
【国外标准】 Standard Practice for Testing Electrolytic Conductivity Detectors (ELCD) Used in Gas Chromatography
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
3.1 Although it is possible to observe and measure each of the several characteristics of the ELCD under different and unique conditions, in particular its different modes of selectivity, it is the intent of this practice that a complete set of detector specifications should be obtained at the same operating conditions, including geometry, gas and solvent flow rates, and temperatures. It should be noted that to specify a detector's capability completely, its performance should be measured at several sets of conditions within the useful range of the detector. The terms and tests described in this practice are sufficiently general so that they may be used at whatever conditions may be chosen for other reasons.3.2 Linearity and speed of response of the recorder used should be such that it does not distort or otherwise interfere with the performance of the detector. Effective recorder response should be sufficiently fast so that it can be neglected in sensitivity of measurements. If additional amplifiers are used between the detector and the final readout device, their characteristics should also first be established.1.1 This practice covers testing the performance of an electrolytic conductivity detector (ELCD) used as the detection component of a gas chromatographic system.1.2 This practice is directly applicable to electrolytic conductivity detectors that perform a chemical reaction on a given sample over a nickel catalyst surface under oxidizing or reducing conditions and employ a scrubber, if needed, to remove interferences, deionized solvent to dissolve the reaction products, and a conductivity cell to measure the electrolytic conductivity of ionized reaction products.1.3 This practice covers the performance of the detector itself, independently of the chromatographic column, in terms that the analyst can use to predict overall system performance when the detector is coupled to the column and other chromatographic system components.1.4 For general gas chromatographic procedures, Practice E260 should be followed except where specific changes are recommended herein for the use of an electrolytic conductivity detector. For definitions of gas chromatography and its various terms see Practice E355.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E1698-95(2017)
标准名称:
Standard Practice for Testing Electrolytic Conductivity Detectors (ELCD) Used in Gas Chromatography
英文名称:
Standard Practice for Testing Electrolytic Conductivity Detectors (ELCD) Used in Gas Chromatography标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- INCITS 11-1990 (S2017) General Purpose Paper Cards for Information Processing
- INCITS 111-1986 (S2017) Information Systems - Optical Character Recognition (OCR) - Matrix Character Sets for OCR-M
- INCITS 115-1984 (S2017) Unformatted 80 Megabyte Trident Pack for Use at 370 TPI and 6000 BPI - Physical, Mechanical and Magnetic Characteristics
- INCITS 116-1986 (S2017) Recorded Magnetic Tape Cartridge for Information Interchange 4-Track, Serial 0.250 in (6.30 mm) 6400 BPI (252 BPMM) Inverted Modified Frequency Modulation Encoded
- INCITS 117-1984 (S2017) Printable/Image Areas for Text and Facsimile Communication Equipment
- INCITS 119-1984 (S2017) Contact Start/Stop Storage Disk, 158361 Flux Transitions per Track, 8.268 Inch (210 mm) Outer Diameter and 3.937 Inch (100 mm) Inner Diameter
- INCITS 120-1984 (S2017) Contact Start/Stop Storage Disk, 95840 Flux Transitions per Track, 7.874 Inch (200 mm) Outer Diameter and 2.500 Inch (63.5 mm) Inner Diameter
- INCITS 126-1986 (S2017) One- and Two-Sided Double Density Unformatted 5.25 Inch (130 mm) 96 Tracks per Inch (3.8 Tracks per mm) Flexible Disk Cartridge - General, Physical, and Magnetic Requirements for 7958 BPR Use
- INCITS 149-1986 (R2017) Financial Transaction Card Formsets - Location of Imprinted Information
- INCITS 150-1987 (S2017) Business Machines, Data Processing Equipment and Business Forms - Character and Line Spacing
- INCITS 151-1987 (S2017) Bond Papers and Index Bristols - Common Sheet Sizes
- INCITS 152-1987 (S2017) Specifications for Noncarbonized, Single-Ply, Adding Machine Paper Rolls
- INCITS 163-1988 (S2017) Information Systems - Contact Start/Stop Metallic Film Storage Disk - 83,333 Flux Transitions Per Track, 130-mm (5.118-in) Outer Diameter and 40-mm (1.575-in) Inner Diameter
- INCITS 179-1990 (S2017) 95-mm Diameter Rigid Digital Recording Disk
- INCITS 182-1990 (S2017) Guideline for Bar Code Print Quality