
【国外标准】 Standard Test Method for Normal Spectral Emittance at Elevated Temperatures
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The significant features are typified by a discussion of the limitations of the technique. With the description and arrangement given in the following portions of this test method, the instrument will record directly the normal spectral emittance of a specimen. However, the following conditions must be met within acceptable tolerance:5.1.1 The effective temperatures of the specimen and blackbody must be within 1 K of each other. Practical limitations arise, however, because the temperature uniformities are often not better than a few degrees Kelvin.5.1.2 The optical path length in the two beams must be equal, or the instrument should operate in a nonabsorbing atmosphere or a vacuum, in order to eliminate the effects of differential atmospheric absorption in the two beams. Measurements in air are in many cases important, and will not necessarily give the same results as in a vacuum, thus the equality of the optical paths for dual beam instruments becomes very critical.NOTE 3: Very careful optical alignment of the spectrophotometer is required to minimize differences in absorptance along the two paths of the instrument, and careful adjustment of the chopper timing to reduce “cross-talk” (the overlap of the reference and sample signals) as well as precautions to reduce stray radiation in the spectrometer are required to keep the zero line flat. With the best adjustment, the “100 % line” will be flat to within 3 %; both of these measurements should be reproducible within these limits (see 7.3, Note 6).5.1.3 Front-surface mirror optics must be used throughout, except for the prism in prism monochromators and the grating in grating monochromators, and it should be emphasized that equivalent optical elements must be used in the two beams in order to reduce and balance attenuation of the beams by absorption in the optical elements. It is recommended that optical surfaces be free of SiO2 and SiO coatings; MgF2 may be used to stabilize mirror surfaces for extended periods of time. The optical characteristics of these coatings are critical, but can be relaxed if all optical paths are fixed during measurements or the incident angles are not changed between modes of operation (during “0 % line,” “100 % line,” and sample measurements). It is recommended that all optical elements be adequately filled with energy.5.1.4 The source and field apertures of the two beams must be equal in order to ensure that radiant flux in the two beams compared by the apparatus will pertain to equal areas of the sources and equal solid angles of emission. In some cases it may be desirable to define the solid angle of the source and sample when comparing alternative measurement techniques.5.1.5 The response of the detector-amplifier system must vary linearly with the incident radiant flux.1.1 This test method describes a highly accurate technique for measuring the normal spectral emittance of electrically conducting materials or materials with electrically conducting substrates, in the temperature range from 600 to 1400 K, and at wavelengths from 1 to 35 μm.1.2 The test method requires expensive equipment and rather elaborate precautions, but produces data that are accurate to within a few percent. It is suitable for research laboratories where the highest precision and accuracy are desired, but is not recommended for routine production or acceptance testing. However, because of its high accuracy this test method can be used as a referee method to be applied to production and acceptance testing in cases of dispute.1.3 The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E307-72(2019)
标准名称:
Standard Test Method for Normal Spectral Emittance at Elevated Temperatures
英文名称:
Standard Test Method for Normal Spectral Emittance at Elevated Temperatures标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI X9.105 Part 3-2009 (R2019) Identical to ISO 8583-3:2008 Financial transaction card originated messages - Interchange message specifications - Part 3: Maintenance procedures for messages, data elements and code values
- ANSI X9.105-1:2009 (R2019) (Identical to ISO 8583-1:2009) Financial transaction card originated messages - Interchange message specifications -Part 1: Messages, data elements and code values
- ANSI X9.8-1-2019/ISO 9564-1-2017 Financial services - Personal Identification Number (PIN) management and security - Part 1: Basic principles and requirements for PINs in card-based systems (Identical Adoption)
- ANSI/OPEI B175.2-2012 (R2019) Outdoor Power Equipment - Internal Combustion Engine-Powered Handheld and Backpack Blowers and Blower-Vacuums - Safety Requirements and Performance Testing Procedures
- ANSI/OPEI B175.7-2019 Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Pole Mounted Pruners - Safety and Environmental Requirements
- AS 1141.72-1996 Methods for sampling and testing of aggregates Cement content of cement stabilized materials
- AS 1333-1994 (R2019)/Amdt 1-2000 Conveyor belting of elastomeric and steel cord construction
- AS 2300.6.5-1990 (R2019)/Amdt 1-1992 Methods of chemical and physical testing for the dairying industry - Cheese - Determination of salt
- AS 2300.6.5-1990 (R2019)/Amdt 2-1997 Methods of chemical and physical testing for the dairying industry - Cheese - Determination of salt
- AS 2805.6.1.1-2009 (R2019)/Amdt 1-2011 Electronic funds transfer - Requirements for interfaces Key management - Principles
- AS 3565.4-2007 (R2019)/Amdt 1-2010 Meters for water supply In-service compliance testing
- ASTM F2783-20 Standard Practice for Design, Manufacture, Operation, Maintenance, and Inspection of Amusement Rides and Devices, in Canada
- ASTM F2787-13(2018) Standard Practice for Structural Design of Thermoplastic Corrugated Wall Stormwater Collection Chambers
- ASTM F2789-10(2020) Standard Guide for Mechanical and Functional Characterization of Nucleus Devices
- ASTM F2790-10(2019)e1 Standard Practice for Static and Dynamic Characterization of Motion Preserving Lumbar Total Facet Prostheses