【国外标准】 Standard Practice for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
6.1 Test Method A is the most frequently used in leak testing components which are structurally capable of being evacuated to pressures of 0.1 Pa (approximately 10−3 torr). Testing of small components can be correlated to calibrated leaks, and the actual leak rate can be measured or acceptance can be based on a maximum allowable leak. For most production needs acceptance is based on acceptance of parts leaking less than an established standard which will ensure safe performance over the projected life of the component. Care must be exercised to ensure that large systems are calibrated with reference leak at a representative place on the test volume. Leak rates are determined by calculating the net gain or loss through a leak in the test part that would cause failure during the expected life of the device.6.2 Test Method B is used for testing vacuum systems either as a step in the final test of a new system or as a maintenance practice on equipment used for manufacturing, environmental test or for conditioning parts. As the volume tends to be large, a check of the response time as well as system sensitivity should be made. Volume of the system in liters divided by the speed of the vacuum pump in L/s will give the response time to reach 63 % of the total signal. Response times in excess of a few seconds makes leak detection difficult.6.3 Test Method C is to be used only when there is no convenient method of connecting the leak detector to the outlet of the high vacuum pump. If a helium leak detector is used and the high vacuum pump is an ion pump or cryopump, leak testing is best accomplished during the roughing cycle as these pumps leave a relatively high percentage of helium in the high vacuum chamber. This will obscure all but large leaks, and the trace gas will quickly saturate the pumps.1.1 This practice covers procedures for testing and locating the sources of gas leaking at the rate of 1 × 10 −8 Pa m3/s (1 × 10−9 Std cm 3/s)3 or greater. The test may be conducted on any object to be tested that can be evacuated and to the other side of which helium or other tracer gas may be applied.1.2 Three test methods are described:1.2.1 Test Method A—For the object under test capable of being evacuated, but having no inherent pumping capability.1.2.2 Test Method B—For the object under test with integral pumping capability.1.2.3 Test Method C—For the object under test as in Test Method B, in which the vacuum pumps of the object under test replace those normally used in the leak detector.1.3 Units—The values stated in either SI or std-cc/sec units are to be regarded separately as standard. The values stated in each system may not be exact equivalents: therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E498/E498M-11(2022)
标准名称:
Standard Practice for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode
英文名称:
Standard Practice for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- INCITS 11-1990 (S2017) General Purpose Paper Cards for Information Processing
- INCITS 124-1985 (S2022) Information processing systems - Computer graphics - Graphical Kernel System (GKS) Functional Description
- INCITS 199-1991 (S2022) Information Systems - 356-mm Optical Disk Cartridge (Write-Once) - Test Methods for Media Characteristics
- INCITS 207-1991 (S2022) Office Machines and Supplies - Alphanumeric Machines - Alternate Keyboard Arrangement
- INCITS 214-1992 (S2022) Information Systems - 130-mm Write-Once Optical Disk Cartridge Using Sampled Servo and 4/15 Encoding
- INCITS 222-1997 (S2022) Information technology - High-Performance Parallel Interface - Switch Control (HIPPI-SC)
- INCITS 259-1997 (S2022) Information Technology - FDDI Station Management-2 Packet Services (SMT-2-PS)
- INCITS 278-1997 (S2022) Information Technology - Fibre distributed data interface (FDDI) - Physical Layer Repeater Protocol (PHY-REP)
- INCITS 296-1997 (S2022) Information technology - Single Byte Command Code Sets CONnection (SBCON)
- INCITS 300-1997 (S2022) Information technology - High-Performance Parallel Interface - Serial Specification (HIPPI-Serial)
- INCITS 307-1997 (S2022) Information Technology - Serial Storage Architecture - Physical Layer 2 (SSA-PH2)
- INCITS 357-2002 (S2022) Information technology - Fibre Channel Virtual Interface Architecture Mapping Protocol (FC-VI)
- INCITS 358-2002/AM 1-2007 (R2022) Information technology - BioAPI Specification (Version 1.1) - Amendment 1: Support for Biometric Fusion
- INCITS 468-2010/AM1-2012 (R2022) Information technology - Multi-media Command Set - 6 (MMC-6) - Amendment 1
- INCITS 484-2012 (R2022) Information Technology SCSI Media Changer Commands - 3