【国外标准】 Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate/Metallic Coatings
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The shear and bending fatigue tests are used to determine the effect of variations in material, geometry, surface condition, stress, and so forth, on the fatigue resistance of coated metallic materials subjected to direct stress for up to 107 cycles. These tests may be used as a relative guide to the selection of coated materials for service under condition of repeated stress.5.2 In order that such basic fatigue data be comparable, reproducible, and can be correlated among laboratories, it is essential that uniform fatigue practices be established.5.3 The results of the fatigue test may be used for basic material property design. Actual components should not be tested using these test methods.1.1 This test method covers the procedure for determining the shear and bending fatigue performance of calcium phosphate coatings and of porous and nonporous metallic coatings and for determining the bending fatigue performance of metallic coatings over sprayed with calcium phosphate. This test method has been established based on plasma-sprayed titanium and plasma-sprayed hydroxylapatite coatings. The efficacy of this test method for other coatings has not been established. In the shear fatigue mode, this test method evaluates the adhesive and cohesive properties of the coating on a metallic substrate. In the bending fatigue mode, this test method evaluates both the adhesion of the coating as well as the effects that the coating may have on the substrate material. These methods are limited to testing in air at ambient temperature. These test methods are not intended for application in fatigue tests of components or devices; however, the test method which most closely replicates the actual loading configuration is preferred.1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F1160-14(2017)e1
标准名称:
Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate/Metallic Coatings
英文名称:
Standard Test Method for Shear and Bending Fatigue Testing of Calcium Phosphate and Metallic Medical and Composite Calcium Phosphate/Metallic Coatings标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- INCITS 11-1990 (S2017) General Purpose Paper Cards for Information Processing
- INCITS 111-1986 (S2017) Information Systems - Optical Character Recognition (OCR) - Matrix Character Sets for OCR-M
- INCITS 115-1984 (S2017) Unformatted 80 Megabyte Trident Pack for Use at 370 TPI and 6000 BPI - Physical, Mechanical and Magnetic Characteristics
- INCITS 116-1986 (S2017) Recorded Magnetic Tape Cartridge for Information Interchange 4-Track, Serial 0.250 in (6.30 mm) 6400 BPI (252 BPMM) Inverted Modified Frequency Modulation Encoded
- INCITS 117-1984 (S2017) Printable/Image Areas for Text and Facsimile Communication Equipment
- INCITS 119-1984 (S2017) Contact Start/Stop Storage Disk, 158361 Flux Transitions per Track, 8.268 Inch (210 mm) Outer Diameter and 3.937 Inch (100 mm) Inner Diameter
- INCITS 120-1984 (S2017) Contact Start/Stop Storage Disk, 95840 Flux Transitions per Track, 7.874 Inch (200 mm) Outer Diameter and 2.500 Inch (63.5 mm) Inner Diameter
- INCITS 126-1986 (S2017) One- and Two-Sided Double Density Unformatted 5.25 Inch (130 mm) 96 Tracks per Inch (3.8 Tracks per mm) Flexible Disk Cartridge - General, Physical, and Magnetic Requirements for 7958 BPR Use
- INCITS 14-1983[S2011] Recorded Magnetic Tape for Information Interchange (200 CPI, NRZI) (formerly ANSI X3.14-1983 (R2001))
- INCITS 149-1986 (R2017) Financial Transaction Card Formsets - Location of Imprinted Information
- INCITS 150-1987 (S2017) Business Machines, Data Processing Equipment and Business Forms - Character and Line Spacing
- INCITS 151-1987 (S2017) Bond Papers and Index Bristols - Common Sheet Sizes
- INCITS 152-1987 (S2017) Specifications for Noncarbonized, Single-Ply, Adding Machine Paper Rolls
- INCITS 163-1988 (S2017) Information Systems - Contact Start/Stop Metallic Film Storage Disk - 83,333 Flux Transitions Per Track, 130-mm (5.118-in) Outer Diameter and 40-mm (1.575-in) Inner Diameter
- INCITS 179-1990 (S2017) 95-mm Diameter Rigid Digital Recording Disk