适用范围:
4.1 Acidity and alkalinity measurements are used to assist in establishing levels of chemical treatment to control scale, corrosion, and other adverse chemical equilibria.4.2 Levels of acidity or alkalinity are critical in establishing solubilities of some metals, toxicity of some metals, and the buffering capacity of some waters.1.1 These test methods2 cover the determination of acidity or alkalinity of all types of water. Three test methods are given as follows: SectionsTest Method A (Electrometric Titration) 7 to 15Test Method B (Electrometric or Color-Change Titration) 16 to 24Test Method C (Color-Change Titration After HydrogenPeroxide Oxidation and Boiling) 25 to 331.2 In all of these test methods the hydrogen or hydroxyl ions present in water by virtue of the dissociation or hydrolysis of its solutes, or both, are neutralized by titration with standard alkali (acidity) or acid (alkalinity). Of the three procedures, Test Method A is the most precise and accurate. It is used to develop an electrometric titration curve (sometimes referred to as a pH curve), which defines the acidity or alkalinity of the sample and indicates inflection points and buffering capacity, if any. In addition, the acidity or alkalinity can be determined with respect to any pH of particular interest. The other two methods are used to determine acidity or alkalinity relative to a predesignated end point based on the change in color of an internal indicator or the equivalent end point measured by a pH meter. They are suitable for routine control purposes.1.3 When titrating to a specific end point, the choice of end point will require a careful analysis of the titration curve, the effects of any anticipated changes in composition on the titration curve, knowledge of the intended uses or disposition of the water, and a knowledge of the characteristics of the process controls involved. While inflection points (rapid changes in pH) are usually preferred for accurate analysis of sample composition and obtaining the best precision, the use of an inflection point for process control may result in significant errors in chemical treatment or process control in some applications. When titrating to a selected end point dictated by practical considerations, (1) only a part of the actual neutralizing capacity of the water may be measured, or (2) this capacity may actually be exceeded in arriving at optimum acidity or alkalinity conditions.1.4 A scope section is provided in each test method as a guide. It is the responsibility of the analyst to determine the acceptability of these test methods for each matrix.1.5 Former Test Methods C (Color-Comparison Titration) and D (Color-Change Titration After Boiling) were discontinued. Refer to Appendix X4 for historical information.1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM D1067-16
标准名称:
Standard Test Methods for Acidity or Alkalinity of Water
英文名称:
Standard Test Methods for Acidity or Alkalinity of Water标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 1038.16-1996 Coal and coke - Analysis and testing Assessment and reporting of results
- AS 1085.16-1995 Railway permanent way material Cast sleeper plates
- AS 1141.16-1995 Methods for sampling and testing aggregates Angularity number
- AS 1807.16-2000 Cleanrooms, workstations, safety cabinets and pharmaceutical isolators - Methods of test Determination of sound level in cleanrooms
- AS 2001.7.16-1983 Methods of test for textiles Quantitative analysis of fibre mixtures - Binary mixtures of jute and certain animal fibres (method of determining the nitrogen content)
- AS 2362.16-1990 Automatic fire detection and alarm systems - Methods of test for actuating devices Impact test
- AS 2550.16-1997 Cranes- Safe use Mast climbing work platforms
- AS 3730.16-1991 Guide to the properties of paints for buildings Latex - Timber finish - Exterior
- ASTM D3550/D3550M-17 Standard Practice for Thick Wall, Ring-Lined, Split Barrel, Drive Sampling of Soils
- ASTM D3551-17 Standard Practice for Laboratory Preparation of Soil-Lime Mixtures Using Mechanical Mixer
- ASTM D3552-17 Standard Test Method for Tensile Properties of Fiber Reinforced Metal Matrix Composites
- ASTM D3554-20e1 Standard Specification for Track-Resistant Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 °C Operation
- ASTM D3556-23 Standard Guide for Deposition on Glassware During Mechanical Dishwashing
- ASTM D3557-17 Standard Test Methods for Cadmium in Water
- ASTM D3561-16(2021)e1 Standard Test Method for Lithium, Potassium, and Sodium Ions in Brackish Water, Seawater, and Brines by Atomic Absorption Spectrophotometry