
【国外标准】 Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 These practices should be used by a person who develops an analytical method to ensure that the spectral bandwidths cited in the practice are actually the ones used.NOTE 2: The method developer should establish the spectral bandwidths that can be used to obtain satisfactory results.4.2 These practices should be used to determine whether a spectral bandwidth specified in a method can be realized with a given spectrophotometer and thus whether the instrument is suitable for use in this application. If accurate absorbance measurements are to be made on compounds with sharp absorption bands (natural half band widths of less than 15 nm) the spectral bandwidth of the spectrometer used should be better than 1/8th of the natural half band width of the compound’s absorption.4.3 These practices allow the user of a spectrophotometer to estimate the actual spectral bandwidth of the instrument under a given set of conditions and to compare the result to the spectral bandwidth calculated from data given in the manufacturer's literature or indicated by the instrument.1.1 This practice describes procedures for estimating the spectral bandwidth of a spectrophotometer in the wavelength region of 185 nm to 820 nm.1.2 These practices are applicable to all modern spectrophotometer designs utilizing computer control and data handling. This includes conventional optical designs, where the sample is irradiated by monochromatic light, and ‘reverse’ optic designs coupled to photodiode arrays, where the light is separated by a polychromator after passing through the sample. For spectrophotometers that utilize servo-operated slits and maintain a constant period and a constant signal-to-noise ratio as the wavelength is automatically scanned, and/or utilize fixed slits and maintain a constant servo loop gain by automatically varying gain or dynode voltage, refer to the procedure described in Annex A1. This procedure is identical to that described in earlier versions of this practice.1.3 This practice does not cover the measurement of limiting spectral bandwidth, defined as the minimum spectral bandwidth achievable under optimum experimental conditions.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E958-13(2021)
标准名称:
Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers
英文名称:
Standard Practice for Estimation of the Spectral Bandwidth of Ultraviolet-Visible Spectrophotometers标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 2891.13.1:2013 Methods of sampling and testing asphalt Determination of the resilient modulus of asphalt - Indirect tensile method
- AS/NZS 3200.2.13:2005 Medical electrical equipment Particular requirements for safety - Anaesthetic systems
- AS/NZS 3350.2.13:1997/Amdt 3:2001 Safety of household and similar electrical appliances - Particular requirements - Deep fat fryers, frying pans and similar appliances
- AS/NZS 3350.2.13:2001/Amdt 1:2007 Safety of household and similar electrical appliances Particular requirements for deep fat fryers, frying pans and similar appliances (IEC 60335-2-13:1993, MOD)
- AS/NZS 3750.13:1997 (R2013) Paints for steel structures Epoxy primer (two pack)
- AS/NZS 3905.13:1998 Quality system guidelines Guide to AS/NZS ISO 9001:1994 for the food processing industry
- AS/NZS 4276.13:2008 Water microbiology Pseudomonas aeruginosa - Membrane filtration method
- AS/NZS 4456.13:1997 Masonry units and segmental pavers - Methods of test Determining pitting due to lime particles
- AS/NZS 4695.2.13:1996 Fire hazard testing electrotechnical products Test methods - Glow-wire ignitability test on materials
- AS/NZS 60335.2.13:2010 Household and similar electrical appliances - Safety Particular requirements for deep fat fryers, frying pans and similar appliances
- AS/NZS 60745.2.13:2010/Amdt 1:2011 Hand-held motor-operated electric Tools - Safety Particular requirements for chain saws
- AS/NZS 61000.4.13:2006 Electromagnetic compatibility (EMC) Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
- AS/NZS CISPR 13:2003 Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement
- ASC X9 TR 52-2021 Unsigned Items Including Remotely Created Checks (RCC) - Design and Usage Guide
- ASC X9 TR 54-2021 Blockchain Risk Assessment Framework