
【国外标准】 Standard Test Method for Separating an Ionizing Radiation-Induced MOSFET Threshold Voltage Shift Into Components Due to Oxide Trapped Holes and Interface States Using the Subthreshold Current–Voltage Characteristics (Withdrawn 2023)
本网站 发布时间:
2024-02-28
- ASTM F996-11(2018)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The electrical properties of gate and field oxides are altered by ionizing radiation. The method for determining the dose delivered by the source irradiation is discussed in Practices E666, E668, E1249, and Guide E1894. The time dependent and dose rate effects of the ionizing radiation can be determined by comparing pre- and post-irradiation voltage shifts, ΔVot and ΔVit. This test method provides a means for evaluation of the ionizing radiation response of MOSFETs and isolation parasitic MOSFETs.5.2 The measured voltage shifts, ΔVot and ΔVit, can provide a measure of the effectiveness of processing variations on the ionizing radiation response.5.3 This technique can be used to monitor the total-dose response of a process technology.1.1 This test method covers the use of the subthreshold charge separation technique for analysis of ionizing radiation degradation of a gate dielectric in a metal-oxide-semiconductor-field-effect transistor (MOSFET) and an isolation dielectric in a parasitic MOSFET.2,3,4 The subthreshold technique is used to separate the ionizing radiation-induced inversion voltage shift, ΔVINV into voltage shifts due to oxide trapped charge, ΔVot and interface traps, ΔV it. This technique uses the pre- and post-irradiation drain to source current versus gate voltage characteristics in the MOSFET subthreshold region.1.2 Procedures are given for measuring the MOSFET subthreshold current-voltage characteristics and for the calculation of results.1.3 The application of this test method requires the MOSFET to have a substrate (body) contact.1.4 Both pre- and post-irradiation MOSFET subthreshold source or drain curves must follow an exponential dependence on gate voltage for a minimum of two decades of current.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM F996-11(2018)
标准名称:
Standard Test Method for Separating an Ionizing Radiation-Induced MOSFET Threshold Voltage Shift Into Components Due to Oxide Trapped Holes and Interface States Using the Subthreshold Current–Voltage Characteristics (Withdrawn 2023)
英文名称:
Standard Test Method for Separating an Ionizing Radiation-Induced MOSFET Threshold Voltage Shift Into Components Due to Oxide Trapped Holes and Interface States Using the Subthreshold Current–Voltage Characteristics (Withdrawn 2023)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 1635.11.1:1995 Methods of test for pressure-sensitive adhesive tape - Water vapour transmission rate
- AS/NZS 2891.11:2014 Methods of sampling and testing asphalt Degree of particle coating
- AS/NZS 3200.2.11:1999 Medical electrical equipment Particular requirements for safety - Gamma beam therapy equipment
- AS/NZS 3350.2.11:1995/Amdt 1:1998 Approval and test specification - Safety of household and similar electrical appliances - Particular requirements - Tumbler dryers
- AS/NZS 3350.2.11:1999/Amdt 2:2001 Safety of household and similar electrical appliances - Particular requirements - Tumble dryers
- AS/NZS 3350.2.11:2001/Amdt 1:2007 Safety of household and similar electrical appliances Particular requirements for tumble dryers (IEC 60335-2-11:2000, MOD)
- AS/NZS 4456.11:1997 Masonry units and segmental pavers - Methods of test Determining coefficients of expansion
- AS/NZS 4456.11:2003/Amdt 1:2004 Masonry units, segmental pavers and flags - Methods of test Determining coefficients of expansion
- AS/NZS 60079.11:2000/Amdt 1:2001 Electrical apparatus for explosive gas atmospheres Intrinsic safety 'i'
- AS/NZS 60335.2.11:2002/Amdt 1:2004 Household and similar electrical appliances - Safety - Particular requirements for tumble dryers (IEC 60335-2-11 Ed 6, MOD)
- AS/NZS 60695.11.20:2001/Amdt 1:2004 Fire hazard testing Test flames - 500 W flame test methods
- AS/NZS 60695.11.3:2001 Fire hazard testing Test flames - 500 W flames - Apparatus and confirmational test methods (IEC 60695-11-3:2000, IDT)
- AS/NZS 60695.2.11:2001/Amdt 1:2001 Fire hazard testing Glowing/hot wire based test methods - Glow-wire flammability test method for end-products
- AS/NZS 60745.2.11:2003 Hand-held motor-operated electric tools - Safety - Particular requirements for reciprocating saws
- AS/NZS 60745.2.11:2009 Hand-held motor-operated electric tools - Safety Particular requirements for reciprocating saws (jig and sabre saws)