
【国外标准】 Standard Test Method to Determine Melting Temperature of Synthetic Fibers
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Either of these two test methods is used to determine the temperature at which a synthetic fiber specimen changes from a solid to a liquid-like state. 5.1.1 Synthetic fibers may be either amorphous or semi-crystalline thermoplastics or thermosets. Synthetic fibers may change from the solid to a liquid-like state on heating because of the glass transition of amorphous polymers, the melting of crystalline regions of semi-crystalline polymers, or at the onset of degradation. Thermoplastic fibers consist of crystalline and amorphous regions and may be manufactured with a range of molecular weights. The amorphous and crystalline fiber structure and variable molecular weight can lead to a melting temperature range instead of a discreet melting point (see Table X1.1). 5.2 This test method is considered satisfactory for acceptance testing of commercial shipments. 5.2.1 If there are differences of practical significance between reported test results for two or more laboratories, perform comparative testing to determine if there is a statistical bias between them, using competent statistical assistance. As a minimum, use the samples for such a comparative test that are as homogeneous as possible, drawn from the same lot of material as the samples that resulted in disparate results during initial testing and randomly assigned in equal numbers to each laboratory. Compare the test results from the laboratories involved using a statistical test for unpaired data, at a probability level chosen prior to the testing series. If bias is found, either its cause must be found and corrected, or future test results for that material must be adjusted in consideration of the known bias. 5.3 This test method is suitable for quality control testing of synthetic fibers and product comparisons of different fibers by manufacturers, retailers, and users. 5.4 If the test method is used to identify fiber material type, it is important to test a known reference material at the same laboratory with the same test method to confirm the fiber identification. In addition, since some fiber types have similar melting temperatures or overlapping melting temperature ranges as show in Table X1.1, secondary methods for fiber identification as described in Test Methods D276 will be required to make fiber identifications. 1.1 Either of two test methods are used to determine the melting temperature of thermoplastic fibers, yarns, or threads. 1.2 Method 1 can be used to determine melting temperatures for blends of multiple fiber material types. Method 2 can only be used to determine the melting temperature of a single fiber material type. 1.2.1 Method 1, Differential Scanning Calorimetry (DSC), measures changes in heat capacity and will detect the glass transition, the crystalline melting and endothermic thermal degradation. 1.2.2 Method 2, a visual determination of melting, determines any change that visually appears as a transition from a solid to a liquid state. 1.2.3 Due to the differences in what each test method measures, the results from Method 1 and Method 2 cannot be compared. 1.3 The values stated in either SI units or other units are to be regarded separately. The values stated in each system are not exact equivalents; therefore, each system shall be used independently without combining values. 1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM D7138-16
标准名称:
Standard Test Method to Determine Melting Temperature of Synthetic Fibers
英文名称:
Standard Test Method to Determine Melting Temperature of Synthetic Fibers标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 2350.16:2006 (R2016)/Amdt 1:2008 Methods of testing portland, blended and masonry cements Determination of air content of masonry cement
- AS/NZS 3350.2.16:1996/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements - Food waste disposers (IEC 60335-2-15:1994, MOD)
- AS/NZS 3580.16:2014 Methods for sampling and analysis of ambient air Determination of polycyclic aromatic hydrocarbons (PAH)
- AS/NZS 3750.16:1998 (R2013) Paints for steel structures Waterborne primer and paint for galvanized, zinc/aluminium alloy-coated and zinc-primed steel
- AS/NZS 3905.16:1998 Quality system guidelines Guidelines to quality in project management
- AS/NZS 4387.16:1996 Domestic kitchen assemblies - Methods of test Determination of calibration of drawer slamming apparatus
- AS/NZS 4524.16:1998 Bonded abrasive products - Dimensions Grinding wheels for cutting-off on an angle grinder
- AS/NZS 61000.4.16:2002/Amdt 1:2012 Electromagnetic compatibility (EMC) Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
- AS/NZS 61558.2.16:2010 (IEC TEXT)/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS 61558.2.16:2010/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS CISPR 16.1.1:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.1:2006 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.2:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances
- AS/NZS CISPR 16.1.3:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Disturbance power
- AS/NZS CISPR 16.1.4:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Radiated disturbances