-21
标准名称:
Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber
英文名称:
Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM D3272-76(2003) Standard Practice for Vacuum Distillation of Solvents From Solvent-Reducible Paints For Analysis (Withdrawn 2008)
- 下一篇: ASTM D3274-09(2021) Standard Test Method for Evaluating Degree of Surface Disfigurement of Paint Films by Fungal or Algal Growth, or Soil and Dirt Accumulation
- 推荐标准
- AS 1038.21.1.2-2002 (R2013) Coal and coke - Analysis and testing Higher rank coal and coke - Relative density - Analysis sample/volumetric method
- AS 1038.21.2-1992 Coal and coke - Analysis and testing Higher rank coal and coke - Relative density - Lump sample
- AS 1807.21-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of inward air velocity of Class I biological safety cabinets
- AS 2005.21.1-1990 Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Standardized fuse systems - Fuses with fuse-links with blade contacts
- AS 2005.21.2-1990 Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Standardized fuse systems - Fuses with fuse-links for bolted connections
- ASTM D4127-18a Standard Terminology Used with Ion-Selective Electrodes
- ASTM D4129-05(2020) Standard Test Method for Total and Organic Carbon in Water by High Temperature Oxidation and by Coulometric Detection
- ASTM D4131-19 Standard Practice for Sampling Fish with Rotenone
- ASTM D4138-07a(2022) Standard Practices for Measurement of Dry Film Thickness of Protective Coating Systems by Destructive, Cross-Sectioning Means
- ASTM D4139-04(2020) Standard Guide for Determining Volatile and Nonvolatile Content of Pigments
- ASTM D4140-07(2018) Standard Guide for Determining Volatile and Nonvolatile Content of Driers, Drying Oils, Naval Stores, and Solvents
- ASTM D4141/D4141M-22 Standard Practice for Conducting Black Box and Solar Concentrating Exposures of Coatings
- ASTM D4142-89(2022) Standard Guide for Testing Epoxy Resins
- ASTM D4155-22 Standard Performance Specification for Women's and Girls' Woven Sportswear, Shorts, Slacks, and Suiting Fabrics
- ASTM D4157-13(2022) Standard Test Method for Abrasion Resistance of Textile Fabrics (Oscillatory Cylinder Method)