
【国外标准】 Standard Guide for Implementation of a Fleet Management System Network (Withdrawn 2015)
本网站 发布时间:
2024-02-28
- ASTM F1756-97a(2008)
- Withdrawn, No replacement
- 定价: 0元 / 折扣价: 0 元
- 在线阅读
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
Competent information management is essential for safe and productive operation and regulatory compliance. A short list of the functions affected includes decision aids for navigation, communications, ship handling, machinery control, cargo operations, maintenance and repair, personnel records, and environmental protection.The shipbuilding and shipping industries have identified a need to develop comprehensive standards and guides for implementing computer-based shipboard data management systems.The FMS may include single or multiple SITPs and single or multiple LITPs and provides the means to integrate shipboard and shoreside computer systems with multivendor connectivity, distributed processing, and electronic data interchange between noncompatible networks, computers, workstations, and peripherals and maintain databases, which promote safety of life at sea, protection of the environment, and operational efficiencies throughout the life cycle of the vessel/fleet. The FMS may incorporate satellite gateways to coastal communication hubs providing access to land-based networks, such as telephone lines, facsimile, e-mail, and expanded satellite services through land earth stations.The SITP can be configured to provide the ship’control center with access to local control centers, such as for cargo operations, which may be located on the main deck.This guide has provisions relevant to all components of the FMS platform including the ship earth station, interface devices for subsystems and administrative systems connected to or forming part of the network, communication services, and certain land-based facilities under the direct control of the ship’management.It is the intent of this guide to provide guidelines for the design and implementation of open client/server architecture for computer and communication networks for shipboard and shore-based applications.This guide is intended to assist vessel owners, designers, shipyards, equipment suppliers, and computer service providers in the development of contract technical specifications, which detail the services to be supported, performance required, and criteria for acceptance for specific FMS installations.1.1 This guide provides an overview and guide for the selection and implementation by shipowners and operators of a Fleet Management System (FMS) network of computer services in a client/server architecture (see Fig. 1). The FMS is based upon a wide area enterprise network consisting of an unspecified number of Shipboard Information Technology Platforms (SITPs) and one or more shoreside Land-Based Information Technology Platforms (LITPs), which provides management services for the shipping enterprise. The FMS can be understood as a computer system comprised of one or more LITPs and one or more SITPs. It can be characterized as mission critical 24 × 365 (24 h/day, 365 days/year).1.2 The SITP (see Fig. 1) provides a set of software services, including:1.2.1 Communications Services, to communicate between vessels and with shore via multiple wireless communication technologies;1.2.2 Data Acquisition Services, providing access to shipboard system data as required for use by other systems and management purposes; and,1.2.3 Executive Services, providing software process administration and control.1.2.4 In total, the SITP provides the capability for multiple shipboard computer systems to share data with each other and to communicate with shore-based management or other vessels or both.1.3 The SITP is understood to consist of integrated hardware, software, a data repository, and standardized procedures, which provide the ability to send, receive, process, transfer, and store data or messages in digital form in a common mode from shipboard systems or administrative utilities or both, and from designated sources outside the network, for example, systems accessed through wireless communication services, such as satellite, VHF, HF, and so forth. Shipboard systems include navigational, machinery control and monitoring, cargo control, communications, and so forth. The SITP also will provide the capability for the remote administration and maintenance of associated computer systems aboard the vessel.1.4 The SITP requires an underlying hardware and network infrastructure, including a shipboard computer local area network (LAN), file servers, workstations, wireless communications transceivers, cabling, other electronic and optical devices, video display units, keyboards, and so forth.1.5 The SITP also requires underlying system software providing network operating system (NOS) services, DBMS services, and other system software.1.6 There also is a layer of shipboard application systems, which are designed to capitalize on the FMS infrastructure to share data with other shipboard systems and management ashore. Those systems also would be able to capitalize on the remote management capabilities of the FMS.1.7 The LITP is an asset that can exchange operating and administrative data from individual ships and maintain a DBMS to support fleet management and other maritime applications. The LITP will support data repositories, file servers, workstations or personal computers (PCs), and a communication hub providing connectivity to distributed satellite services, VHF (very high frequency), HF/MF (high frequency/medium frequency), and land lines. The DBMS makes possible the development of knowledge-based “decision aids” by providing the ability to retrieve, process, and analyze operational data.1.8 This guide does not purport to address all the requirements for a SITP, which forms a path for data for direct control of the operation or condition of the vessel or the vessel subsystems.1.9 In all cases, it shall be possible for all units of navigation equipment resident on the Navigation Equipment Bus to operate and display essential operating data independently of the FMS.1.10 In all cases, it shall be possible for all units resident on the Control, Monitoring, and Alarm Bus to operate and display essential operating data independently of the FMS.1.11 In all cases, it shall be possible for all units resident on the Communications Bus to operate and display essential operating data independently of the FMS.1.12 Values shown in this guide are in SI units.1.13 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
标准号:
ASTM F1756-97a(2008)
标准名称:
Standard Guide for Implementation of a Fleet Management System Network (Withdrawn 2015)
英文名称:
Standard Guide for Implementation of a Fleet Management System Network (Withdrawn 2015)标准状态:
Withdrawn, No replacement-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 1546.1:2008 On-site domestic wastewater treatment units Septic tanks
- AS/NZS 1680.2.2:2008 Interior and workplace lighting Specific applications - Office and screen-based tasks
- AS/NZS 1680.2.3:2008 Interior and workplace lighting Specific applications - Educational and training facilities
- AS/NZS 1826:2008 Electrical equipment for explosive gas atmospheres - Special protection - Type of protection 's'
- AS/NZS 1891.1:2007/Amdt 2:2008 Industrial fall-arrest systems and devices Harness and ancillary equipment
- AS/NZS 2032:2006/Amdt 1:2008 Installation of PVC pipe systems
- AS/NZS 2033:2008/Amdt 2:2009 Installation of polyethylene pipe systems
- AS/NZS 2269.1:2008 Plywood - Structural Determination of structural properties - Test methods
- AS/NZS 2293.2:1995/Amdt 2:2008 Emergency escape lighting and exit signs for buildings Inspection and maintenance
- AS/NZS 2350.16:2006 (R2016)/Amdt 1:2008 Methods of testing portland, blended and masonry cements Determination of air content of masonry cement
- AS/NZS 2350.3:2006 (R2016)/Amdt 1:2008 Methods of testing portland, blended and masonry cements Normal consistency
- AS/NZS 2350.4:2006 (R2016)/Amdt 1:2008 Methods of testing portland, blended and masonry cements Setting time
- AS/NZS 2843.1:2006 (R2016)/Amdt 2:2008 Timber preservation plants Timber preservation plant site design
- AS/NZS 3001:2008/Amdt 1:2012 Electrical installations - Transportable structures and vehicles including their site supplies
- AS/NZS 3002:2008 Electrical installations - Shows and carnivals