
【国外标准】 Standard Test Method for Hydrazine in Water
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Hydrazine is a man-made chemical and is not found in natural waters. The determination of hydrazine is usually made on boiler feedwaters, process waters, and other waters that have been treated with hydrazine (N2H4) for the purpose of maintaining residuals to prevent corrosion by dissolved oxygen. This reducing chemical reacts with dissolved oxygen to form nitrogen and water. However, under certain conditions it can also decompose to form ammonia and nitrogen. Hydrazine is used extensively as a preboiler treatment chemical for high-pressure boilers to scavenge small amounts of dissolved oxygen that are not removed by mechanical aeration. It has the advantage over sulfite treatment in that it does not produce any dissolved solids in the boiler water. Hydrazine is often determined in concentrations below 0.1 mg/L. However, in layup solutions for the protection of idle boilers, hydrazine may be present in concentrations as high as 200 mg/L.5.2 Additionally, hydrazine provides protection where reducing conditions are required, particularly in mixed metallurgy systems for the protection of the copper alloys.5.3 Hydrazine is a suspected carcinogen and a threshold limit value in the atmosphere of 1.0 mg/L has been set by OSHA. When in an aqueous solution, hydrazine will oxidize to nitrogen and water in the presence of air over a relatively short period of time.1.1 This test method covers2 the colorimetric determination of hydrazine in boiler feed waters, condensates, natural, and well waters that have been treated with hydrazine (N2H4). This test method is usable in the range from 5.0 to 200 μg/L (ppb) hydrazine. The range is for photometric measurements made at 458 nm in 50 mm cell. Higher concentrations of hydrazine can also be determined by taking a more diluted sample.1.2 It is the users’ responsibility to ensure the validity of this test method for untested types of waters.1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see 5.3, 8.4, and Footnote 5.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D1385-07(2018)e1
标准名称:
Standard Test Method for Hydrazine in Water
英文名称:
Standard Test Method for Hydrazine in Water标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 1338.1:1992/Amdt 1:1994 Filters for eye protectors - Filters for protection against radiation generated in welding and allied operations
- AS/NZS 13818.1 Supp 1:1999 Information technology - Generic coding of moving pictures and associated audio information Systems - Registration procedures (Supplement to AS/NZS 13818.1:1997)
- AS/NZS 13818.2 Supp 1:1999 Information technology - Generic coding of moving pictures and associated audio information Video - Registration of copyright identifiers (Supplement to AS/NZS 13818.2:1997)
- AS/NZS 1429.1:2000/Amdt 1:2002 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
- AS/NZS 1554.1:1995/Amdt 1:1998 Structural steel welding - Welding of steel structures
- AS/NZS 1554.3:2002/Amdt 1:2003 Structural steel welding Welding of reinforcing steel
- AS/NZS 1595:1998 (R2016)/Amdt 1:2014 Cold-rolled, unalloyed, steel sheet and strip
- AS/NZS 1660.2.1:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application
- AS/NZS 1660.2.4:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to polyethylene and polypropylene materials
- AS/NZS 1660.2.5:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to cables above 1 kV
- AS/NZS 1660.5.6:1998/Amdt 1:2001 Test methods for electric cables, cords and conductors - Fire tests - Test for combustion propagation
- AS/NZS 1664.1 Supp 1:1997/Amdt 1:1999 Aluminium structures - Limit state design - Commentary (Supplement to AS/NZS 1664.1:1997)
- AS/NZS 1664.1:1997/Amdt 1:1999 Aluminium structures - Limit state design (Reconfirmed 2020)
- AS/NZS 1664.2 Supp 1:1997/Amdt 1:1999 Aluminium structures - Allowable stress design - Commentary (Supplement to AS/NZS 1664.2:1997) (Reconfirmed 2020)
- AS/NZS 1664.2:1997/Amdt 1:1999 Aluminium structures - Allowable stress design (Reconfirmed 2020)