
【国外标准】 Standard Test Method for Retroreflectance of Horizontal Coatings
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The quantity coefficient of retroreflected luminance is a measure of the reflected luminance in the direction of the observer. This is the light returned by the retroreflective surface to the observer from the source, which in practice is the vehicle headlamp.5.2 This test method may be used as a measure of the nighttime performance of horizontally applied surfacing materials used on highway surfaces for lane markings and other traffic control purposes.5.3 Since this test method is a laboratory procedure, test specimens must be prepared so that they can be mounted on the specimen holder. Specimens measured by this laboratory method may be used as transfer standards for the calibration of portable instrumentation.5.4 Specimen selection and preparation may significantly influence the results of this test method.1.1 This test method describes the instrumental measurement of the retroreflective properties of horizontal surfacing materials, such as traffic stripe paint systems, traffic tapes, and traffic surface symbols.1.2 Specimen preparation, size, and shape must be determined and specified by the user of this test method. Likewise, the user must specify the observation and entrance angles to be used (see Fig. 1).FIG. 1 Diagram Illustrating Geometry for Measurement of Horizontal Coatings SpecimensNOTE 1: Includes observation angle α, entrance angle β, viewing angle νa, co-viewing angle νc, and co-entrance angle βc. The retroreflector axis, illumination axis, and observation axis all lie in the same plane.1.3 The geometric requirements of this test method are based on materials for which the relative retroreflectance changes less than approximately 50 % over the observation angle range from 0.2 to 0.5°. This is illustrated in Fig. 2.FIG. 2 Illustration of Typical Rate of Change of Retroreflectance Versus Observation Angle for Horizontal Retroreflective Material Measured at 86° Entrance Angle1.4 This test method is a laboratory test and requires a facility that can be darkened sufficiently so that stray light does not affect the test results. This facility must be capable of housing the required 15-m test distance.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D4061-13(2018)
标准名称:
Standard Test Method for Retroreflectance of Horizontal Coatings
英文名称:
Standard Test Method for Retroreflectance of Horizontal Coatings标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI X9.100-140-2018 Financial Services - Image Replacement Document - IRD
- ANSI X9.100-180-2006 (S2018) Specifications for Electronic Exchange of Check and Image Data (non-domestic) (Formerly published as DSTU X9.37-2003)
- ANSI X9.100-188-2018 Financial Services - Return Reasons for Check - Image Exchange and IRDs
- ANSI X9.112-3-2018 Wireless Management and Security - Part 3: Mobile
- ANSI X9.84-2018 Biometric Information Management and Security for the Financial Services Industry
- ANSI/OPEI B175.6-2018 Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Hedge Trimmers - Safety and Environmental Requirements
- AS 1085.13-1998 Railway permanent way material Spring fastening spikes for sleeper plates
- AS 1366.1-1992 (R2018)/Amdt 1-1992 Rigid cellular plastics sheets for thermal insulation - Rigid cellular polyurethane (RC/PUR)
- AS 1366.3-1992 (R2018)/Amdt 1-1993 Rigid cellular plastics sheets for thermal insulation - Rigid cellular polystyrene - Moulded (RC/PS - M)
- AS 1684.2 N3 Supp 13-1999 Residential timber-framed construction Non-cyclonic areas - N3 Supplement 13: Timber framing span tables - Wind classification N3 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.2-1999)
- AS 1684.2 N4 Supp 13-2006 Residential timber-framed construction Non-cyclonic areas - N4 Supplement 13: Timber framing span tables - Wind classification N4 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.2-2006)
- AS 1684.2 N4 Supp 13-2010 Residential timber-framed construction Non-cyclonic areas - N4 Supplement 13: Timber framing span tables - Wind classification N4 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.2-2010)
- AS 1684.3 C1 Supp 13-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 13: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.3-2006)
- AS 1684.3 C2 Supp 13-2006 Residential timber-framed construction Cyclonic areas - C2 Supplement 13: Timber framing span tables - Wind classification C2 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.3-2006)
- AS 1684.3 C3 Supp 13-1999 Residential timber-framed construction Cyclonic areas - C3 Supplement 13: Timber framing span tables - Wind classification C3 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.3-1999)