
【国外标准】 Standard Specification for Multilayer Pipe Type 2, Compression Fittings, and Compression Joints for Hydronic Heating Systems (Withdrawn 2020)
本网站 发布时间:
2024-02-28
- ASTM F1987-01(2011)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This specification covers requirements for multilayer pipe type 2 and compression fittings for hydronic heating systems. Multilayer Pipe Type is a construction-based pressure rated pipe comprising more than one layer in which at least 60 % of the wall thickness is polymeric material. Multilayer pipe type 2 is produced using a butt-welded aluminum pipe as a core, with an extruded inside layer of crosslinked polyethylene (PEX). An adhesive layer is used to bond the inside layer to the wall of the aluminum pipe. An outer layer of polyethylene (PE) and an adhesive layer are extruded to the outer wall of the aluminum pipe. Materials shall be tested and shall conform to specified values of multilayer pipe configurations 1 and 2, compression fittings for multilayer pipe, O-rings, multilayer pipe dimensions, compression fitting dimensions, minimum burst pressure, sustained pressure, thermal cycling test, and excessive temperature/pressure capability. Among the test methods included are: sustained-hydrostatic-pressure test, thermal cycling test, water hammer test, delamination, fusion line test, and excessive temperature/pressure capability test.1.1 This specification covers requirements for multilayer pipe type 2 and compression fittings for hydronic heating systems, with a maximum pressure/temperature range of 1000 kPa (145 psi), at 82°C (180°F).Note 1—Multilayer Pipe Type 2Construction-based pressure rated pipe comprising more than one layer in which at least 60 % of the wall thickness is polymeric material.1.2 Multilayer pipe type 2 is produced using a butt-welded aluminum pipe as a core, with an extruded inside layer of crosslinked polyethylene (PEX). An adhesive layer is used to bond the inside layer to the wall of the aluminum pipe. An outer layer of polyethylene (PE) and an adhesive layer are extruded to the outer wall of the aluminum pipe.1.3 Multilayer pipe type 2 is produced in Configurations 1 and 2, as shown in Fig. 1.1.4 This specification includes compression fittings, which are referenced in Fig. 2.1.5 Specifications for threaded or solder adapters for use with pipe and fittings meeting the requirements of this specification are given in Annex A1 and Annex A2.1.6 The following safety hazards caveat pertains only to the test method portion of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.7 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in nonconformance with this specification.
标准号:
ASTM F1987-01(2011)
标准名称:
Standard Specification for Multilayer Pipe Type 2, Compression Fittings, and Compression Joints for Hydronic Heating Systems (Withdrawn 2020)
英文名称:
Standard Specification for Multilayer Pipe Type 2, Compression Fittings, and Compression Joints for Hydronic Heating Systems (Withdrawn 2020)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM F1986-01(2011) Standard Specification for Multilayer Pipe Type 2, Compression Fittings, and Compression Joints for Hot and Cold Drinking-Water Systems (Withdrawn 2020)
- 下一篇: ASTM F1988-99(2020) Standard Performance Requirements for Plastic Chaise Lounges, With or Without Moving Arms, With Adjustable Backs, for Outdoor Use
- 推荐标准
- ANSI/INCITS/ISO/IEC TR 11581-1:2011[2015] Information technology - User interface icons - Part 1: Introduction to and overview of icon standards
- ANSI/INCITS/ISO/IEC TR 19075-1:2011[2015] Information technology - Database languages - SQL Technical Reports - Part 1: XQuery Regular Expression Support in SQL
- AS 1012.10-1985/Amdt 1-1987 Methods of testing concrete - Method for the determination of indirect tensile strength of concrete cylinders ('Brazil' or splitting test)
- AS 1088.0-1987 Hearing aids Measurement of electroacoustical characteristics
- AS 1088.1-1987 Hearing aids Hearing aids with induction pick-up coil input
- AS 1088.3-1987 Hearing aids Hearing aid equipment not entirely worn on the listener
- AS 1088.4-1987 Hearing aids Magnetic field strength in audio-frequency induction loops for hearing aid purposes
- AS 1088.6-1987 Hearing aids Characteristics of electrical input circuits for hearing aids
- AS 1088.7-1987 Hearing aids Measurement of the performance characteristics of hearing aids for quality inspection for delivery purposes
- AS 1088.8-1987 Hearing aids Method of measurement of performance characteristic of hearing aids under simulated in situ working conditions
- AS 1101.3-1987 Graphical symbols for general engineering Welding and non-destructive examination
- AS 1158.1-1986/Amdt 1-1987 The lighting of urban roads and other public thoroughfares - Performance and installation design requirements
- AS 1158.4-1987 The lighting of urban roads and other public thoroughfares Supplementary lighting at pedestrian crossings
- AS 1288-2006 (R2016)/Amdt 2-2011 Glass in buildings - Selection and installation
- AS 1311-1987 Steel tendons for prestressed concrete-7-wire stress-relieved steel strand for tendons in prestressed concrete