【国外标准】 Standard Test Method for Determination of Effective Boron-10 Areal Density in Aluminum Neutron Absorbers using Neutron Attenuation Measurements
本网站 发布时间:
2024-02-28

适用范围:
5.1 The typical use of this test method is determination of 10B areal density in aluminum neutron absorber materials used to control criticality in systems such as: spent nuclear fuel dry storage canisters, transfer/transport nuclear fuel containers, spent nuclear fuel pools, and fresh nuclear fuel transport containers.5.2 Areal density measurements are also used in the investigation of the uniformity in 10B spatial distribution.5.3 The expected users of this standard include designers, suppliers, neutron absorber users, testing labs, and consultants in the field of nuclear criticality analysis.5.4 Another known method used to determine areal density of 10B in aluminum neutron absorbers is an analytical chemical method as mentioned in Practice C1671. However, the analytical chemical method does not measure the “effective” 10B areal density as measured by neutron attenuation.1.1 This test method is intended for quantitative determination of effective boron-10 (10B) areal density (mass per area of 10B, usually measured in grams-10B/cm2 ) in aluminum neutron absorbers. The attenuation of a thermal neutron beam transmitted through an aluminum neutron absorber is compared to attenuation values for calibration standards allowing determination of the effective 10B areal density. This test is typically performed in a laboratory setting. This method is valid only under the following conditions:1.1.1 The absorber contains 10B in an aluminum or aluminum alloy matrix.1.1.2 The primary neutron absorber is 10B.1.1.3 The test specimen has uniform thickness.1.1.4 The test specimen has a testing surface area at least twice that of the thermal neutron beam’s surface cross-sectional area.1.1.5 The calibration standards of uniform composition span the range of areal densities being measured.1.1.6 The areal density is between 0.001 and 0.080 grams of 10B per cm2.1.1.7 The thermalized neutron beam is derived from a fission reactor, sub-critical assembly, accelerator or neutron generator.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM E2971-16(2020)
标准名称:
Standard Test Method for Determination of Effective Boron-10 Areal Density in Aluminum Neutron Absorbers using Neutron Attenuation Measurements
英文名称:
Standard Test Method for Determination of Effective Boron-10 Areal Density in Aluminum Neutron Absorbers using Neutron Attenuation Measurements标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS/NZS 2350.16:2006 (R2016)/Amdt 1:2008 Methods of testing portland, blended and masonry cements Determination of air content of masonry cement
- AS/NZS 3350.2.16:1996/Amdt 3:2007 Safety of household and similar electrical appliances Particular requirements - Food waste disposers (IEC 60335-2-15:1994, MOD)
- AS/NZS 3580.16:2014 Methods for sampling and analysis of ambient air Determination of polycyclic aromatic hydrocarbons (PAH)
- AS/NZS 3750.16:1998 (R2013) Paints for steel structures Waterborne primer and paint for galvanized, zinc/aluminium alloy-coated and zinc-primed steel
- AS/NZS 3905.16:1998 Quality system guidelines Guidelines to quality in project management
- AS/NZS 4387.16:1996 Domestic kitchen assemblies - Methods of test Determination of calibration of drawer slamming apparatus
- AS/NZS 4524.16:1998 Bonded abrasive products - Dimensions Grinding wheels for cutting-off on an angle grinder
- AS/NZS 61000.4.16:2002/Amdt 1:2012 Electromagnetic compatibility (EMC) Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz
- AS/NZS 61558.2.16:2010 (IEC TEXT)/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS 61558.2.16:2010/Amdt 1:2010 Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1 100 V Particular requirements for switch mode power supply units and transformers for switch mode power supply units
- AS/NZS CISPR 16.1.1:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.1:2006 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Measuring apparatus
- AS/NZS CISPR 16.1.2:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Conducted disturbances
- AS/NZS CISPR 16.1.3:2004 Specification for radio disturbance and immunity measuring apparatus and methods Radio disturbance and immunity measuring apparatus - Disturbance power
- AS/NZS CISPR 16.1.4:2004 (2nd Edition) Specification for radio disturbance and immunity measuring apparatus and methods - Radio disturbance and immunity measuring apparatus - Ancillary equipment - Radiated disturbances