
【国外标准】 Standard Test Method for Nondestructive Assay of Special Nuclear Material in Low-Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Segmented gamma-ray scanning provides a nondestructive means of measuring the nuclide content of scrap and waste where the specific nature of the matrix and the chemical form and relationship between the nuclide and matrix may be unknown.5.2 The procedure can serve as a diagnostic tool that provides a vertical profile of transmission and nuclide concentration within the item.5.3 Item preparation is generally limited to good waste/scrap segregation practices that produce relatively homogeneous items that are required for any successful waste/inventory management and assay scheme, regardless of the measurement method used. Also, process knowledge should be used, when available, as part of a waste management program to complement information on item parameters, container properties, and the appropriateness of calibration factors.5.4 To obtain the lowest detection levels, a two-pass assay should be used. The two-pass assay also reduces problems related to potential interferences between transmission peaks and assay peaks. For items with higher activities, a single-pass assay may be used to increase throughput.1.1 This test method covers the transmission-corrected nondestructive assay (NDA) of gamma-ray emitting special nuclear materials (SNMs), most commonly 235U, 239Pu, and 241Am, in low-density scrap or waste, packaged in cylindrical containers. The method can also be applied to NDA of other gamma-emitting nuclides including fission products. High-resolution gamma-ray spectroscopy is used to detect and measure the nuclides of interest and to measure and correct for gamma-ray attenuation in a series of horizontal segments (collimated gamma detector views) of the container. Corrections are also made for counting losses occasioned by signal processing limitations (1-3).21.2 There are currently several systems in use or under development for determining the attenuation corrections for NDA of radioisotopic materials (4-8). A related technique, tomographic gamma-ray scanning (TGS), is not included in this test method (9, 10, 11).1.2.1 This test method will cover two implementations of the Segmented Gamma Scanning (SGS) procedure: (1) Isotope Specific (Mass) Calibration, the original SGS procedure, uses standards of known radionuclide masses to determine detector response in a mass versus corrected count rate calibration that applies only to those specific radionuclides for which it is calibrated, and (2) Efficiency Curve Calibration, an alternative method, typically uses non-SNM radionuclide sources to determine system detection efficiency vs. gamma energy and thereby calibrate for all gamma-emitting radionuclides of interest (12).1.2.1.1 Efficiency Curve Calibration, over the energy range for which the efficiency is defined, has the advantage of providing calibration for many gamma-emitting nuclides for which half-life and gamma emission intensity data are available.1.3 The assay technique may be applicable to loadings up to several hundred grams of nuclide in a 208-L [55-gal] drum, with more restricted ranges to be applicable depending on specific packaging and counting equipment considerations.1.4 Measured transmission values must be available for use in calculation of segment-specific attenuation corrections at the energies of analysis.1.5 A related method, SGS with calculated correction factors based on item content and density, is not included in this standard.1.6 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 10.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM C1133/C1133M-10(2018)
标准名称:
Standard Test Method for Nondestructive Assay of Special Nuclear Material in Low-Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning
英文名称:
Standard Test Method for Nondestructive Assay of Special Nuclear Material in Low-Density Scrap and Waste by Segmented Passive Gamma-Ray Scanning标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 4629-2005 (R2018)/Amdt 1-2007 Automatic shut off valves and vent valves
- AS 5013.10-2004/Amdt 1-2005 Food microbiology Microbiology of food and animal feeding stuffs - Horizontal method for the detection of Salmonella spp.
- AS ISO 10993.10-2002 Biological evaluation of medical devices Tests for irritation and sensitization
- AS/NZS 1580.481.1.10:1998 (R2013) Paints and related materials - Methods of test Coatings - Exposed to weathering - Degree of flaking and peeling
- AS/NZS 2098.10:1995 Methods of test for veneer and plywood Measurement of dimensions and shape for structural Laminated Veneer Lumber
- AS/NZS 3350.2.10:1996/Amdt 2:2001 Safety of household and similar electrical appliances Particular requirements - Floor treatment machines and wet scrubbing machines
- AS/NZS 3350.2.10:1996/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements - Floor treatment machines and wet scrubbing machines (IEC 60335-2-10:1992, MOD)
- AS/NZS 3580.9.10:2006 Methods for sampling and analysis of ambient air Determination of suspended particulate matter - PM2.5 low volume sampler - Gravimetric method
- AS/NZS 4266.10:1995 Reconstituted wood-based panels - Methods of test Determination of glue bond durability (boil test)
- AS/NZS 4266.10:1995/Amdt 1:1997 Reconstituted wood-based panels - Methods of test - Determination of glue bond durability (boil test)
- AS/NZS 4695.10.2:1997 Fire hazard testing of electrotechnical products Guidance and test methods for the minimization of the effects of abnormal heat on electrotechnical products involved in fires - Method for testing products made from non-metallic materials for resistance to heat using the ball pressure test
- AS/NZS 4695.2.10:1996 Fire hazard testing of electrotechnical products Test methods - Glow-wire test methods - General
- AS/NZS 60079.10.1:2009/Amdt 1:2013 Explosive atmospheres Classification of areas - Explosive gas atmospheres (IEC 60079-10-1, Ed.1.0(2008) MOD)
- ASTM E2264-23 Standard Practice for Determining the Effects of Temperature Cycling on Fenestration Products
- ASTM E2268-04(2023) Standard Test Method for Water Penetration of Exterior Windows, Skylights, and Doors by Rapid Pulsed Air Pressure Difference