
【国外标准】 Standard Test Method for Hydraulic Pullout Resistance of a Geomembrane with Locking Extensions Embedded in Concrete
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Due to hydraulic pressure that may be present on some applications, engineers need to understand the capability of these products to resist this pressure. This test allows engineers to compare products and verify pullout strength.5.2 Hydraulic pullout resistance is a function of locking extension dimensions, locking extension geometry, locking extensions per area, locking extension polymer composition, and the properties of the concrete in which the locking extensions are embedded.5.3 The data from this test method provides comparative information for rating hydraulic pullout resistance of different geomembranes with locking extensions embedded in concrete. Hydraulic pullout resistance, while partly dependent on locking extension dimensions, has no simple correlation to locking extension dimensions and geometry. Hence, hydraulic pullout resistance cannot be determined with a small sample without potentially producing misleading data to the actual hydraulic pullout resistance of the material. Therefore, the hydraulic pullout resistance is expressed in kPa (lb/ft2).5.4 The apparatus can be circular or square in nature and must have a test area of 0.36 m2 (558 in.2).5.5 Fig. 1 shows an example of a circular test apparatus that can be used in the performance of this test. The apparatus requires a pressure vessel rated to a minimum 690 kPa (14 410 lb/ft2). The vessel test diameter should be a minimum of 677.04 mm (26.655 in.) as shown in Fig. 1.FIG. 1 Picture of Circular Test ApparatusNOTE 1: Larger vessels may be used but it is up to user to establish correlation to the standard size vessel. The use of a smaller diameter vessel than denoted in this standard may contribute to higher pullout resistance due to thickness or stiffness of some products.5.6 Test Pedestal—The base of the testing apparatus which holds the test specimen.5.7 Upper Flange—Is the flange that is bolted down on top of specimen to create a seal.5.8 Form—Is an aluminum ring used to form test specimen as shown in Fig. 2.FIG. 2 Bottom of Form with Studs Facing Up and Cylinder Spacer5.9 Specimen Ring—The solid ring that is placed around test specimen to contain leakage through the concrete.5.10 The vessel will have a system to measure pressure.5.10.1 The system for measuring pressure shall be capable of being read to an accuracy of 3.5 kPa (0.5 psi).5.11 Concrete shall be a ready-mixed concrete per Specification C94/C94M with a minimum cured compressive strength of 34 473.8 kPa (5 000 psi).NOTE 2: Alternate concrete or grout mixtures may be used for project-specific applications with the approval of the owner or engineer.5.12 All tests shall be conducted at standard laboratory temperatures of 23 ± 2 °C (73.4 ± 3.6 °F).1.1 This test method covers the determination of the hydraulic pullout resistance of a geomembrane with locking extensions embedded in concrete by determining the pressure required for locking extensions of the embedded specimen to pullout of the concrete.1.2 The values stated in SI units are to be regarded as standard. The values given in parentheses are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D7853-13(2020)
标准名称:
Standard Test Method for Hydraulic Pullout Resistance of a Geomembrane with Locking Extensions Embedded in Concrete
英文名称:
Standard Test Method for Hydraulic Pullout Resistance of a Geomembrane with Locking Extensions Embedded in Concrete标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- INCITS 335-2000 (R2020) Information technology - Small Computer System Interface (SCSI-3) Stream Commands (SSC)
- INCITS 378:2009/AM 1:2010 (R2020) Information Technology - Finger Minutiae Format for Data Interchange - Amendment 1
- INCITS 410:2015 (R2020) Information Technology - Identification Cards - Limited Use (LU), Proximity Integrated Circuit Card (PICC)
- INCITS 440:2015 (R2020) Information Technology Card Durability / Service Life
- INCITS 452-2009/AM 1:2010 (R2020) Information Technology - AT Attachment-8 ATA/ATAPI Command Set (ATA8-ACS) - Amendment 1
- INCITS 462-2010 (S2020) Information Technology - Fibre Channel - Backbone - 5 (FC-BB-5)
- INCITS 463-2010 (S2020) Information Technology - Fibre Channel - Generic Services - 6 (FC-GS-6)
- INCITS 464-2010 (S2020) Information Technology - Information Management - Extensible Access Method (XAM)
- INCITS 469-2015 (R2020) Information technology - Open Virtualization Format (OVF) specification
- INCITS 513-2015 (R2020) Information technology SCSI Primary Commands 4 (SPC-4)
- INCITS 547-2020 Information Technology - Fibre Channel - Switch Fabric - 7 (FC-SW-7)
- INCITS 548-2020 Information Technology - Fibre Channel - Generic Services - 8 (FC-GS-8)
- INCITS 553-2020 Information Technology Fibre Channel Link Services - 4 (FC-LS-4)
- INCITS 556-2020 Information Technology - Non-Volatile Memory Express - 2 (FC-NVMe-2)
- INCITS 559-2020 Information Technology - Fibre Channel - Physical Interface-7P (FC-PI-7P)