【国外标准】 Standard Practice for Use of Calorimetric Dosimetry Systems for Dose Measurements and Routine Dosimetry System Calibration in Electron Beams
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
4.1 This practice is applicable to the use of calorimetric dosimetry systems for the measurement of absorbed dose in electron beams, the qualification of electron irradiation facilities, periodic checks of operating parameters of electron irradiation facilities, and calibration of other dosimetry systems in electron beams. Calorimetric dosimetry systems are most suitable for dose measurement at electron irradiation facilities utilizing conveyor systems for transport of product during irradiation.NOTE 1: For additional information on calorimetric dosimetry system operation and use, see ICRU Report 80. For additional information on the use of dosimetry in electron accelerator facilities, see ISO/ASTM 51649, and ICRU Reports 34 and 35, and Refs (1-3).64.2 The calorimetric dosimetry systems described in this practice are not primary standard dosimetry systems. The calorimeters are classified as Type II dosimeters (ISO/ASTM 52628). They might be used as internal standards at an electron beam irradiation facility, including being used as transfer standard dosimetry systems for calibration of other dosimetry systems, or they might be used as routine dosimeters. The calorimetric dosimetry systems are calibrated by comparison with transfer standard dosimeters.4.3 The dose measurement is based on the measurement of the temperature rise (dosimeter response) in an absorber (calorimetric body) irradiated by an electron beam. Different absorbing materials are used, but the response is usually defined in terms of dose to water.NOTE 2: The calorimetric bodies of the calorimeters described in this practice are made from low atomic number materials. The electron fluences within these calorimetric bodies are almost independent of energy when irradiated with electron beams of 1.5 MeV or higher, and the mass collision stopping powers are approximately the same for these materials.4.4 The absorbed dose in other materials irradiated under equivalent conditions can be calculated. Procedures for making such calculations are given in ASTM Practices E666 and E668, and Ref (1).4.4.1 Calorimeters for use at industrial electron accelerators have been constructed using graphite, polystyrene or a Petri dish filled with water as the calorimetric body (4-10). The thickness of the calorimetric body should be less than the range of the incident electrons.4.4.2 Polymeric materials other than polystyrene might also be used for calorimetric measurements. Polystyrene is used because it is known to be resistant to radiation (11) and because almost no exo- or endothermic reactions take place (12).1.1 This practice covers the preparation and use of semi-adiabatic calorimetric dosimetry systems for measurement of absorbed dose and for calibration of routine dosimetry systems when irradiated with electrons for radiation processing applications. The calorimeters are either transported by a conveyor past a scanned electron beam or are stationary in a broadened beam.1.2 This document is one of a set of standards that provides recommendations for properly implementing dosimetry in radiation processing, and describes a means of achieving compliance with the requirements of ISO/ASTM Practice 52628 for a calorimetric dosimetry system. It is intended to be read in conjunction with ISO/ASTM Practice 52628.1.3 The calorimeters described in this practice are classified as Type II dosimeters on the basis of the complex effect of influence quantities. See ISO/ASTM Practice 52628.1.4 This practice applies to electron beams in the energy range from 1.5 to 12 MeV.1.5 The absorbed dose range depends on the calorimetric absorbing material and the irradiation and measurement conditions. Minimum dose is approximately 100 Gy and maximum dose is approximately 50 kGy.1.6 The average absorbed-dose rate range shall generally be greater than 10 Gy·s-1.1.7 The temperature range for use of these calorimetric dosimetry systems depends on the thermal resistance of the calorimetric materials, on the calibration range of the temperature sensor, and on the sensitivity of the measurement device.1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.1.9 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM ISO/ASTM51631-20
标准名称:
Standard Practice for Use of Calorimetric Dosimetry Systems for Dose Measurements and Routine Dosimetry System Calibration in Electron Beams
英文名称:
Standard Practice for Use of Calorimetric Dosimetry Systems for Dose Measurements and Routine Dosimetry System Calibration in Electron Beams标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 其它标准
- 上一篇: ASTM ISO/ASTM51608-15(2022) Standard Practice for Dosimetry in an X-Ray (Bremsstrahlung) Facility for Radiation Processing at Energies between 50 keV and 7.5 MeV
- 下一篇: ASTM ISO/ASTM51649-15 Standard Practice for Dosimetry in an Electron Beam Facility for Radiation Processing at Energies Between 300 keV and 25 MeV
- 推荐标准
- AS ISO 10006-2003 Quality management systems - Guidelines for quality management in projects
- AS ISO 10014-2007 Quality management systems - Guidelines for realizing financial and economic benefits
- AS ISO 10993.10-2002 Biological evaluation of medical devices Tests for irritation and sensitization
- AS ISO 10993.12-2002 Biological evaluation of medical devices Sample preparation and reference materials
- AS ISO 11137-2002 Sterilization of health care products - Requirements for validation and routine control - Radiation sterilization
- AS ISO 12647.1:2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Parameters and measurement methods
- AS ISO 12647.2-2008 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Offset lithographic processes
- AS ISO 12647.7:2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Proofing processes working directly from digital data
- AS ISO 12647.8-2012 Graphic technology - Process control for the production of half-tone colour separations, proof and production prints Validation print processes working directly from digital data
- AS ISO 13485-2003 Medical devices - Quality management systems - Requirements for regulatory purposes
- AS ISO 13488-2002 Quality systems - Medical devices - Particular requirements for the application of ISO 9002
- AS ISO 13916-2003 Welding - Guide on the measurement of preheating temperature, interpass temperature and preheat maintenance temperature
- AS ISO 140.8-2006 Acoustics - Measurement of sound insulation in buildings and of building elements Laboratory measurements of the reduction of transmitted impact noise by floor coverings on a heavyweight standard floor
- AS ISO 14021(Int)-1998 Environmental labels and declarations - Self-declared environmental claims
- AS ISO 14155-2002 Clinical investigation of medical devices