【国外标准】 Standard Practice for Surface Preparation and Marking of Metallic Surgical Implants
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
3.1 The objective of surface treatments as documented in this practice is to improve the corrosion resistance of metallic surgical implants including, but not limited to, those manufactured from iron, cobalt, nickel, titanium, and tantalum base materials.3.2 Iron particles, ceramic media, and other foreign particles may become smeared over or embedded into the surface of implants during processing operations such as forming, machining, tumbling, media blasting, marking, and so forth. These particles should be removed to minimize localized corrosion and superficial blemishes.3.3 The various chemical and electrochemical surface treatments specified by this practice are used to remove objectionable surface contaminants and to restore maximum corrosion resistance to, or promote the creation of, an inert or passive surface, such as a metal oxide film, as is applicable to the specific material. Some of these treatments are referred to as passivation treatments. The preferred surface treatment for a given application varies depending on the implant material and the nature of the surface contaminants.3.4 Depending on the implant, its material, and the type of marking method and procedure, the marking may be applied before or after a chemical or electrochemical surface treatment. When marking is performed after the surface treatment, the localized implant surface shall be evaluated to determine if there is a need for additional surface treatment.NOTE 1: The need for additional surface treatment is likely for stainless steel with all marking methods, and for nonferrous alloys when the marking method involves direct or second-hand contact with iron-based or other material that would be considered an objectionable surface contaminant.3.5 The selection of procedures to be applied to the implants, and additional requirements which are not covered by this practice, may be included in the implant production specification.1.1 This practice provides descriptions of surface characteristics, surface preparation, and marking for metallic surgical implants, with the purpose of improving the corrosion resistance of the implant surfaces and markings.1.2 Marking nomenclature and neutralization of endotoxin are not specified in this practice (see X1.4).1.3 Surface requirements and marking methods included in the implant specification shall take precedence over requirements listed in this practice, where appropriate.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F86-21
标准名称:
Standard Practice for Surface Preparation and Marking of Metallic Surgical Implants
英文名称:
Standard Practice for Surface Preparation and Marking of Metallic Surgical Implants标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F3275-22 Standard Guide for Using a Force Tester to Evaluate Performance of a Brush Part Designed to Clean the Internal Channel of a Medical Device
- ASTM F3276-22 Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device
- ASTM F3277-19 Standard Specification for Cantilevered Steel Bunks Used in Detention and Correctional Facilities
- ASTM F3283/F3283M-18 Standard Specification for the Manufacturing of High-Voltage Proximity Alarm to be used for the Detection of Overhead High Voltage Alternating Current (AC)
- ASTM F3288/F3288M-20 Standard Specification for MRS-Rated Metric- and Inch-sized Crosslinked Polyethylene (PEX) Pressure Pipe
- ASTM F3292-19 Standard Practice for Inspection of Spinal Implants Undergoing Testing
- ASTM F3293-18 Standard Guide for Application of Test Soils for the Validation of Cleaning Methods for Reusable Medical Devices
- ASTM F3294-18 Standard Guide for Performing Quantitative Fluorescence Intensity Measurements in Cell-based Assays with Widefield Epifluorescence Microscopy
- ASTM F3295-18 Standard Guide for Impingement Testing of Total Disc Prostheses
- ASTM F330-21 Standard Test Method for Bird Impact Testing of Aerospace Transparent Enclosures
- ASTM F3300-23 Standard Test Method for Abrasion Resistance of Flexible Packaging Films Using a Reciprocating Weighted Stylus
- ASTM F3301-18a Standard for Additive Manufacturing – Post Processing Methods – Standard Specification for Thermal Post-Processing Metal Parts Made Via Powder Bed Fusion
- ASTM F3302-18 Standard for Additive Manufacturing – Finished Part Properties – Standard Specification for Titanium Alloys via Powder Bed Fusion
- ASTM F3306-19 Standard Test Method for Ion Release Evaluation of Medical Implants
- ASTM F3308/F3308M-19(2023) Standard Practice for Sampling and Testing Frequency for Recycled Materials in Polyethylene (PE) Pipe for Non-Pressure Applications