
【国外标准】 Standard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food Processing (Withdrawn 2018)
本网站 发布时间:
2024-02-28
- ASTM ISO/ASTM51431-05
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, insect disinfestation, growth and maturation inhibition, and shelf-life extension. Food irradiation specifications almost always include a minimum or a maximum limit of absorbed dose, sometimes both: a minimum limit may be set to ensure that the intended beneficial effect is achieved and a maximum limit may be set for the purpose of avoiding product or packaging degradation. For a given application, one or both of these values may be prescribed by government regulations that have been established on the basis of scientific data. Therefore, prior to the irradiation of the food product, it is necessary to determine the capability of an irradiation facility to consistently deliver the absorbed dose within any prescribed limits. Also, it is necessary to monitor and document the absorbed dose during each production run to verify compliance with the process specifications at a predetermined level of confidence.NOTE 3 - The Codex Alimentarius Commission has developed an international General Standard and a Code of Practice that address the application of ionizing radiation to the treatment of foods and that strongly emphasize the role of dosimetry for ensuring that irradiation will be properly performed (1).44.2 For more detailed discussions of radiation processing of various foods, see Guides F 1355, F 1356, F 1736, and F 1885 and Refs (2-15).4.3 Accelerator-generated radiation can be in the form of electrons or X-rays produced by the electrons. Penetration of radiation into the product required to accomplish the intended effect is one of the factors affecting the decision to use electrons or X-rays.4.4 To ensure that products are irradiated within a specified dose range, routine process control requires routine product dosimetry, documented product handling procedures (before, during and after the irradiation), consistent orientation of the products during irradiation, monitoring of critical operating parameters, and documentation of all relevant activities and functions.1.1 This practice outlines the installation qualification program for an irradiator and the dosimetric procedures to be followed during operational qualification, performance qualification and routine processing in facilities that process food with high-energy electrons and X-rays (bremsstrahlung) to ensure that product has been treated within a predetermined range of absorbed dose. Other procedures related to operational qualification, performance qualification and routine processing that may influence absorbed dose in the product are also discussed. Information about effective or regulatory dose limits for food products, and appropriate energy limits for electron beams used directly or to generate X-rays is not within the scope of this practice (see ASTM Guides F 1355, F 1356, F 1736, and F 1885).Note 1Dosimetry is only one component of a total quality assurance program for adherence to good manufacturing practices used in the production of safe and wholesome food.Note 2ISO/ASTM Practice 51204 describes dosimetric procedures for gamma irradiation facilities for food processing.1.2 For guidance in the selection and calibration of dosimetry systems, and interpretation of measured absorbed dose in the product, see ISO/ASTM Guide 51261 and ASTM Practice E 666. For the use of specific dosimetry systems, see ASTM Practices E 1026 and E 2304, and ISO/ASTM Practices 51205, 51275, 51276, 51310, 51401, 51538, 51540, 51607, 51650 and 51956. For discussion of radiation dosimetry for electrons and X-rays also see ICRU Reports 35 and 14. For discussion of radiation dosimetry for pulsed radiation, see ICRU Report 34.1.3 While gamma radiation from radioactive nuclides has discrete energies, X-rays (bremsstrahlung) from machine sources cover a wide range of energies, from low values (about 35 keV) to the energy of the incident electron beam. For information concerning electron beam irradiation technology and dosimetry, see ISO/ASTM Practice 51649. For information concerning X-ray irradiation technology and dosimetry, see ISO/ASTM Practice 51608.This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM ISO/ASTM51431-05
标准名称:
Standard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food Processing (Withdrawn 2018)
英文名称:
Standard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food Processing (Withdrawn 2018)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS ISO 10006-2003 Quality management systems - Guidelines for quality management in projects
- AS ISO 10014-2007 Quality management systems - Guidelines for realizing financial and economic benefits
- AS ISO 10993.10-2002 Biological evaluation of medical devices Tests for irritation and sensitization
- AS ISO 10993.12-2002 Biological evaluation of medical devices Sample preparation and reference materials
- AS ISO 11137-2002 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization
- AS ISO 12647.1:2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Parameters and measurement methods
- AS ISO 12647.2-2008 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Offset lithographic processes
- AS ISO 12647.7:2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Proofing processes working directly from digital data
- AS ISO 12647.8-2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Validation print processes working directly from digital data
- AS ISO 13485-2003 Medical devices - Quality management systems - Requirements for regulatory purposes
- AS ISO 13488-2002 Quality systems - Medical devices - Particular requirements for the application of ISO 9002
- AS ISO 13916-2003 Welding - Guide on the measurement of preheating temperature, interpass temperature and preheat maintenance temperature
- AS ISO 140.8-2006 Acoustics - Measurement of sound insulation in buildings and of building elements Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor
- AS ISO 14021(Int)-1998 Environmental labels and declarations - Self-declared environmental claims
- AS ISO 14155-2002 Clinical investigation of medical devices