【国外标准】 Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
本网站 发布时间:
2024-02-28
开通会员免费在线看70000余条国内标准,赠送文本下载次数,单本最低仅合13.3元!还可享标准出版进度查询、定制跟踪推送、标准查新等超多特权!  
查看详情>>

适用范围:
5.1 This is not a routine test. The values recorded are applicable only to the sewer being tested and at the time of testing.1.1 This practice covers procedures for testing installed precast concrete pipe sewer lines using either water infiltration or exfiltration acceptance limits to demonstrate the integrity of the installed materials and construction procedure.1.2 This practice is the inch-pound companion to Practice C969M; therefore, no SI equivalents are presented in the practice.NOTE 1: The owner shall specify the following: who will conduct, observe, and furnish labor, furnish material and measuring devices, and pay for the tests; who is responsible for determining local groundwater conditions; and which test is to be conducted, that is, an infiltration test or an exfiltration test.NOTE 2: The user of this practice is advised that test criteria presented in this practice are similar to those in general use. Pipe, 24-in. diameter or larger, may be accepted by visual inspection when testing for infiltration.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
标准号:
ASTM C969-19
标准名称:
Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines
英文名称:
Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines标准状态:
Active-
发布日期:
-
实施日期:
出版语种:
- 推荐标准
- AS 1012.19-1988 Methods of testing concrete Accelerated curing of concrete compression test specimens (laboratory or field) - Hot water and warm water methods
- AS 1180 (Pt 9A to 9C)-1973 Methods of test for hose made from elastomeric materials - Third Group Methods 9A, 9B, 9C
- AS 1418.19-2007 Cranes, hoists and winches Telescopic handlers
- AS 1678.3C1-1987 Emergency procedure guide - Transport Group text EPGs for Class 3 substances - Flammable liquids - Flammable liquid of lesser hazard
- AS 1684.3 C1 Supp 1-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 1: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F5 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 10-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 10: Timber framing span tables - Wind classification C1 - Unseasoned softwood - Stress Grade F5 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 11-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 11: Timber framing span tables - Wind classification C1 - Unseasoned softwood - Stress Grade F7 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 12-2010 Residential timber-framed construction Cyclonic areas - C1 Supplement 12: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F8 (Supplement to AS 1684.3-2010)
- AS 1684.3 C1 Supp 13-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 13: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F11 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 14-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 14: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F14 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 15-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 15: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F17 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 15-2006 Residential timber-framed construction Cyclonic areas - C1 Supplement 15: Timber framing span tables - Wind classification C1 - Unseasoned hardwood - Stress Grade F17 (Supplement to AS 1684.3-2006)
- AS 1684.3 C1 Supp 2-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 2: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F7 (Supplement to AS 1684.3-1999)
- AS 1684.3 C1 Supp 2-2010 Residential timber-framed construction Cyclonic areas - C1 Supplement 2: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F7 (Supplement to AS 1684.3 - 2010)
- AS 1684.3 C1 Supp 3-1999 Residential timber-framed construction Cyclonic areas - C1 Supplement 3: Timber framing span tables - Wind classification C1 - Seasoned softwood - Stress Grade F8 (Supplement to AS 1684.3-1999)