
【国外标准】 Standard Test Method for Determining the Antimicrobial Activity of Antimicrobial Agents Under Dynamic Contact Conditions
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Substrate–bonded, antimicrobial agents are not typically free to diffuse into their environment under normal conditions of use. This test method ensures good contact between the bacteria and the treated fiber, fabric, or other substrate, by constant agitation of the test specimen in a challenge suspension during the test period.5.2 The metabolic state of the challenge species can directly affect measurements of the effectiveness of particular antimicrobial agents or concentrations of agents. The susceptibility of the species to particular biocides could be altered depending on its life stage (cycle). One-hour contact time in a buffer solution allows for metabolic stasis in the population. This test method standardizes both the growth conditions of the challenge species and substrate contact times to reduce the variability associated with growth phase of the microorganism.5.3 Leaching of an antimicrobial is dependent upon the test conditions being utilized and the ultimate end use of the product. Additional testing may be required to determine if a compound is substrate-bound in all conditions or during the end use of the product.5.4 This test method cannot determine if a compound is leaching into solution or is immobilized on the substrate. This test method is only intended to determine efficacy as described in subsequent portions of the method.5.5 The test is suitable for evaluating stressed or modified specimens, when accompanied by adequate controls.NOTE 1: Stresses may include laundry, wear and abrasion, radiation and steam sterilization, UV exposure, solvent manipulation, temperature susceptibility, or similar physical or chemical manipulation.1.1 This test method is designed to evaluate the antimicrobial activity of antimicrobial-treated specimens under dynamic contact conditions. This dynamic shake flask test was developed for routine quality control and screening tests in order to overcome difficulties in using classical antimicrobial test methods to evaluate substrate-bound antimicrobials. These difficulties include ensuring contact of inoculum to treated surface (as in AATCC TM100), flexibility of retrieval at different contact times, use of inappropriately applied static conditions (as in AATCC TM147), sensitivity, and reproducibility.1.2 This test method allows for the ability to evaluate many different types of treated substrates and a wide range of microorganisms. Treated substrates used in this test method can be subjected to a wide variety of physical/chemical stresses or manipulations and allows for the versatility of testing the effect of contamination due to such things as hard water, proteins, blood, serum, various chemicals, and other contaminants.1.3 Surface antimicrobial activity is determined by comparing results from the test sample to controls run simultaneously.1.4 This test method may not be appropriate for all types of antimicrobial-treated articles or antimicrobial agents. The proper test methodology should be determined based on antimicrobial mode of action and end-use expectations (Guide E2922)1.5 Proper neutralization of all antimicrobials must be confirmed using Test Methods E1054.1.6 This test method should be performed only by those trained in microbiological techniques.1.7 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.8 This standard may involve hazardous materials, operations and equipment. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2149-20
标准名称:
Standard Test Method for Determining the Antimicrobial Activity of Antimicrobial Agents Under Dynamic Contact Conditions
英文名称:
Standard Test Method for Determining the Antimicrobial Activity of Antimicrobial Agents Under Dynamic Contact Conditions标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 60695.11.20:2001/Amdt 1:2004 Fire hazard testing Test flames - 500 W flame test methods
- AS/NZS 60745.2.20:2003 Hand-held motor-operated electric tools - Safety - Particular requirements for band saws
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
- ASTM A1-00(2018) Standard Specification for Carbon Steel Tee Rails
- ASTM A1000/A1000M-17(2023) Standard Specification for Steel Wire, Carbon and Alloy Specialty Spring Quality
- ASTM A1001-18 Standard Specification for High-Strength Steel Castings in Heavy Sections
- ASTM A1002-16(2020) Standard Specification for Castings, Nickel-Aluminum Ordered Alloy
- ASTM A1004/A1004M-99(2018) Standard Practice for Establishing Conformance to the Minimum Expected Corrosion Characteristics of Metallic, Painted-Metallic, and Nonmetallic-Coated Steel Sheet Intended for Use as Cold Formed Framing Members
- ASTM A1009-18 Standard Specification for Soft Magnetic MnZn Ferrite Core Materials for Transformer and Inductor Applications
- ASTM A101-04(2019) Standard Specification for Ferrochromium
- ASTM A1010/A1010M-13(2018) Standard Specification for Higher-Strength Martensitic Stainless Steel Plate, Sheet, and Strip
- ASTM A1012-10(2021) Standard Specification for Seamless and Welded Ferritic, Austenitic and Duplex Alloy Steel Condenser and Heat Exchanger Tubes With Integral Fins
- ASTM A1015-01(2018) Standard Guide for Videoborescoping of Tubular Products for Sanitary Applications
- ASTM A1016/A1016M-23 Standard Specification for General Requirements for Ferritic Alloy Steel, Austenitic Alloy Steel, and Stainless Steel Tubes