
【国外标准】 Standard Test Method for Group Types Quantification of Hydrocarbons in Hydrocarbon Liquids with a Boiling Point between 36 °C and 343 °C by Flow Modulated GCxGC – FID
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 Accurate quantitative compositional information on hydrocarbon types can be useful in determining the effects of processes in the production of various finished fuels. Producers may require additional determinations such as n-paraffins, i-paraffins, naphthenes, and aromatics for process optimization. This information also may be useful for indicating the quality of fuels and for assessing the relative combustion properties of finished fuels. This test method can be used to make such determinations.1.1 This test method covers the quantitative determination of total n-paraffins, total i-paraffins, total naphthenes (cycloparaffins), total one ring (1R) and total two ring plus (2R+) aromatic hydrocarbons in hydrocarbon liquids having a boiling point between 36 °C and 343 °C by GCxGC (flow modulated comprehensive two-dimensional gas chromatography). The method has been applied to aviation turbine fuels and is applicable to other low olefinic fuels in the stated boiling point range.1.2 This test method has an interim precision. An expanded full interlaboratory study is to be completed in <5 years. The test method working concentration ranges in mass percent for which the interim precision has been determined are as follows:Hydrocarbon Type Lower limit(mass percent) Upper limit(mass percent)Total i-paraffins 22.0 24.3Total n-paraffins 19.0 21.9Total naphthenes (cycloparaffins) 34.3 36.7Total one ring aromatics 18.7 21.8Total two ring plus aromatics 0.5 1.91.3 This test method is applicable to other group type concentration ranges, to other hydrocarbon types such as selected individual components, for example, benzene, toluene, or n-paraffins by carbon number, or to other hydrocarbon streams; however, precision has not been determined at this time. A future ILS will include a variety of sample types and extend the reporting.1.4 This test method is not intended to determine unsaturated hydrocarbons, such as olefins, content which may interfere with the cycloparaffins; this test method is applicable to samples with < 1% by mass total olefins as determined by D1319.1.5 This test method is not intended to determine FAME (fatty acid methyl esters). For such applications, Test Method D7797, IP 585, or equivalent test methods are available.1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.7 This standard test method does not mandate or describe a specific software package for data processing and display. Any commercially available GCxGC software used for data processing and display shall meet the requirements for the calculation of the results. Appendix X1 provides some guidelines.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM D8396-22
标准名称:
Standard Test Method for Group Types Quantification of Hydrocarbons in Hydrocarbon Liquids with a Boiling Point between 36 °C and 343 °C by Flow Modulated GCxGC – FID
英文名称:
Standard Test Method for Group Types Quantification of Hydrocarbons in Hydrocarbon Liquids with a Boiling Point between 36 °C and 343 °C by Flow Modulated GCxGC – FID标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- ASTM F3258-23 Standard Specification for Protectors for Rubber Insulating Gloves Meeting Specific Performance Requirements
- ASTM F3259-17 Standard Guide for Micro-computed Tomography of Tissue Engineered Scaffolds
- ASTM F3260-18 Standard Test Method for Determining the Flexural Stiffness of Medical Textiles
- ASTM F3262-17 Standard Classification System for Small Unmanned Aircraft Systems (sUASs) for Land Search and Rescue
- ASTM F3265-17(2023) Standard Test Method for Grid-Video Obstacle Measurement
- ASTM F3268-18a Standard Guide for in vitro Degradation Testing of Absorbable Metals
- ASTM F3270/F3270M-17 Standard Practice for Compression versus Load Properties of Gasket Materials
- ASTM F3273-17(2021)e1 Standard Specification for Wrought Molybdenum-47.5 Rhenium Alloy for Surgical Implants (UNS R03700)
- ASTM F3275-22 Standard Guide for Using a Force Tester to Evaluate Performance of a Brush Part Designed to Clean the Internal Channel of a Medical Device
- ASTM F3276-22 Standard Guide for Using a Force Tester to Evaluate the Performance of a Brush Part Designed to Clean the External Surface of a Medical Device
- ASTM F3277-19 Standard Specification for Cantilevered Steel Bunks Used in Detention and Correctional Facilities
- ASTM F3283/F3283M-18 Standard Specification for the Manufacturing of High-Voltage Proximity Alarm to be used for the Detection of Overhead High Voltage Alternating Current (AC)
- ASTM F3288/F3288M-20 Standard Specification for MRS-Rated Metric- and Inch-sized Crosslinked Polyethylene (PEX) Pressure Pipe
- ASTM F3292-19 Standard Practice for Inspection of Spinal Implants Undergoing Testing
- ASTM F3293-18 Standard Guide for Application of Test Soils for the Validation of Cleaning Methods for Reusable Medical Devices