
【国外标准】 Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This specification covers the requirements for seamless UNS C10200, C12000, or C12200 copper alloy tubes used for connection, repairs, or alternations of field air conditioning or refrigeration units. Materials in the form of billets, bars, or tubes should be used to produce a homogeneous uniform wrought structure by either hot or cold working. Each tube should be cold drawn to the finished size and wall thickness. Coiled lengths with soft annealed tempers should be bright annealed after coiling then dehydrated and either capped, plugged, crimped, or otherwise closed at both ends. Straight lengths with hard drawn tempers should be cleaned and either capped, plugged, or otherwise closed at both ends. The grain sizes, tensile properties, and eddy-current and cleanness test results should conform to the values listed herein.1.1 This specification covers the requirements for seamless copper tube intended for use in the connection, repairs, or alternations of air conditioning or refrigeration units in the field.NOTE 1: Fittings used for soldered or brazed connections in air conditioning and refrigeration systems are described in ASME Standard B16.22.NOTE 2: The assembly of copper tubular systems by soldering is described in Practice B828.NOTE 3: Solders for joining copper tubular systems are described in Specification B32. The requirements for acceptable fluxes for these systems are described in Specification B813.1.2 The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified:CopperUNS No. Previously UsedDesignation Description C10200 OF Oxygen free without residual deoxidantsC12000 DLP Phosphorus deoxidized, low residual phosphorusC12200 DHP Phosphorus deoxidized, high residual phosphorus1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.1.4 The following hazard statement pertains only to the test method described in 18.2.4 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM B280-23
标准名称:
Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service
英文名称:
Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI/OPEI B175.2-2012 (R2019) Outdoor Power Equipment - Internal Combustion Engine-Powered Handheld and Backpack Blowers and Blower-Vacuums - Safety Requirements and Performance Testing Procedures
- ANSI/OPEI B175.6-2018 Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Hedge Trimmers - Safety and Environmental Requirements
- ANSI/OPEI B175.7-2019 Outdoor Power Equipment - Internal Combustion Engine-Powered Hand-Held Pole Mounted Pruners - Safety and Environmental Requirements
- AS 1038.23-2002 (R2013) Coal and coke - Analysis and testing Higher rank coal and coke - Carbonate carbon
- AS 1774.23.1-1992 Refractories and refractory materials - Physical test methods Abradability index - Oblique method
- AS 1807.23-1989 Cleanrooms, workstations and safety cabinets - Methods of test Determination of intensity of radiation from germicidal ultraviolet lamps
- AS 2545/B-1987 (Reference Use Only) Subcontract conditions - Annexure to AS 2545 including certificate of substantial completion form of formal instrument of agreement
- AS 2545/B-1993 (Reference Use Only) Subcontract conditions (AS 2545-1993) - Annexure Part B
- ASTM F2783-20 Standard Practice for Design, Manufacture, Operation, Maintenance, and Inspection of Amusement Rides and Devices, in Canada
- ASTM F2787-13(2018) Standard Practice for Structural Design of Thermoplastic Corrugated Wall Stormwater Collection Chambers
- ASTM F2789-10(2020) Standard Guide for Mechanical and Functional Characterization of Nucleus Devices
- ASTM F2790-10(2019)e1 Standard Practice for Static and Dynamic Characterization of Motion Preserving Lumbar Total Facet Prostheses
- ASTM F2791-24 Standard Guide for Assessment of Surface Texture of Non-Porous Biomaterials in Two Dimensions
- ASTM F2793-14(2023) Standard Specification for Bicycle Grips
- ASTM F2795-18 Standard Test Method for Performance of Self-Contained Soft Serve and Shake Freezers