
【国外标准】 Standard Test Method for Limit of Detection of Fluorescence of Quinine Sulfate in Solution
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 When determining the limiting detectable concentration of a fluorescent substance, it is usually necessary to increase the readout scale of a photoelectric instrument to a point where noise (that is, random fluctuations of the system) becomes apparent. This noise will be superimposed upon the signal from the sample.4.2 In molecular fluorescence spectroscopy, the limit of detection for the sample will be determined by the limiting signal-to-noise ratio, S/N, where the signal, S, is the difference between readings obtained with the sample and blank solutions, and N is the total root-mean-square (rms) noise. The limit of detection for the sample will be given by the instrument readings that give a signal equal to three times the rms value of the noise.NOTE 2: Factors other than noise affecting the sample concentration corresponding to the limit of detection include: the spectral bandwidths of the excitation and emission monochromators, the intensity of the exciting light that can be concentrated on the sample, the fraction of the fluorescence collected by the detection system, the response time of the detection system, and the purity of the solvent. The size and arrangement of the sample container with respect to the light beams are also important, as they affect both the desired signal and the extraneous signal that only contributes noise.NOTE 3: The value of rms noise (N) can be obtained by calculating the standard deviation of a series of readings of the signal from the sample at the peak emission wavelength at approximately 450 nm as follows:where: = mean of the series of readings,x = value of the individual reading, andn = number of readings.Alternatively, rms noise may be estimated by noting the extreme differences between the members of a series of readings (peak-to-peak noise) and dividing by a factor that is usually taken to be 5.6, 71.1 This test method employs the signal-to-noise ratio to determine the sensitivity of a fluorescence measuring system in testing for the limit of detection (LOD) of quinine sulfate dihydrate in solution. The results obtained with quinine sulfate dihydrate in solution are suitable for specifying instrument performance on samples having excitation and fluorescence bands wider than 10 nm at or near room temperature.1.1.1 This test method is not intended to be used as (1) a rigorous test of performance of instrumentation, or (2), to intercompare the quantitative performance of instruments of different design. Intercomparison of the LOD between instruments is commonly expressed as the ratio of the water Raman peak intensity to the root-mean-square (rms) noise as measured on a fluorometer using an excitation wavelength of 350 nm This test method uses the excitation and emission peak wavelengths for quinine sulfate dihydrate in solution, which are approximately 350 nm and 450 nm, respectively.1.2 This test method has been applied to fluorescence-measuring systems utilizing non-laser, low-energy excitation sources. There is no assurance that extremely intense illumination will not cause photodecomposition2 of the compound suggested in this test method. For this reason, it is recommended that this test method not be indiscriminately employed with high intensity light sources. This test method is not intended to determine minimum detectable amounts of other materials. If this test method is extended to employ other chemical substances, the user should be aware of the possibility that these other substances may undergo decomposition or adsorption onto containers.1.3 A typical LOD for conventional fluorometers using this test method is 1 ng of quinine sulfate per mL.1.4 The suggested shelf life of a 1 mg/mL stock solution of quinine sulfate dihydrate is three months, when stored in the dark in a stoppered glass bottle.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E579-04(2023)
标准名称:
Standard Test Method for Limit of Detection of Fluorescence of Quinine Sulfate in Solution
英文名称:
Standard Test Method for Limit of Detection of Fluorescence of Quinine Sulfate in Solution标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ANSI X9.104-1-2004 (R2023) Financial transaction card originated messages - Card acceptor to acquiring host messages - Part 1: Messages, data elements and code values
- ANSI X9.104-2-2004 (R2023) Financial transaction card originated messages - Card acceptor to acquiring host messages - Part 2: Convenience store and petroleum marketing industry
- ASTM D4882-17 Standard Test Method for Bond Strength of Electrical Insulating Varnishes by the Twisted-Coil Test
- ASTM D4883-18 Standard Test Method for Density of Polyethylene by the Ultrasound Technique
- ASTM D4886-23 Standard Test Method for Abrasion Resistance of Geotextiles (Sandpaper/Sliding Block Method)
- ASTM D4887/D4887M-11(2021)e1 Standard Practice for Preparation of Viscosity Blends for Hot Recycled Asphalt Materials
- ASTM D4889-21 Standard Test Methods for Polyurethane Raw Materials: Determination of Viscosity of Crude or Modified Isocyanates
- ASTM D4891-13(2018) Standard Test Method for Heating Value of Gases in Natural Gas and Flare Gases Range by Stoichiometric Combustion
- ASTM D4894-19 Standard Specification for Polytetrafluoroethylene (PTFE) Granular Molding and Ram Extrusion Materials
- ASTM D4895-18(2023) Standard Specification for Polytetrafluoroethylene (PTFE) Resin Produced From Dispersion
- ASTM D4897/D4897M-16(2023) Standard Specification for Asphalt-Coated Glass-Fiber Venting Base Sheet Used in Roofing
- ASTM D4898-23 Standard Test Method for Insoluble Contamination of Hydraulic Fluids by Gravimetric Analysis
- ASTM D4899-99(2020) Standard Practice for Analysis of Vegetable Tanning Materials—General
- ASTM D4902-99(2020) Standard Test Method for Evaporation and Drying of Analytical Solutions
- ASTM D4903-99(2020) Standard Test Method for Total Solids and Water in Vegetable Tanning Material Extracts