
【国外标准】 Standard Test Method for Isolation and Enumeration of Enterococci from Water by the Membrane Filter Procedure
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The enterococci are indicators of the bacteriological quality for potable water, shellfish growing waters, ambient, and recreational waters. A direct relationship between swimming, associated gastroenteritis, and enterococci has been established through epidemiological studies and marine and fresh water bathing beaches. These studies have led to the development of criteria that can be used to establish bathing water standards based on established health-water quality relationships.5.2 Since small or large volumes of water or dilutions thereof, can be analyzed by the membrane filter technique, a wide range of levels of enterococci in water can be enumerated and detected.1.1 This test method covers a membrane filter (MF) procedure for the detection and enumeration of the enterococci bacteria in water. The enterococci, which include Entero-coccus faecalis (E. faecalis), E. faecium, and their varieties are commonly found in the feces of humans and other warm-blooded animals. Although some strains are ubiquitous and not related to fecal pollution, enterococci in water are an indication of fecal pollution and the possible presence of enteric pathogens. These bacteria are found in water and wastewater in a wide range of densities. The detection limit is one colony forming unit (CFU)/volume filtered.1.2 This test method has been used successfully with temperate fresh and marine ambient waters, and wastewaters. It is the user’s responsibility to ensure the validity of this test method for waters of untested types.1.3 The values stated in SI units are to be regarded as standard. The values given in parentheses after SI units are included for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 9.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D5259-19
标准名称:
Standard Test Method for Isolation and Enumeration of Enterococci from Water by the Membrane Filter Procedure
英文名称:
Standard Test Method for Isolation and Enumeration of Enterococci from Water by the Membrane Filter Procedure标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM D5258-22 Standard Practice for Acid-Extraction of Elements from Sediments Using Closed Vessel Microwave Heating
- 下一篇: ASTM D5260-22 Standard Classification for Chemical Resistance of Poly(Vinyl Chloride) (PVC) Homopolymer and Copolymer Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds
- 推荐标准
- AS 1012.19-1988 Methods of testing concrete Accelerated curing of concrete compression test specimens (laboratory or field) - Hot water and warm water methods
- AS 1418.19-2007 Cranes, hoists and winches Telescopic handlers
- AS 2001.7.19-1990 Methods of test for textiles Quantitative analysis of fibre mixtures - Binary mixtures of chlorofibres (homopolymers of vinyl chloride) and certain other fibres (method using concentrated sulfuric acid)
- AS 2359.19-2008 Powered industrial trucks Additional stability tests for industrial variable-reach trucks handling freight containers of length 6 m and above
- ASTM D3550/D3550M-17 Standard Practice for Thick Wall, Ring-Lined, Split Barrel, Drive Sampling of Soils
- ASTM D3551-17 Standard Practice for Laboratory Preparation of Soil-Lime Mixtures Using Mechanical Mixer
- ASTM D3552-17 Standard Test Method for Tensile Properties of Fiber Reinforced Metal Matrix Composites
- ASTM D3554-20e1 Standard Specification for Track-Resistant Thermoplastic High-Density Polyethylene Insulation for Wire and Cable, 75 °C Operation
- ASTM D3556-23 Standard Guide for Deposition on Glassware During Mechanical Dishwashing
- ASTM D3557-17 Standard Test Methods for Cadmium in Water
- ASTM D3561-16(2021)e1 Standard Test Method for Lithium, Potassium, and Sodium Ions in Brackish Water, Seawater, and Brines by Atomic Absorption Spectrophotometry
- ASTM D3562-22 Standard Performance Specification for Woven Drycleanable Coat Fabrics
- ASTM D3564-22 Standard Practice for Application of Floor Polishes to Maintain Vinyl Composition Tile or Flooring
- ASTM D3574-17 Standard Test Methods for Flexible Cellular Materials—Slab, Bonded, and Molded Urethane Foams
- ASTM D3575-20 Standard Test Methods for Flexible Cellular Materials Made from Olefin Polymers