
【国外标准】 Standard Test Method for Ethylene Oxide Content of Polyethoxylated Nonionic Surfactants
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
This test method covers the determination of ethylene oxide content in polyethoxylated nonionic surfactants. It can also be used for compounds containing propylene oxide or any compounds (glycols and glycol and polyglycol ethers and esters) which form unstable 1,2-diiodides on reaction with hydroiodic acid. The apparatus is comprised of the following: heat source which shall be an electric heater provided with a sliding rheostat or other means of heat control; flasks which shall be equipped with a standard ground-glass joint; condensers with standard joints; gas bubbler filled with dibutyl phthalate; buret; and pipet. The dual apparatus is designed to permit a sample and a blank to be run simultaneously. Reagent grade chemicals or reagents of sufficiently high purity including water, carbon dioxide or nitrogen, lubricant, dibutyl phthalate, glass beads, hydroiodic acid, hydrochloric acid, methanol, potassium dichromate, potassium iodide solution, sodium thiosulfate, and starch indicator solution shall be used in all tests. The ethylene oxide content shall be calculated from the amount of sodium thiosulfate solution required to titrate the sample and the blank, normality of sodium thiosulfate, and weight of the sample. Standard deviations for repeatability and reproducibility shall be estimated to determine the acceptability of the results.1.1 This test method covers the determination of ethylene oxide in polyethoxylated nonionic surfactants. It can also be used for compounds containing propylene oxide or any compounds (glycols and glycol and polyglycol ethers and esters) which form unstable 1,2-diiodides on reaction with hydriodic acid.NOTE 1: Compounds in which the oxyalkylene group is connected to a nitrogen cannot be entirely decomposed. This can be used to determine the percent of an ethoxylated surfactant in a mixture, if the ethylene oxide content of the ethoxylated surfactant is known.NOTE 2: This method reports results as percent ethylene oxide. If this method is applied to unknown compounds or compositions, the analyst should be aware of the possible presence of material other than ethylene oxide.NOTE 3: For use on built syndet compositions the organic active ingredient must be isolated in accordance with Test Method D2358.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Material Safety Data Sheets are available for reagents and materials. Review them for hazards prior to usage.
标准号:
ASTM D2959-95(2017)
标准名称:
Standard Test Method for Ethylene Oxide Content of Polyethoxylated Nonionic Surfactants
英文名称:
Standard Test Method for Ethylene Oxide Content of Polyethoxylated Nonionic Surfactants标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 1660.2.1:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application
- AS/NZS 1660.2.4:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to polyethylene and polypropylene materials
- AS/NZS 1660.2.5:1998 (R2017)/Amdt 1:2001 Test methods for electric cables, cords and conductors - Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to cables above 1 kV
- AS/NZS 3350.2.95:2000/Amdt 1:2001 Safety of household and similar electrical appliances Particular requirements - Drives for vertically moving garage doors for residential use
- AS/NZS 3808:2000 (R2017)/Amdt 2:2004 Insulating and sheathing materials for electric cables
- AS/NZS 4488.1:1997 (R2017)/Amdt 1:1999 Industrial rope access systems - Specifications
- AS/NZS 5065:2005 (R2017)/Amdt 1:2010 Polyethylene and polypropylene pipes and fittings for drainage and sewerage applications
- AS/NZS 60335.2.95:2005/Amdt 1:2009 Household and similar electrical appliances - Safety Particular requirements for drives for vertically moving garage doors for residential use
- ASTM 51026-23 Standard Practice for Using the Fricke Dosimetry System
- ASTM 52303-24 Standard Guide for Absorbed-Dose Mapping in Radiation Processing Facilities
- ASTM A1-00(2018) Standard Specification for Carbon Steel Tee Rails
- ASTM A1000/A1000M-17(2023) Standard Specification for Steel Wire, Carbon and Alloy Specialty Spring Quality
- ASTM A1001-18 Standard Specification for High-Strength Steel Castings in Heavy Sections
- ASTM A1002-16(2020) Standard Specification for Castings, Nickel-Aluminum Ordered Alloy
- ASTM A1004/A1004M-99(2018) Standard Practice for Establishing Conformance to the Minimum Expected Corrosion Characteristics of Metallic, Painted-Metallic, and Nonmetallic-Coated Steel Sheet Intended for Use as Cold Formed Framing Members