
【国外标准】 Standard Practice for Removal of Uranium or Plutonium, or both, for Impurity Assay in Uranium or Plutonium Materials
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This practice can be used to separate uranium or plutonium, or both, prior to the impurity analysis by various techniques. The removal of uranium and plutonium prior to quantification can improve the detection limits by minimizing the signal suppression caused by uranium or plutonium when using ICP techniques. Detection limits of ~1–10 part-per-billion (PPB) may be obtainable by matrix removal. Also, removal of the uranium and plutonium may allow the impurities analysis to be performed on a non-glove box enclosed instrument.5.2 Other test methods exist to determine impurities in uranium or plutonium. Test Method C1517 is able to determine many impurities in uranium at detection levels of ~1–10 part-per-million (ppm) by DC-Arc Spectrometry. Test Method C1287 is able to determine impurities in uranium at detection levels of ~100 ppb by ICP-MS. Test Method C1432 provides an alternative technique to remove plutonium by ion exchange prior to analysis of the impurities by ICP-AES.5.3 This practice can be used to demonstrate compliance with nuclear fuel specifications, for example, Specifications C753, C757, C776, C787, C788, and C996.1.1 This practice covers instructions for using an extraction chromatography column method for the removal of plutonium or uranium, or both, from liquid or digested oxides or metals prior to impurity measurements. Quantification of impurities can be made by techniques such as inductively coupled plasma mass spectrometry (ICP-MS), inductively coupled plasma atomic emission spectrometry (ICP-AES), or atomic absorption spectrometry (AAS.)1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM C1647-20
标准名称:
Standard Practice for Removal of Uranium or Plutonium, or both, for Impurity Assay in Uranium or Plutonium Materials
英文名称:
Standard Practice for Removal of Uranium or Plutonium, or both, for Impurity Assay in Uranium or Plutonium Materials标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM C1646/C1646M-16 Standard Practice for Making and Curing Test Specimens for Evaluating Resistance of Coarse Aggregate to Freezing and Thawing in Air-Entrained Concrete
- 下一篇: ASTM C1648-12(2023) Standard Guide for Choosing a Method for Determining the Index of Refraction and Dispersion of Glass
- 推荐标准
- INCITS 20-1967[S2010] Take-Up Reels for One-Inch Perforated Tape for Information Interchange (formerly ANSI X3.20-1967 (R2000))
- INCITS/ISO/IEC 14496-20:2008AM1:2009 [R2016] Information technology -- Coding of audio-visual objects -- Part 20: Lightweight Application Scene Representation (LASeR) and Simple Aggregation Format (SAF) AMENDMENT 1: Extensions to support SVGT1.2
- INCITS/ISO/IEC 14496-5:2001/AM 20:2009 [R2016] Information technology -- Coding of audio-visual objects -- Part 5: Reference software - Amendment 20: MPEG-1 and -2 on MPEG-4 reference software
- INCITS/ISO/IEC 2382-20:1990[R2011] Information Processing Systems Vocabulary Part 20: System Development (formerly ANSI/ISO/IEC 2382-20-1990)
- ASTM D8137-18(2023) Practice for Accelerated Aging of Leather
- ASTM D8138-23 Standard Specification for Preformed Silicone Joint Sealing System for Bridges
- ASTM D8139-23 Standard Specification for Semi-Rigid, Closed-Cell Polypropylene Foam, Preformed Expansion Joint Fillers for Concrete Paving and Structural Construction
- ASTM D814-95(2020) Standard Test Method for Rubber Property—Vapor Transmission of Volatile Liquids
- ASTM D8140-18(2023) Standard Guide for the Use of Foundry Sand in Asphalt Mixtures
- ASTM D8141-22 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments
- ASTM D8144-22 Standard Test Method for Separation and Determination of Aromatics, Nonaromatics, and FAME Fractions in Middle Distillates by Solid-Phase Extraction and Gas Chromatography
- ASTM D8148-22 Standard Test Method for Spectroscopic Determination of Haze in Fuels
- ASTM D8149-20 Standard Practice for Optimization, Calibration, and Validation of Ion Chromatographic Determination of Heteroatoms and Anions in Petroleum Products and Lubricants
- ASTM D8150-22 Standard Test Method for Determination of Organic Chloride Content in Crude Oil by Distillation Followed by Detection Using Combustion Ion Chromatography
- ASTM D8152-18 Standard Practice for Measuring Field Infiltration Rate and Calculating Field Hydraulic Conductivity Using the Modified Philip Dunne Infiltrometer Test