
【国外标准】 Standard Practice for Dosimetry in a Gamma Facility for Radiation Processing
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 Various products and materials routinely are irradiated at predetermined doses in gamma irradiation facilities to reduce their microbial population or to modify their characteristics. Dosimetry requirements may vary depending upon the irradiation application and end use of the product. Some examples of irradiation applications where dosimetry may be used are:4.1.1 Sterilization of medical devices,4.1.2 Treatment of food for the purpose of parasite and pathogen control, insect disinfestation, and shelf life extension,4.1.3 Disinfection of consumer products,4.1.4 Cross-linking or degradation of polymers and elastomers,4.1.5 Polymerization of monomers and grafting of monomers onto polymers,4.1.6 Enhancement of color in gemstones and other materials,4.1.7 Modification of characteristics of semiconductor devices, and4.1.8 Research on materials effects.NOTE 3: Dosimetry is required for regulated irradiation processes such as sterilization of medical devices and the treatment of food. It may be less important for other industrial processes, for example, polymer modification, which can be evaluated by changes in the physical and chemical properties of the irradiated materials.4.2 An irradiation process usually requires a minimum absorbed dose to achieve the intended effect. There also may be a maximum absorbed dose that the product can tolerate and still meet its functional or regulatory specifications. Dosimetry is essential to the irradiation process since it is used to determine both of these limits and to confirm that the product is routinely irradiated within these limits.4.3 The absorbed-dose distribution within the product depends on the overall product dimensions and mass, irradiation geometry, and source activity distribution.4.4 Before an irradiation facility can be used, it must be qualified to determine its effectiveness in reproducibly delivering known, controllable absorbed doses. This involves testing the process equipment, calibrating the equipment and dosimetry system, and characterizing the magnitude, distribution and reproducibility of the absorbed dose delivered by the irradiator for a range of product densities.4.5 To ensure consistent and reproducible dose delivery in a qualified process, routine process control requires documented product handling procedures before and after irradiation, consistent product loading configuration, control and monitoring of critical process parameters, routine product dosimetry and documentation of the required activities.1.1 This practice outlines the installation qualification program for an irradiator and the dosimetric procedures to be followed during operational qualification, performance qualification, and routine processing in facilities that process products with ionizing radiation from radionuclide gamma sources to ensure that product has been treated within a predetermined range of absorbed dose. Other procedures related to operational qualification, performance qualification, and routine processing that may influence absorbed dose in the product are also discussed.NOTE 1: Dosimetry is only one component of a total quality assurance program for adherence to good manufacturing practices used in radiation processing applications.NOTE 2: ISO/ASTM Practices 51818 and 51649 describe dosimetric procedures for low and high enery electron beam facilities for radiation processing and ISO/ASTM Practice 51608 describes procedures for X-ray (bremsstrahlung) facilities for radiation processing.1.2 For the radiation sterilization of health care products, see ISO 11137-1. In those areas covered by ISO 11137-1, that standard takes precedence.1.3 This document is one of a set of standards that provides recommendations for properly implementing and utilizing dosimetry in radiation processing. It is intended to be read in conjunction with ASTM Practice E2628.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM ISO/ASTM51702-13(2021)
标准名称:
Standard Practice for Dosimetry in a Gamma Facility for Radiation Processing
英文名称:
Standard Practice for Dosimetry in a Gamma Facility for Radiation Processing标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 4276.13-1995 Water microbiology Pseudomonas aeruginosa - Membrane filtration method
- AS 4969.13-2009 Analysis of acid sulfate soil - Dried samples - Methods of test Determination of acid neutralizing capacity by back-titration (ANCBT)
- AS 5013.13(Int)-2010 Food microbiology Milk and milk products - Detection of Enterobacter sakazakii
- AS ISO 10006-2003 Quality management systems - Guidelines for quality management in projects
- AS ISO 10014-2007 Quality management systems - Guidelines for realizing financial and economic benefits
- AS ISO 10993.10-2002 Biological evaluation of medical devices Tests for irritation and sensitization
- AS ISO 10993.12-2002 Biological evaluation of medical devices Sample preparation and reference materials
- AS ISO 11137-2002 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization
- AS ISO 12647.1:2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Parameters and measurement methods
- AS ISO 12647.2-2008 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Offset lithographic processes
- AS ISO 12647.7:2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Proofing processes working directly from digital data
- AS ISO 12647.8-2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Validation print processes working directly from digital data
- AS ISO 13485-2003 Medical devices - Quality management systems - Requirements for regulatory purposes
- AS ISO 13488-2002 Quality systems - Medical devices - Particular requirements for the application of ISO 9002
- AS ISO 13916-2003 Welding - Guide on the measurement of preheating temperature, interpass temperature and preheat maintenance temperature