【国外标准】 Standard Test Method for Total Fluorine, Chlorine, and Sulfur in Liquid Petroleum Gas (LPG) by Oxidative Pyrohydrolytic Combustion Followed by Ion Chromatography Detection (Combustion Ion Chromatography-CIC)
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The total fluorine, chlorine, and sulfur contained in LPG, similar low molecular weight hydrocarbons, and DME can be harmful to many catalytic chemical processes, lead to corrosion, and contribute to pollutant emissions. While LPG specifications limit sulfur, some specifications also contain precautionary statements about fluorine. Chlorine has been known to contaminate LPG with detrimental consequences. This test method can be used to determine total fluorine (as fluoride), chlorine (as chloride), and sulfur (as sulfate ion) in process streams, intermediate and finished LPG products, similar low molecular weight hydrocarbons, and DME (1.1).1.1 This test method covers the individual determination of total fluorine, chlorine, and sulfur in liquid petroleum gas (LPG), low molecular weight hydrocarbons, their mixtures, and dimethyl ether (DME) in the range of 1 mg/kg to 300 mg/kg fluorine and sulfur and 5 mg/kg to 300 mg/kg for chlorine. This test method is applicable to products described in Specifications D1835 and D7901 and it can be applicable to process streams with similar properties to LPG and other materials such as butylene, propylene, and olefins.1.2 This test method can also be applied to the measurement of the bromine and iodine in samples covered by the scope of this test method, but the precision and bias statement of this test method is not applicable to these halides.1.3 This test method can be applied to sample concentrations outside the scope of this test method through adjustments of sample injection volume or number of injections combusted (or both), adjustment of injection volume to the ion chromatograph, and adjustment of the final dilution volume of the absorbing solution prior to injection to the ion chromatograph. The precision and scope of this test method is not applicable to samples that are outside the scope of the method.1.4 The values stated in SI units are to be regarded as standard.1.4.1 Exception—Values given in parentheses are for information only.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 9.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D7994-17
标准名称:
Standard Test Method for Total Fluorine, Chlorine, and Sulfur in Liquid Petroleum Gas (LPG) by Oxidative Pyrohydrolytic Combustion Followed by Ion Chromatography Detection (Combustion Ion Chromatography-CIC)
英文名称:
Standard Test Method for Total Fluorine, Chlorine, and Sulfur in Liquid Petroleum Gas (LPG) by Oxidative Pyrohydrolytic Combustion Followed by Ion Chromatography Detection (Combustion Ion Chromatography-CIC)标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 5013.17-2004 Food microbiology Milk and milk products - General guidance for the preparation of test samples, initial suspensions and decimal dilutions for microbiological examination
- AS/NZS 3200.2.17:1994/Amdt 1:1997 Approval and test specification - Medical electrical equipment - Particular requirements for safety - Remote-controlled automatically-driven gamma-ray afterloading equipment
- AS/NZS 3350.2.17:2000/Amdt 1:2001 Safety of household and similar electrical appliances Particular requirements - Blankets, pads and similar flexible heating
- AS/NZS 3350.2.17:2000/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements - Blankets, pads and similar flexible heating appliances (IEC 60335-2-17:1998, MOD)
- AS/NZS 4456.17:2003/Amdt 1:2004 Masonry units, segmental pavers and flags - Methods of test Determining initial rate of absorption (suction)
- AS/NZS 60079.17:2009/Amdt 1:2011 Explosive atmospheres Electrical installations inspection and maintenance
- AS/NZS 60335.2.17:2004/Amdt 2:2009 Household and similar electrical appliances - Safety Particular requirements for blankets, pads, clothing and similar flexible heating appliances (IEC 60335-2-17 Ed 2.2, MOD)
- AS/NZS 60598.2.17:2006 Luminaires Particular requirements - Luminaires for stage lighting, television, film and photographic studios (outdoor and indoor)(IEC 60598.2.17, Ed. 1.0 (1984) MOD)
- AS/NZS 60745.2.17:2003 Hand-held motor-operated electric tools - Safety - Particular requirements for routers and trimmers
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
- ASTM A1-00(2018) Standard Specification for Carbon Steel Tee Rails
- ASTM A1000/A1000M-17(2023) Standard Specification for Steel Wire, Carbon and Alloy Specialty Spring Quality
- ASTM A1001-18 Standard Specification for High-Strength Steel Castings in Heavy Sections
- ASTM A1002-16(2020) Standard Specification for Castings, Nickel-Aluminum Ordered Alloy