【国外标准】 Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This test method provides a procedure for identification of those finished textile floor covering materials that can be rated as flame-resistant under specific controlled laboratory conditions.5.2 This test method does not specify the use of an underlay material. If an underlay material is used to assess the effect of a specific underlay in combination with a specific floor covering, such a variation in procedure must be noted in the report.5.3 In this test, results are observed with the specimens in a horizontal plane. Different results are possible if the same material is tested or used in any other plane.5.4 Test Method D2859 for testing finished textile floor covering materials for flammability is considered satisfactory for acceptance testing of commercial shipments since the method has been used extensively in the trade for acceptance testing. In cases of disagreement arising from differences in values reported by the purchaser and the seller when using this method for acceptance testing, the statistical bias, if any, between the laboratory of the purchaser and the laboratory of the seller shall be determined with each comparison being based on testing specimens randomly drawn from one sample of material of the type being evaluated.5.5 The test procedures of this standard are similar but not identical to those contained in the standards for the surface flammability of carpets and rugs of the U.S. Consumer Product Safety Commission4 (see also 1.1). The acceptance criterion of these CPSC standards requires that at least seven out of eight individual specimens of a given carpet or rug have passed the test, that is, that the charred portion of a tested specimen shall not extend to within 25.4 mm (1.0 in.) of the edge of the hole in the flattening frame at any point.5.6 The acceptance criterion of this test method is consistent with that of CPSC standards (see Section 10).1.1 This fire-test-response standard describes a test method for the determination of the flammability of finished textile floor covering materials when exposed to an ignition source under controlled laboratory conditions.1.1.1 Carpets and rugs offered for sale in the United States are required by the Consumer Product Safety Commission (CPSC) to comply with the test methods in 16 CFR 1630 or 16 CFR 1631, as appropriate.1.1.2 This test method is similar but not identical to the test methods contained in 16 CFR 1630 and CFR 1631 and issued by CPSC. If compliance with one of the CPSC test methods is required, this test method does not ensure regulatory compliance.1.2 This test method is applicable to all types of textile floor coverings, regardless of the method of fabrication or whether they are made from natural or man-made fibers. It is possible to apply this test method to unfinished material; however, the results of such a test shall not be considered a satisfactory evaluation of a textile floor covering material for ultimate consumer use.1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are provided for information only and are not considered standard.1.4 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions, but does not by itself incorporate all factors required for fire hazard or fire risk assessment of the materials, products, or assemblies under actual fire conditions.1.5 Fire testing of products and materials is inherently hazardous, and adequate safeguards for personnel and property shall be employed in conducting these tests1.6 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D2859-16(2021)
标准名称:
Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials
英文名称:
Standard Test Method for Ignition Characteristics of Finished Textile Floor Covering Materials标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 2350.16:2006 (R2016)/Amdt 1:2008 Methods of testing portland, blended and masonry cements Determination of air content of masonry cement
- AS/NZS 3350.2.16:1996/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements - Food waste disposers (IEC 60335-2-15:1994, MOD)
- AS/NZS 3580.16:2014 Methods for sampling and analysis of ambient air Determination of polycyclic aromatic hydrocarbons (PAH)
- AS/NZS 3750.16:1998 (R2013) Paints for steel structures Waterborne primer and paint for galvanized, zinc/aluminium alloy-coated and zinc-primed steel
- AS/NZS 3905.16:1998 Quality system guidelines Guidelines to quality in project management
- AS/NZS 4387.16:1996 Domestic kitchen assemblies - Methods of test Determination of calibration of drawer slamming apparatus
- AS/NZS 4524.16:1998 Bonded abrasive products - Dimensions Grinding wheels for cutting-off on an angle grinder
- AS/NZS 61000.4.16:2002/Amdt 1:2012 Electromagnetic compatibility (EMC) Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
- AS/NZS 61558.2.16:2010 (IEC TEXT)/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS 61558.2.16:2010/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS CISPR 16.1.1:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.1:2006 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.2:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances
- AS/NZS CISPR 16.1.3:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Disturbance power
- AS/NZS CISPR 16.1.4:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Radiated disturbances