【国外标准】 Standard Practice for Evaluating Compatibility of Binary Mixtures of Lubricating Greases
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 The compatibility of greases can be important for users of grease-lubricated equipment. It is well known that the mixing of two greases can produce a substance markedly inferior to either of its constituent materials. One or more of the following can occur. A mixture of incompatible greases most often softens, sometimes excessively. Occasionally, it can harden. In extreme cases, the thickener and liquid lubricant will completely separate. Bleeding can be so severe that the mixed grease will run out of an operating bearing. Excessive syneresis can occur, forming pools of liquid lubricant separated from the grease. Dropping points can be reduced to the extent that grease or separated oil runs out of bearings at elevated operating temperatures. Such events can lead to catastrophic lubrication failures.5.1.1 Because of such occurrences, equipment manufacturers recommend completely cleaning the grease from equipment before installing a different grease. Service recommendations for grease-lubricated equipment frequently specify the caveat–do not mix greases under any circumstances. Despite this admonition, grease mixing will occur and, at times, cannot be avoided. In such instances, it would be useful to know whether the mixing of two greases could lead to inadequate lubrication with disastrous consequences. Equipment users most often do not have the resources to evaluate grease compatibility and must rely on their suppliers. Mixing of greases is a highly imprudent practice. Grease and equipment manufacturers alike recognize such practices will occur despite all warnings to the contrary. Thus, both users and suppliers have a need to know the compatibility characteristics of the greases in question.5.2 There are two approaches to evaluating the compatibility of grease mixtures. One is to determine whether such mixtures meet the same specification requirements as the constituent components. This approach is not addressed by this practice. Instead, this practice takes a specification-independent approach; it describes the evaluation of compatibility on a relative basis using specific test methods.5.2.1 Three test methods are used because fewer are not sufficiently definitive. For example, in one study, using 100 000-stroke worked penetration for evaluation, 62 % of the mixtures were judged to be compatible.5 In a high-temperature storage stability study, covering a broader spectrum of grease types, only one-third of the mixtures were compatible.5 These studies used different criteria to judge compatibility.5.2.2 Compatibility cannot be predicted with certainty from foreknowledge of grease composition. Generally, greases having the same or similar thickener types will be compatible. Uncommonly, even greases of the same type, although normally compatible when mixed, can be incompatible because of incompatible additive treatments. Thus, compatibility needs to be judged on a case-by-case basis.5.3 Two constituent greases are blended in specific ratios. A 50:50 mixture simulates a ratio that might be experienced when one grease (Grease A) is installed in a bearing containing a previously installed, different grease (Grease B), and no attempt is made to flush out Grease B with Grease A. The 10:90 and 90:10 ratios are intended to simulate ratios that might occur when attempts are made to flush out Grease B with Grease A.NOTE 1: Some companies evaluate 25:75 and 75:25 ratio mixtures instead of 10:90 and 90:10 ratio mixtures. But, the latter two ratios, which are prescribed by this practice, are considered more representative of the flushing practice described in 5.3.5.3.1 Incompatibility is most often revealed by the evaluation of 50:50 mixtures. However, in some instances 50:50 mixtures are compatible and more dilute ratios are incompatible. (See Appendix X1 and Meade.6)5.4 Compatibility information can be used in product information literature supplied with specific greases. It can be used also in literature describing lubrication practices and equipment maintenance.1.1 This practice covers a protocol for evaluating the compatibility of one or three binary mixtures of lubricating greases by comparing their properties or performance relative to those of the neat greases comprising the mixture.1.2 Three properties are evaluated in a primary testing protocol using standard test methods: (1) dropping point by Test Method D566 (or Test Method D2265); (2) shear stability by Test Methods D217, 100 000–stroke worked penetration; and (3) storage stability at elevated-temperature by change in 60-stroke penetration (Test Method D217). For compatible mixtures (those passing all primary testing), a secondary (nonmandatory) testing scheme is suggested when circumstances indicate the need for additional testing.1.3 Sequential or concurrent testing is continued until the first failure. If any mixture fails any of the primary tests, the greases are incompatible. If all mixtures pass the three primary tests, the greases are considered compatible.1.4 This practice applies only to lubricating greases having characteristics suitable for evaluation by the suggested test methods. If the scope of a specific test method limits testing to those greases within a specified range of properties, greases outside that range cannot be tested for compatibility by that test method. An exception to this would be when the tested property of the neat, constituent greases is within the specified range, but the tested property of a mixture is outside the range because of incompatibility.1.5 This practice does not purport to cover all test methods that could be employed.1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific safety information, see 7.2.3.
标准号:
ASTM D6185-11(2017)
标准名称:
Standard Practice for Evaluating Compatibility of Binary Mixtures of Lubricating Greases
英文名称:
Standard Practice for Evaluating Compatibility of Binary Mixtures of Lubricating Greases标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- INCITS 11-1990 (S2017) General Purpose Paper Cards for Information Processing
- INCITS 111-1986 (S2017) Information Systems - Optical Character Recognition (OCR) - Matrix Character Sets for OCR-M
- INCITS 115-1984 (S2017) Unformatted 80 Megabyte Trident Pack for Use at 370 TPI and 6000 BPI - Physical, Mechanical and Magnetic Characteristics
- INCITS 116-1986 (S2017) Recorded Magnetic Tape Cartridge for Information Interchange 4-Track, Serial 0.250 in (6.30 mm) 6400 BPI (252 BPMM) Inverted Modified Frequency Modulation Encoded
- INCITS 117-1984 (S2017) Printable/Image Areas for Text and Facsimile Communication Equipment
- INCITS 119-1984 (S2017) Contact Start/Stop Storage Disk, 158361 Flux Transitions per Track, 8.268 Inch (210 mm) Outer Diameter and 3.937 Inch (100 mm) Inner Diameter
- INCITS 120-1984 (S2017) Contact Start/Stop Storage Disk, 95840 Flux Transitions per Track, 7.874 Inch (200 mm) Outer Diameter and 2.500 Inch (63.5 mm) Inner Diameter
- INCITS 126-1986 (S2017) One- and Two-Sided Double Density Unformatted 5.25 Inch (130 mm) 96 Tracks per Inch (3.8 Tracks per mm) Flexible Disk Cartridge - General, Physical, and Magnetic Requirements for 7958 BPR Use
- INCITS 149-1986 (R2017) Financial Transaction Card Formsets - Location of Imprinted Information
- INCITS 150-1987 (S2017) Business Machines, Data Processing Equipment and Business Forms - Character and Line Spacing
- INCITS 151-1987 (S2017) Bond Papers and Index Bristols - Common Sheet Sizes
- INCITS 152-1987 (S2017) Specifications for Noncarbonized, Single-Ply, Adding Machine Paper Rolls
- INCITS 163-1988 (S2017) Information Systems - Contact Start/Stop Metallic Film Storage Disk - 83,333 Flux Transitions Per Track, 130-mm (5.118-in) Outer Diameter and 40-mm (1.575-in) Inner Diameter
- INCITS 179-1990 (S2017) 95-mm Diameter Rigid Digital Recording Disk
- INCITS 182-1990 (S2017) Guideline for Bar Code Print Quality