【国外标准】 Standard Specification for Polyoxymethylene (Acetal) for Medical Applications

本网站 发布时间: 2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!   查看详情>>
标准简介标准简介

适用范围:

This specification covers polyoxymethylene (acetal) resin for medical applications. This specification provides requirements and associated test methods for a form of this thermoplastic which is intended for use in manufacturing medical devices, instrumentation or components thereof. Physical and mechanical properties of medical grade polyoxymethylene such as specific gravity, water absorption, equilibrium, tensile yield strength, tensile elongation break, tensile modulus, tensile impact strength, compressive strength, and sheer strength shall be determined. Biocompatibility of acetal resins and implant devices made using these materials shall also be determined.1.1 This specification covers polyoxymethylene (acetal) resin for medical applications. This specification provides requirements and associated test methods for a form of this thermoplastic which is intended for use in manufacturing medical devices, instrumentation or components thereof.1.2 As with any material, some characteristics may be altered by the processing techniques (such as molding, extrusion, machining, sterilization, and so forth) required for a specific application. Therefore properties of fabricated forms of this resin should be evaluated using appropriate test methods to assure safety and efficacy.1.3 Although this resin has been used for specific implant applications in the United States, the use of this resin in medical devices should be restricted to non-implant applications until biocompatibility evaluations appropriate for the intended applications are successfully completed.1.4 The biocompatibility of plastic compounds made up of polyoxymethylene (acetal) resin containing colorants, fillers, processing aids, or other additives as well as polymer blends which contain polyacetal should not be assumed on the basis of resin biocompatibility alone. Their biocompatibility must be established by testing the final (end-use) compositions using evaluation methods appropriate for the intended applications. It should be noted that the types, test levels, and biological effects of extractives yielded by the additives contained in a compound or blend may also have to be evaluated for some end-use applications.1.5 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.

基本信息

  • 标准号:

    ASTM F1855-00(2019)

  • 标准名称:

    Standard Specification for Polyoxymethylene (Acetal) for Medical Applications

  • 英文名称:

    Standard Specification for Polyoxymethylene (Acetal) for Medical Applications
  • 标准状态:

    Active
  • 发布日期:

  • 实施日期:

  • 出版语种:

标准分类号

  • 标准ICS号:

    11.040.30,83.080.20
  • 中标分类号:

关联标准

  • 替代以下标准:

  • 被以下标准替代:

  • 引用标准:

  • 采用标准:

出版信息

  • 页数:

    3 页
  • 字数:

  • 开本:

其他信息

  • 起草人:

  • 起草单位:

  • 归口单位:

    F04.11
  • 提出部门:

  • 发布部门:

  • 推荐标准
Baidu
map